APsystems EZ1-M
Official manufacturer EU перевірено 22 вересня 2026 р.
Identity
| category | microinverters |
| ean | — |
| firmware | {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'} |
| generation | — |
| manufacturer | APsystems |
| market_version | EMEA (EN 50549 / VDE-AR-N 4105 / G98/G99 / CEI 0-21) |
| model | EZ1-M |
| mpn | — |
| product_family | EZ1 |
| product_status | active |
| region | EU |
| release_year | — |
| series | EZ1 Microinverter Series (plug-in / balcony, DIY) |
| sku | — |
Electrical
| ac_connection | — |
| ac_voltage_range | 184V-253V |
| battery_capacity_range_kwh | — |
| battery_communication | — |
| battery_max_charge_current_a | — |
| battery_max_charge_power_w | — |
| battery_max_discharge_current_a | — |
| battery_max_discharge_power_w | — |
| battery_nominal_battery_voltage_v | — |
| battery_type | N/A - not a battery-capable product |
| battery_voltage_range_v | — |
| eps_peak_power | — |
| eps_phase | — |
| eps_rated_power_va | — |
| eps_switchover_time_ms | — |
| eps_voltage | — |
| european_efficiency_pct | — |
| external_transfer_switch_required | — |
| frequency_range_hz | 48Hz-51Hz |
| inrush_current | — |
| max_ac_active_power_w | — |
| max_ac_current_a | 2.6 / 3.5 |
| max_apparent_power_va | 600 / 799 |
| max_backfeed_current_a | — |
| max_dc_input_power_w | — |
| max_dc_voltage_v | 60 |
| max_efficiency_pct | 96.7 |
| max_input_current_per_mppt_a | 20 |
| max_output_fault_current_a | — |
| max_short_circuit_current_per_mppt_a | 25 |
| mppt_efficiency_pct | 99.5 |
| mppt_voltage_range_v | 26V-60V |
| night_self_consumption_w | 20 mW |
| nominal_ac_voltage | 230 V |
| nominal_dc_voltage_v | — |
| nominal_frequency_hz | 50 |
| number_of_mppt | 2 |
| parallel_capability | — |
| phase_count | 1 |
| power_factor_range | 0.99 (default) |
| rated_ac_power_w | — |
| rated_mppt_voltage_range_v | 28V-45V |
| startup_voltage_v | — |
| strings_per_mppt | 1 |
| thd_pct | — |
Physical / mechanical
| ac_terminal | — |
| cooling | Natural Convection - No Fans |
| dc_connector | MC4 Compatible |
| depth_mm | 36.5 |
| dimensions_mm | 263 x 218 x 36.5 |
| display | — |
| enclosure_material | — |
| height_mm | 218 |
| mounting | — |
| noise_db | — |
| weight_kg | 2.8 |
| width_mm | 263 |
Installation
| cable_requirements | — |
| commissioning | — |
| installation_angle | — |
| mounting_clearances | — |
| torque | — |
Environment
| ingress_protection | IP67 |
| max_altitude_m | — |
| operating_temperature_c | -40 to +65 |
| pollution_degree | — |
| protective_class | — |
| relative_humidity_pct | — |
| storage_temperature_c | — |
Interfaces & connectors
| app | AP EasyPower APP |
| communication | ['Wi-Fi', 'Bluetooth'] |
| dry_contact | — |
| meter_interface | — |
| monitoring_portal | — |
| protocols | [] |
Protection
| anti_islanding | — |
| arc_fault | — |
| dc_switch | — |
| insulation_monitoring | — |
| overvoltage_category | — |
| rcmu | — |
| reverse_polarity | — |
| surge_protection_ac | — |
| surge_protection_dc | — |
Certifications
| standards | ['EN/IEC 62109-1', 'EN/IEC 62109-2', 'EN 61000 series', 'EN 55011', 'EN 62920', 'EN 50549', 'VDE-AR-N 4105', 'G98/G99', 'CEI 0-21'] |
Warranty & service
| conditions | — |
| extension_options | — |
| standard_years | 12 |
Документи
user-manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
APsystems EZ1 series Microinverters (For EMEA) - User manual — знайдено, не отримано
rev Rev1.1
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| Datasheet footnotes (1)-(6) | (1) The factory setting could be 600VA as default. (2) If the microinverter is connected to grid by plug, please comply with the local regulation about the power limit. (3) For some countries it is limited to 1 because of the regulations. (4) The EasyPower App supports monitoring up to 4 units of product from the EZ1 series... In Germany, the maximum power for plug-in PV systems is 800W, otherwise a professional electrician or installer is needed. (5) Support and warranty is not availabe for rooftop installation systems. (6) APsystems' Microinverter Systems fully meet the rapid shutdown requirement without the need to install additional electrical equipment. |
| Input Data (DC), row 'Operating Voltage Range' (column EZ1-M) | 26V-60V |
| Input Data (DC), row 'Recommended PV Module Power (STC) Range' (column EZ1-M) | 300Wp-730Wp+ |
| Isolation | High Frequency Transformers, Galvanically Isolated |
| Max Connected Units | 2 |
| Max Continuous Output Power | 600VA(1)/799VA |
| Mechanical Data (column EZ1-M) | Storage -40C to +85C; DC Connector MC4 Compatible; Communication built-in Wi-Fi and Bluetooth; Peak efficiency 96.7% |
| Recommended PV Module Power (STC) | 300Wp-730Wp+ |
| battery.communication | UNKNOWN |
| battery.max_charge_current_a | UNKNOWN |
| battery.max_charge_power_w | UNKNOWN |
| battery.max_discharge_current_a | UNKNOWN |
| battery.max_discharge_power_w | UNKNOWN |
| battery.nominal_battery_voltage_v | UNKNOWN |