SolaX Power X1-FIT-7.5-W
Official manufacturer GLOBAL перевірено 25 вересня 2026 р.
Identity
| category | inverters |
| ean | — |
| firmware | {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'} |
| generation | G4 |
| manufacturer | SolaX Power |
| market_version | — |
| model | X1-FIT-7.5-W |
| mpn | — |
| product_family | X1-FIT |
| product_status | — |
| product_type | AC-coupled battery retrofit inverter |
| region | GLOBAL |
| release_year | — |
| series | X1-FIT G4 |
| sku | — |
Electrical
| ac_connection | Single phase |
| ac_voltage_range | 180 V to 270 V |
| battery_capacity_range_kwh | — |
| battery_communication | CAN / RS485 |
| battery_max_charge_current_a | 30 |
| battery_max_charge_power_w | — |
| battery_max_discharge_current_a | — |
| battery_max_discharge_power_w | — |
| battery_nominal_battery_voltage_v | — |
| battery_type | Lithium batteries |
| battery_voltage_range_v | 80 V to 480 V |
| eps_peak_power | 9000 VA, 10 s |
| eps_phase | Single phase |
| eps_rated_power_va | 7500 |
| eps_switchover_time_ms | internal switch < 10; external switch < 100 |
| eps_voltage | 230 VAC |
| european_efficiency_pct | — |
| external_transfer_switch_required | — |
| frequency_range_hz | — |
| inrush_current | — |
| max_ac_active_power_w | — |
| max_ac_current_a | 32.6 |
| max_apparent_power_va | 7500 |
| max_backfeed_current_a | — |
| max_dc_input_power_w | — |
| max_dc_voltage_v | — |
| max_efficiency_pct | — |
| max_input_current_per_mppt_a | — |
| max_output_fault_current_a | — |
| max_short_circuit_current_per_mppt_a | — |
| mppt_efficiency_pct | — |
| mppt_voltage_range_v | — |
| night_self_consumption_w | — |
| nominal_ac_voltage | 220 / 230 / 240 V |
| nominal_dc_voltage_v | — |
| nominal_frequency_hz | 50 |
| number_of_mppt | — |
| official_datasheet_url |
https://www.solaxpower.com/uploads/file/x1-retrofit-g4-datasheet-en.pdf
SolaX X1-FIT G4 Datasheet EN (covers X1-FIT-3.7/4.6/5.0/6.0/7.5-W)
|
| official_product_url |
https://in.solaxpower.com/x1-retro-fit/
SolaX X1-FIT G4 Datasheet EN (covers X1-FIT-3.7/4.6/5.0/6.0/7.5-W)
|
| parallel_capability | — |
| phase_count | 1 |
| power_factor_range | 0.8 leading to 0.8 lagging |
| rated_ac_power_w | 7500 |
| rated_mppt_voltage_range_v | — |
| startup_voltage_v | — |
| strings_per_mppt | — |
| thd_pct | 2 |
Physical / mechanical
| ac_terminal | — |
| cooling | Smart Cooling |
| dc_connector | — |
| depth_mm | 181 |
| dimensions_mm | 482 x 417 x 181 |
| display | — |
| enclosure_material | — |
| height_mm | 417 |
| mounting | — |
| noise_db | 45 |
| weight_kg | — |
| width_mm | 482 |
Installation
| cable_requirements | — |
| commissioning | — |
| installation_angle | — |
| mounting_clearances | — |
| torque | — |
Environment
| ingress_protection | IP65 |
| max_altitude_m | 3000 |
| operating_temperature_c | -35 to +60 (derating from +45) |
| pollution_degree | — |
| protective_class | — |
| relative_humidity_pct | 0 to 100 (no condensation) |
| storage_temperature_c | -40 to +65 |
Interfaces & connectors
| app | — |
| communication | ['Meter/CT', 'RS485 (external control)', 'Pocket series', 'DRM', 'USB', 'CAN'] |
| dry_contact | — |
| meter_interface | Meter/CT |
| monitoring_portal | SolaXCloud |
| protocols | — |
Protection
| anti_islanding | Active anti-islanding method |
| arc_fault | — |
| dc_switch | — |
| insulation_monitoring | — |
| overvoltage_category | — |
| rcmu | Residual current detection |
| reverse_polarity | — |
| surge_protection_ac | AC SPD protection |
| surge_protection_dc | — |
Certifications
| standards | ['EN/IEC 62109-1/-2', 'VDE-AR-N 4105', 'G99', 'G98', 'AS/NZS 4777', 'EN 50549', 'CEI 0-21', 'C10/11', 'IEC 61727', 'RD 1699', 'NRS 097-2-1', 'PEA/MEA', 'VFR 2019', 'PPDS'] |
Warranty & service
| conditions | — |
| extension_options | — |
| standard_years | — |
Документи
product_page
SolaX X1-FIT (X1 RetroFit) G4 product page
product_page
SolaX X1-FIT G4 (X1 Retro Fit) - product page
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| 4.2 Battery | battery DC input present |
| Max. apparent power | read 1: 5000 VA in the 3.7-W column, 9200 VA in the 5.0-W / 6.0-W / 7.5-W columns; read 2: 9200 VA as one cell merged across all nine columns |
| Max. battery charge efficiency / Max. battery discharge efficiency | 97.0% |
| Max. battery charge efficiency / max. battery discharge efficiency | 97.0 % / 97.0 % |
| Max. discharge current | read 1: '30 A' shared across all models; read 2: 'varies by model configuration, multiple cells' with no figures given |
| Net weight | read 1: '27-28 kg' for the 7.5-W column; read 2: '23 kg' merged across all columns |
| Nominal frequency | 50 / 60 Hz |
| Scope of validity / technical-data column headers | X1-Fit-3.7-W, X1-Fit-3.7-M, X1-Fit-5.0-W, X1-Fit-5.0-M, X1-Fit-6.0-W, X1-Fit-6.0-M, X1-Fit-7.5-W, X1-Fit-7.5-M, X1-Fit-5.0K-W |
| THD | < 2 % |
| battery.communication | CAN / RS485 |
| battery.max_charge_current_a | 30 |
| battery.max_charge_power_w | UNKNOWN |
| battery.max_discharge_current_a | UNKNOWN |
| battery.max_discharge_power_w | UNKNOWN |
| battery.nominal_battery_voltage_v | UNKNOWN |
| builder_completeness | partial |
| identity.region_as_printed | EU/global |