Chilicon Power CP-250E
Official manufacturer NA перевірено 23 вересня 2026 р.
Identity
| category | microinverters |
| manufacturer | Chilicon Power |
| model | CP-250E |
| region | — |
Electrical
| ac_voltage_range_v |
[[183, 229], [211, 264]]
CP-250E Data Sheet, REV250 11.24.20
|
| branch_circuit_rating_a |
30
CP-250E Data Sheet, REV250 11.24.20
|
| cec_weighted_efficiency_percent |
96.0
CP-250E Data Sheet, REV250 11.24.20
|
| communication_method |
Mesh Networked Power Line (130.2 kHz carrier)
CP-250E Data Sheet, REV250 11.24.20
|
| gateway_required |
True
CP-250E Data Sheet, REV250 11.24.20
|
| grid_frequency_hz |
60
CP-250E Data Sheet, REV250 11.24.20
|
| grid_frequency_range_hz |
[59.3, 60.5]
CP-250E Data Sheet, REV250 11.24.20
|
| max_ac_current_a |
[1.33, 1.2]
CP-250E Data Sheet, REV250 11.24.20
|
| max_dc_voltage_v |
60
CP-250E Data Sheet, REV250 11.24.20
|
| max_input_current_per_input_a |
13.5
CP-250E Data Sheet, REV250 11.24.20
|
| max_short_circuit_current_per_input_a |
16
CP-250E Data Sheet, REV250 11.24.20
|
| maximum_units_per_branch |
[18, 20]
CP-250E Data Sheet, REV250 11.24.20
|
| mppt_voltage_max_v |
41
CP-250E Data Sheet, REV250 11.24.20
|
| mppt_voltage_min_v |
26
CP-250E Data Sheet, REV250 11.24.20
|
| night_time_consumption_mw |
[40, 80]
CP-250E Data Sheet, REV250 11.24.20
|
| nominal_ac_voltage_v |
[208, 240]
CP-250E Data Sheet, REV250 11.24.20
|
| operating_voltage_max_v |
51
CP-250E Data Sheet, REV250 11.24.20
|
| operating_voltage_min_v |
24
CP-250E Data Sheet, REV250 11.24.20
|
| peak_efficiency_percent |
96.6
CP-250E Data Sheet, REV250 11.24.20
|
| power_factor_range |
[-0.6, 0.6]
CP-250E Data Sheet, REV250 11.24.20
|
| rated_ac_power_w |
[277, 289]
CP-250E Data Sheet, REV250 11.24.20
|
| recommended_module_power_max_w |
420
CP-250E Data Sheet, REV250 11.24.20
|
| recommended_module_power_min_w |
190
CP-250E Data Sheet, REV250 11.24.20
|
| startup_voltage_max_v |
51
CP-250E Data Sheet, REV250 11.24.20
|
| startup_voltage_min_v |
26
CP-250E Data Sheet, REV250 11.24.20
|
| static_mppt_efficiency_percent_max |
99.8
CP-250E Data Sheet, REV250 11.24.20
|
| static_mppt_efficiency_percent_min |
99.5
CP-250E Data Sheet, REV250 11.24.20
|
| warranty_product_years |
25
CP-250E Data Sheet, REV250 11.24.20
|
Physical / mechanical
| weight_kg |
1.55
CP-250E Data Sheet, REV250 11.24.20
|
Environment
| enclosure_rating |
NEMA 6
CP-250E Data Sheet, REV250 11.24.20
|
| operating_temperature_max_c |
65
CP-250E Data Sheet, REV250 11.24.20
|
| operating_temperature_min_c |
-40
CP-250E Data Sheet, REV250 11.24.20
|
Interfaces & connectors
| documented_ports | [{'port_role': 'DC_IN', 'port_label_from_manual': 'MC4', 'port_type': 'MC4', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'document': 0, 'page': 'Title line / Compatibility', 'quote': 'CP-250E-60-72-208/240-MC4 Microinverter ... Compatibility | 60 or 72 Cell Mono or Poly PV modules'}, {'port_role': 'AC_OUT', 'port_label_from_manual': 'MTC (modular trunk cable) branch connection', 'port_type': 'Branch cable', 'direction': 'output', 'electrical_domain': 'AC', 'document': 0, 'page': 'OUTPUT DATA (AC)', 'quote': 'Maximum units per branch circuit | 18 (30A 10 AWG) | 20 (30A 10 AWG)'}] |
Документи
datasheet
CP-250E Data Sheet, REV250 11.24.20
product_page
Chilicon Power Support Materials
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | North American product: 60 Hz, 208 V and 240 V service, UL1741 / UL1741SA / IEEE 1547 / CSA C22.2 No. 107.1 / CA Rule 21 / HECO Rule 14H and 22 / NEC 690.12(B)(2). The datasheet title reads 'CP-250E-60-72-208/240-MC4 Microinverter'; that string embeds cell-count and service-voltage options, so the designation Chilicon uses throughout its catalogue, CP-250E, is the model. Two AC columns ('@ 208 V' |