⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Inverters

SolaX Power X1-FIT-3.7-W

Побудувати систему з цим продуктом

Official manufacturer GLOBAL перевірено 25 вересня 2026 р.

Identity

category inverters
ean —
firmware {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'}
generation G4
manufacturer SolaX Power
market_version —
model X1-FIT-3.7-W
mpn —
product_family X1-FIT
product_status —
product_type AC-coupled battery retrofit inverter
region GLOBAL
release_year —
series X1-FIT G4
sku —

Electrical

ac_connection Single phase
ac_voltage_range 180 V to 270 V
battery_capacity_range_kwh —
battery_communication CAN / RS485
battery_max_charge_current_a 30
battery_max_charge_power_w —
battery_max_discharge_current_a —
battery_max_discharge_power_w —
battery_nominal_battery_voltage_v —
battery_type Lithium batteries
battery_voltage_range_v 80 V to 480 V
eps_peak_power 5000 VA, 10 s
eps_phase Single phase
eps_rated_power_va 3680
eps_switchover_time_ms internal switch < 10; external switch < 100
eps_voltage 230 VAC
european_efficiency_pct —
external_transfer_switch_required —
frequency_range_hz —
inrush_current —
max_ac_active_power_w —
max_ac_current_a 16
max_apparent_power_va 3680
max_backfeed_current_a —
max_dc_input_power_w —
max_dc_voltage_v —
max_efficiency_pct —
max_input_current_per_mppt_a —
max_output_fault_current_a —
max_short_circuit_current_per_mppt_a —
mppt_efficiency_pct —
mppt_voltage_range_v —
night_self_consumption_w —
nominal_ac_voltage 220 / 230 / 240 V
nominal_dc_voltage_v —
nominal_frequency_hz 50
number_of_mppt —
official_datasheet_url https://www.solaxpower.com/uploads/file/x1-retrofit-g4-datasheet-en.pdf
SolaX X1-FIT G4 Datasheet EN (covers X1-FIT-3.7/4.6/5.0/6.0/7.5-W)
official_product_url https://in.solaxpower.com/x1-retro-fit/
SolaX X1-FIT G4 Datasheet EN (covers X1-FIT-3.7/4.6/5.0/6.0/7.5-W)
parallel_capability —
phase_count 1
power_factor_range 0.8 leading to 0.8 lagging
rated_ac_power_w 3680
rated_mppt_voltage_range_v —
startup_voltage_v —
strings_per_mppt —
thd_pct 2

Physical / mechanical

ac_terminal —
cooling Natural Cooling
dc_connector —
depth_mm 181
dimensions_mm 482 x 417 x 181
display —
enclosure_material —
height_mm 417
mounting —
noise_db 30
weight_kg 23
width_mm 482

Installation

cable_requirements —
commissioning —
installation_angle —
mounting_clearances —
torque —

Environment

ingress_protection IP65
max_altitude_m 3000
operating_temperature_c -35 to +60 (derating from +45)
pollution_degree —
protective_class —
relative_humidity_pct 0 to 100 (no condensation)
storage_temperature_c -40 to +65

Interfaces & connectors

app —
communication ['Meter/CT', 'RS485 (external control)', 'Pocket series', 'DRM', 'USB', 'CAN']
dry_contact —
meter_interface Meter/CT
monitoring_portal SolaXCloud
protocols —

Protection

anti_islanding Active anti-islanding method
arc_fault —
dc_switch —
insulation_monitoring —
overvoltage_category —
rcmu Residual current detection
reverse_polarity —
surge_protection_ac AC SPD protection
surge_protection_dc —

Certifications

standards ['EN/IEC 62109-1/-2', 'VDE-AR-N 4105', 'G99', 'G98', 'AS/NZS 4777', 'EN 50549', 'CEI 0-21', 'C10/11', 'IEC 61727', 'RD 1699', 'NRS 097-2-1', 'PEA/MEA', 'VFR 2019', 'PPDS']

Warranty & service

conditions —
extension_options —
standard_years —

Документи

datasheet SolaX X1-FIT G4 Datasheet EN (covers X1-FIT-3.7/4.6/5.0/6.0/7.5-W)
product_page SolaX X1-FIT (X1 RetroFit) G4 product page
product_page SolaX X1-FIT G4 (X1 Retro Fit) - product page
user-manual SolaX X1-Fit G4 User Manual rev Version 03 (V3.0)

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

4.2 Batterybattery DC input present
Max. apparent powerread 1: 5000 VA in the 3.7-W column, 9200 VA in the 5.0-W / 6.0-W / 7.5-W columns; read 2: 9200 VA as one cell merged across all nine columns
Max. battery charge efficiency / Max. battery discharge efficiency97.0%
Max. battery charge efficiency / max. battery discharge efficiency97.0 % / 97.0 %
Max. discharge currentread 1: '30 A' shared across all models; read 2: 'varies by model configuration, multiple cells' with no figures given
Nominal frequency50 / 60 Hz
Scope of validity / technical-data column headersX1-Fit-3.7-W, X1-Fit-3.7-M, X1-Fit-5.0-W, X1-Fit-5.0-M, X1-Fit-6.0-W, X1-Fit-6.0-M, X1-Fit-7.5-W, X1-Fit-7.5-M, X1-Fit-5.0K-W
THD< 2 %
battery.communicationCAN / RS485
battery.max_charge_current_a30
battery.max_charge_power_wUNKNOWN
battery.max_discharge_current_aUNKNOWN
battery.max_discharge_power_wUNKNOWN
battery.nominal_battery_voltage_vUNKNOWN
builder_completenesspartial
identity.region_as_printedEU/global