Voltronic Power (MPP Solar) Axpert King 5KVA (48V)
Official manufacturer UNKNOWN (230 VAC / 50-60 Hz product) перевірено 22 вересня 2026 р.
Identity
| brand | Axpert King |
| category | inverters |
| ean | — |
| generation | Axpert King (first generation; superseded in the current catalogue by Axpert King II / Axpert King IP52) |
| manufacturer | Voltronic Power (MPP Solar) |
| market_version | — |
| model | Axpert King 5KVA (48V) |
| mpn | — |
| product_family | Axpert King 3KVA/5KVA |
| product_revision | — |
| product_status | — |
| product_status_detail | UNKNOWN — as of 2026-09-02 the Axpert King 3KVA/5KVA product-detail page (https://voltronicpower.com/en-US/Product/Detail/Axpert-King-3KVA-5KVA) redirects to the Voltronic Power homepage and the model no longer appears in the site's Off-Grid Inverter menu (which now lists Axpert King IP52 and Axpert King II TWIN). The brochure and manual PDFs are still served. Treated as evidence of withdrawal, not as a documented status. |
| region | — |
| release_year | — |
| sku | — |
Electrical
| ac_coupling_support | — |
| ac_input_voltage_range_max_v |
280
Axpert King Off-Grid Inverter — brochure / datasheet
|
| ac_input_voltage_range_min_v |
110
Axpert King Off-Grid Inverter — brochure / datasheet
|
| backup_eps_output_support | True |
| battery_nominal_voltage_v |
48
Axpert King Off-Grid Inverter — brochure / datasheet
|
| battery_support | True |
| battery_supported |
True
Axpert King Off-Grid Inverter — brochure / datasheet
|
| battery_type | Lead-acid / Lithium (BMS via reserved RS485/CAN-BUS/RS232 port) |
| battery_voltage_class | LV |
| battery_voltage_max_v | 48 |
| battery_voltage_min_v | — |
| communication_can | True |
| communication_ethernet | — |
| communication_rs485 | True |
| communication_wifi | — |
| ct_support | — |
| float_charge_voltage_v |
54
Axpert King Off-Grid Inverter — brochure / datasheet
|
| generator_input_support | — |
| grid_certifications | — |
| grid_export_control | — |
| home_assistant_integration | — |
| max_ac_charge_current_a |
60
Axpert King Off-Grid Inverter — brochure / datasheet
|
| max_ac_power_kw | 10 |
| max_battery_charge_current_a | 140 (combined solar + AC charging, per brochure) |
| max_battery_charge_power_kw | — |
| max_battery_discharge_current_a | — |
| max_charge_current_a |
140
Axpert King Off-Grid Inverter — brochure / datasheet
|
| max_dc_voltage_v | 145 |
| max_input_current_per_mppt_a | — |
| max_parallel_units |
9
Axpert King Off-Grid Inverter — brochure / datasheet
|
| max_pv_array_power_w |
4000
Axpert King Off-Grid Inverter — brochure / datasheet
|
| max_pv_input_power_w | 4000 |
| max_pv_input_voltage_v |
145
Axpert King Off-Grid Inverter — brochure / datasheet
|
| max_short_circuit_current_per_mppt_a | — |
| max_solar_charge_current_a |
80
Axpert King Off-Grid Inverter — brochure / datasheet
|
| modbus_rtu | — |
| modbus_tcp | — |
| mppt_max_voltage_v | 115 |
| mppt_min_voltage_v | 60 |
| nominal_ac_input_voltage_v |
230
Axpert King Off-Grid Inverter — brochure / datasheet
|
| nominal_grid_voltage_v |
230
Axpert King Off-Grid Inverter — brochure / datasheet
|
| num_mppt | — |
| officially_supported_battery_brands | — |
| peak_efficiency_battery_mode_percent |
90
Axpert King Off-Grid Inverter — brochure / datasheet
|
| peak_efficiency_line_mode_percent |
93
Axpert King Off-Grid Inverter — brochure / datasheet
|
| phase_type | single-phase |
| pv_inputs_per_mppt | — |
| rated_ac_power_kw | 5 |
| rated_ac_power_w |
5000
Axpert King Off-Grid Inverter — brochure / datasheet
|
| rated_apparent_power_va |
5000
Axpert King Off-Grid Inverter — brochure / datasheet
|
| smart_meter_support | — |
| solar_charger_type |
MPPT
Axpert King Off-Grid Inverter — brochure / datasheet
|
| startup_voltage_v | — |
| sunspec_support | — |
| topology | off-grid |
Physical / mechanical
| bracket_dimensions_mm | — |
| cable_entry_positions | — |
| cable_gland_sizes | — |
| depth_mm | 140 |
| enclosure_material | — |
| height_mm | 525 |
| housing_color | — |
| mounting_bolt_size |
M4 or M5 (manual: 'three screws. It's recommended to use M4 or M5 screws')
Axpert King 3KW/5KW Inverter/Charger User Manual (Version 1.0) — manual p.4, 'three screws. It's recommended to use M4 or M5 screws'
|
| mounting_hole_diameter_mm | — |
| mounting_hole_spacing_mm | — |
| mounting_type | ['wall'] |
| screw_sizes | M4 / M5 wall-mount screws |
| shipping_weight_kg | — |
| terminal_locations | — |
| torque_specs |
Battery ring terminals 2-3 Nm; AC input/output wiring (5KW) 1.4-1.6 Nm; PV terminals 1.2-1.6 Nm
Axpert King 3KW/5KW Inverter/Charger User Manual (Version 1.0) — manual pp.5-8, battery/AC/PV wiring tables
|
| weight_kg |
13.5
Axpert King Off-Grid Inverter — brochure / datasheet — brochure 'Net Weight (kgs) 13.5'
|
| width_mm |
303
Axpert King Off-Grid Inverter — brochure / datasheet — brochure 'Dimension, D x W x H (mm) 140 x 303 x 525'
|
| wire_gauges | Battery (5KW, 200 A typical, 200 Ah): 1 x 1/0 AWG or 2 x 4 AWG with 60 mm or 44 mm ring terminal; AC (5KW): 8 AWG; PV: 6 AWG |
Installation
| clearance_bottom_mm | — |
| clearance_left_mm | — |
| clearance_right_mm | — |
| clearance_top_mm | — |
| indoor_outdoor | — |
| installation_humidity_range | — |
| installation_temperature_range_c | 0 to 55 ambient |
| max_installation_altitude_m | — |
| mounting_orientation | vertical — 'The recommended installation position is to be adhered to the wall vertically' |
| orientation_allowed | ['vertical'] |
| orientation_forbidden | — |
| surface_requirements | solid surface; install at eye level so the LCD can be read |
| two_person_lift_required | — |
| ventilation_requirements | — |
Environment
| cooling_method | — |
| fan_replaceable | — |
| ip_rating | — |
| max_altitude_m | — |
| noise_level_db | — |
| operating_temperature_c | 0 to 55 |
| pollution_degree | — |
| relative_humidity | 5% to 95% Relative Humidity (Non-condensing) |
| storage_temperature_c |
-15 to 60
Axpert King 3KW/5KW Inverter/Charger User Manual (Version 1.0) — manual General specification table (Table 5), pp.32-35
|
Interfaces & connectors
| ac_terminal_type | screw terminal, 8 AWG (5KW), 1.4-1.6 Nm |
| battery_terminal_type | ring-terminal bolted connection (60 mm or 44 mm ring terminal), 2-3 Nm |
| bluetooth | yes — manual: Bluetooth range '6~7m in an open space' |
| can | UNKNOWN — CAN is not listed in the brochure's communication-interface row; the existing record's communication_can=true is not confirmed by either fetched document |
| dry_contacts |
yes — dry contact rated 3A/250VAC
Axpert King 3KW/5KW Inverter/Charger User Manual (Version 1.0) — manual p.10, dry contact rated 3A/250VAC
|
| ethernet | — |
| parallel_interface | yes — 'Parallel-able YES'; the manual refers to a separate parallel installation guide and does not state a maximum unit count |
| protocol_notes | Brochure communication-interface row lists USB/RS232/RS485/Bluetooth/Dry-contact. The manual's connection chapter (p.10) documents only the RS232 and Bluetooth connections. |
| pv_connector_type | screw terminal, 6 AWG cable, 1.2-1.6 Nm |
| rs232 | yes |
| rs485 | yes (brochure) |
| usb | yes (brochure 'Communication Interface USB/RS232/RS485/Bluetooth/Dry-contact') |
| wifi | — |
Controls & display
| audible_alarm | yes — warning codes are signalled with defined beep patterns |
| buttons | — |
| display_type | LCD |
| leds | green LED (output / charging status), red LED (fault) |
| local_display | True |
| mobile_app | — |
| remote_display_option | — |
| status_indicators | battery capacity display in 0-24% / 25-49% / 50-74% / 75-100% steps |
| touchscreen | False |
| web_interface | — |
Protection
| anti_islanding | — |
| fault_code_range | fault codes 01-59 documented in the manual (pp.29-30) |
| over_current | yes — overload warning/fault codes documented |
| over_temperature | yes — overtemperature warning/fault codes documented |
| over_voltage | — |
| overcharge_protection_voltage_v |
66
Axpert King Off-Grid Inverter — brochure / datasheet
|
| reverse_polarity | — |
| short_circuit | — |
| under_voltage | yes — low-battery warning documented |
Certifications
| emc | [] |
| grid_codes | [] |
| other | [] |
| regional |
['CE']
Axpert King 3KW/5KW Inverter/Charger User Manual (Version 1.0) — manual p.35, safety certification 'CE'
|
| safety | [] |
Warranty & service
| conditions | — |
| extended_options_years | — |
| standard_years | — |
Packaging & logistics
| gross_weight_kg | — |
| package_depth_mm | — |
| package_height_mm | — |
| package_width_mm | — |
Документи
Задокументована сумісність
Лише задокументовані пари. Якщо продукту тут немає, це означає, що не отримано документа, який називає цю пару, а не те, що вона несумісна.
inverter_battery
Deye AI-W5.1-B
COMPATIBLEmanufacturer-documented
Deye Approved Battery List DY-LV48-0109
Pytes V5 / V5-alpha (printed as V5° / V5°α)
COMPATIBLEofficially-verified
Pytes Inverter Compatibility List V.20230819, https://www.pytesess.com/ueditor/php/upload/file/20240705/1720170604646137.pdf (fetched 2026-09-01)
Pytes E-Box 48100R
COMPATIBLEofficially-verified
Pytes Inverter Compatibility List V.20230819, https://www.pytesess.com/ueditor/php/upload/file/20240705/1720170604646137.pdf (fetched 2026-09-01)
Dyness A48100
COMPATIBLEofficially-verified
Dyness 'Approved Compatibility List of Inverter Brands' (low voltage battery), https://basic-solar.de/wp-content/uploads/2025/01/kompatibilitaetsliste_dyness.pdf (fetched 2026-09-01)
BSLBATT B-LFP48-200E (19-inch rack battery, 10.24 kWh)
COMPATIBLEmanufacturer-documented
BSLBATT B-LFP48 Rack Battery Pack User Manual V2.7 CAN/RS485 protocol tables, https://bslbatt.com/wp-content/uploads/2024/09/B-LFP48-User-Manual-V2.7-Rack-Battery-Pack.pdf (fetched 2026-09-01)
BSLBATT B-LFP48-100E (3U Server Rack Battery)
COMPATIBLEmanufacturer-documented
BSLBATT B-LFP48 Rack Battery Pack User Manual V2.7 CAN/RS485 protocol tables, https://bslbatt.com/wp-content/uploads/2024/09/B-LFP48-User-Manual-V2.7-Rack-Battery-Pack.pdf (fetched 2026-09-01)
inverter_evse
go-e GmbH go-eCharger Gemini (11kW and 22kW variants)
COMPATIBLEinferred-from-electrical-parameters
go-e Gemini Datasheet (open local API/Modbus TCP/MQTT) + third-party EMS tools (evcc, openWB)
Зафіксовані конфлікти
communication interfaces (communication_can / interfaces) Review required
USB / RS232 / RS485 / Bluetooth / Dry-contact — Axpert King brochure, 'Communication Interface' row
RS232 and Bluetooth only — Axpert King 3KW/5KW user manual p.10, connection chapter
The brochure lists the full port complement of the platform while the manual documents only the connections it gives wiring instructions for. Neither fetched document lists CAN, so the existing record's communication_can=true is unsupported by these two sources.
battery_voltage_max_v Review required
48 — Existing record / Axpert King brochure spec row 'Battery Voltage 48 VDC' (nominal)
66 — Axpert King 3KW/5KW user manual, Battery Mode table: 'operating range 40Vdc -66Vdc'
The existing 48 V value is the NOMINAL battery voltage from the brochure; the manual's 40-66 Vdc is the DC input operating window. The record's battery_voltage_min_v/max_v fields should hold the operating window, not the nominal value.
communication interfaces (communication_can / interfaces) Review required
USB / RS232 / RS485 / Bluetooth / Dry-contact — Axpert King brochure, 'Communication Interface' row
RS232 and Bluetooth only — Axpert King 3KW/5KW user manual p.10, connection chapter
The brochure lists the full port complement of the platform while the manual documents only the connections it gives wiring instructions for. Neither fetched document lists CAN, so the existing record's communication_can=true is unsupported by these two sources.
battery_voltage_max_v Review required
48 — Existing record / Axpert King brochure spec row 'Battery Voltage 48 VDC' (nominal)
66 — Axpert King 3KW/5KW user manual, Battery Mode table: 'operating range 40Vdc -66Vdc'
The existing 48 V value is the NOMINAL battery voltage from the brochure; the manual's 40-66 Vdc is the DC input operating window. The record's battery_voltage_min_v/max_v fields should hold the operating window, not the nominal value.
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| AC Voltage Regulation (battery mode) | 230 VAC ± 5% |
| Battery cable / ring terminal (5KW, 200A, 200AH) | 1*1/0AWG or 2*4AWG, ring terminal 60 mm or 44 mm, torque 2~3 Nm |
| Battery mode DC input operating range | 40Vdc - 66Vdc (nominal 48Vdc) |
| Bluetooth range | 6~7m in an open space |
| Bulk voltage (AGM) | 56.4 Vdc |
| Dry contact rating | 3A/250VAC |
| Efficiency (Peak) | 93 % at Line Mode, 90% at Battery Mode |
| Floating Charge Voltage | 54 VDC |
| Input Voltage Range | 110-280 VAC |
| Maximum AC Charge Current | 60 A |
| Maximum Solar Charge Current | 80 A |
| Surge Power | 10000VA for 5 sec |
| Transfer Time | 0 ms |
| identity.product_status | UNKNOWN — as of 2026-09-02 the Axpert King 3KVA/5KVA product-detail page (https://voltronicpower.com/en-US/Product/Detail/Axpert-King-3KVA-5KVA) redirects to the Voltronic Power homepage and the model no longer appears in the site's Off-Grid Inverter menu (which now lists Axpert King IP52 and Axpert King II TWIN). The brochure and manual PDFs are still served. Treated as evidence of withdrawal, not as a documented status. |
| model column headings | 'Axpert King 3K' and 'Axpert King 5K' |
| withheld:product_status | "discontinued" |