⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Microinverters

Chilicon Power CP-250E

Побудувати систему з цим продуктом

Official manufacturer NA перевірено 23 вересня 2026 р.

Identity

category microinverters
manufacturer Chilicon Power
model CP-250E
region —

Electrical

ac_voltage_range_v [[183, 229], [211, 264]]
CP-250E Data Sheet, REV250 11.24.20
branch_circuit_rating_a 30
CP-250E Data Sheet, REV250 11.24.20
cec_weighted_efficiency_percent 96.0
CP-250E Data Sheet, REV250 11.24.20
communication_method Mesh Networked Power Line (130.2 kHz carrier)
CP-250E Data Sheet, REV250 11.24.20
gateway_required True
CP-250E Data Sheet, REV250 11.24.20
grid_frequency_hz 60
CP-250E Data Sheet, REV250 11.24.20
grid_frequency_range_hz [59.3, 60.5]
CP-250E Data Sheet, REV250 11.24.20
max_ac_current_a [1.33, 1.2]
CP-250E Data Sheet, REV250 11.24.20
max_dc_voltage_v 60
CP-250E Data Sheet, REV250 11.24.20
max_input_current_per_input_a 13.5
CP-250E Data Sheet, REV250 11.24.20
max_short_circuit_current_per_input_a 16
CP-250E Data Sheet, REV250 11.24.20
maximum_units_per_branch [18, 20]
CP-250E Data Sheet, REV250 11.24.20
mppt_voltage_max_v 41
CP-250E Data Sheet, REV250 11.24.20
mppt_voltage_min_v 26
CP-250E Data Sheet, REV250 11.24.20
night_time_consumption_mw [40, 80]
CP-250E Data Sheet, REV250 11.24.20
nominal_ac_voltage_v [208, 240]
CP-250E Data Sheet, REV250 11.24.20
operating_voltage_max_v 51
CP-250E Data Sheet, REV250 11.24.20
operating_voltage_min_v 24
CP-250E Data Sheet, REV250 11.24.20
peak_efficiency_percent 96.6
CP-250E Data Sheet, REV250 11.24.20
power_factor_range [-0.6, 0.6]
CP-250E Data Sheet, REV250 11.24.20
rated_ac_power_w [277, 289]
CP-250E Data Sheet, REV250 11.24.20
recommended_module_power_max_w 420
CP-250E Data Sheet, REV250 11.24.20
recommended_module_power_min_w 190
CP-250E Data Sheet, REV250 11.24.20
startup_voltage_max_v 51
CP-250E Data Sheet, REV250 11.24.20
startup_voltage_min_v 26
CP-250E Data Sheet, REV250 11.24.20
static_mppt_efficiency_percent_max 99.8
CP-250E Data Sheet, REV250 11.24.20
static_mppt_efficiency_percent_min 99.5
CP-250E Data Sheet, REV250 11.24.20
warranty_product_years 25
CP-250E Data Sheet, REV250 11.24.20

Physical / mechanical

weight_kg 1.55
CP-250E Data Sheet, REV250 11.24.20

Environment

enclosure_rating NEMA 6
CP-250E Data Sheet, REV250 11.24.20
operating_temperature_max_c 65
CP-250E Data Sheet, REV250 11.24.20
operating_temperature_min_c -40
CP-250E Data Sheet, REV250 11.24.20

Interfaces & connectors

documented_ports [{'port_role': 'DC_IN', 'port_label_from_manual': 'MC4', 'port_type': 'MC4', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'document': 0, 'page': 'Title line / Compatibility', 'quote': 'CP-250E-60-72-208/240-MC4 Microinverter ... Compatibility | 60 or 72 Cell Mono or Poly PV modules'}, {'port_role': 'AC_OUT', 'port_label_from_manual': 'MTC (modular trunk cable) branch connection', 'port_type': 'Branch cable', 'direction': 'output', 'electrical_domain': 'AC', 'document': 0, 'page': 'OUTPUT DATA (AC)', 'quote': 'Maximum units per branch circuit | 18 (30A 10 AWG) | 20 (30A 10 AWG)'}]

Документи

datasheet CP-250E Data Sheet, REV250 11.24.20
manual CP-250E-60-72-208-240-MC4 User Manual Rev 11/19/22
product_page Chilicon Power Support Materials

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesNorth American product: 60 Hz, 208 V and 240 V service, UL1741 / UL1741SA / IEEE 1547 / CSA C22.2 No. 107.1 / CA Rule 21 / HECO Rule 14H and 22 / NEC 690.12(B)(2). The datasheet title reads 'CP-250E-60-72-208/240-MC4 Microinverter'; that string embeds cell-count and service-voltage options, so the designation Chilicon uses throughout its catalogue, CP-250E, is the model. Two AC columns ('@ 208 V'