⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Microinverters

Enphase IQ8+

Побудувати систему з цим продуктом

Official manufacturer NA перевірено 20 вересня 2026 р.

Identity

category microinverters
generation IQ8
manufacturer Enphase
market_version US/Canada, 240 V split-phase (L-L, 180 deg)
model IQ8+
product_family IQ8 Series Microinverters
product_status active
region —
sku —

Electrical

ac_coupling_compatibility —
ac_rated_power_w 290
grid_profiles ['CA Rule 21 (UL 1741-SA)', 'IEEE 1547:2018 (UL 1741-SB 3rd Ed.)']
max_dc_input_power_w ~720 (derived from 12A x 60V, not an explicitly stated single figure)
max_dc_voltage_v 60
max_input_current_a 12
max_short_circuit_current_a 25
monitoring_protocol Power line communication (PLC) to Enphase Envoy
mppt_range_v 27-45
num_mppt —
supported_module_power_range_w 235-440

Physical / mechanical

depth_mm 30.2
enclosure_material Class II double-insulated, corrosion-resistant polymeric enclosure
height_mm 212
mounting_bolt_size 6 mm (1/4 in) or 8 mm (5/16 in) racking hardware
mounting_type ['rooftop']
torque_specs 6 mm (1/4 in): 5 N.m (45-50 in-lb); 8 mm (5/16 in): 9 N.m (80-85 in-lb) - IQ8 series installation manual p.17
Installation and Operation Manual - Enphase IQ8, IQ8+, IQ8M, IQ8A and IQ8H Microinverters — installation manual p.17
weight_kg 1.1
DATA SHEET - IQ8 Series Microinverters (IQ8, IQ8+, IQ8M, IQ8A, IQ8HC) — MECHANICAL DATA, '1.1 kg (2.3 lb)'
width_mm 175
DATA SHEET - IQ8 Series Microinverters (IQ8, IQ8+, IQ8M, IQ8A, IQ8HC) — MECHANICAL DATA, 'Dimensions (H x W x D) 212 mm x 175 mm x 30.2 mm'

Installation

clearance_bottom_mm 19
Installation and Operation Manual - Enphase IQ8, IQ8+, IQ8M, IQ8A and IQ8H Microinverters — installation manual p.17
clearance_top_mm 13
direct_sunlight_restriction Always place the microinverter under the PV module, protected from direct exposure to rain, sun and other harmful weather events (manual p.17)
indoor_outdoor outdoor, wet-location approved (NEMA 250 type 6)
installation_notes Vertical mount requires >30 cm (12 in) clearance from the edges of the PV module (manual p.17).
mounting_orientation horizontal (bracket side up) or vertical, mounted under the PV module
orientation_allowed ['horizontal (bracket side up)', 'vertical']
orientation_forbidden ['upside down']

Environment

cooling_method natural convection - no fans
ip_rating —
nema_rating NEMA 250, type 6
operating_temperature_c -40 to +60
storage_temperature_c —

Interfaces & connectors

ac_terminal_type Enphase IQ Connector on IQ Cable (12 AWG double-insulated outdoor trunk cable)
can False
cloud_api Enphase Enlighten (via IQ Gateway)
ethernet False
powerline_communication proprietary PLC to IQ Gateway (Envoy)
protocol_notes No IP/Modbus/serial interface on the microinverter itself.
pv_connector_type Enphase IQ DC connector; MC4 via Q-DCC-2 adapter cable
rs485 False
wifi False

Controls & display

display_type —
leds flashing green = normal operation + IQ Gateway communication; flashing orange = grid normal but no gateway communication; flashing red = AC grid absent or out of specification; solid red = DC Resistance Low, Power Off (manual p.26)
Installation and Operation Manual - Enphase IQ8, IQ8+, IQ8M, IQ8A and IQ8H Microinverters — installation manual p.26
local_display False

Protection

anti_islanding yes (IEEE 1547:2018 / UL 1741-SB 3rd Ed. listing)
ground_fault_protection DC Resistance Low detection (solid red LED)
overvoltage_category Overvoltage class DC port: II
protection_class Class II double-insulated

Certifications

emc ['FCC Part 15 Class B', 'ICES-0003 Class B']
grid_codes ['CA Rule 21 (UL 1741-SA)', 'IEEE 1547:2018 (UL 1741-SB 3rd Ed.)']
DATA SHEET - IQ8 Series Microinverters (IQ8, IQ8+, IQ8M, IQ8A, IQ8HC) — Compliance row of the IQ8 series datasheet
other []
regional []
safety ['UL 62109-1', 'CAN/CSA-C22.2 NO. 107.1-01']

Warranty & service

design_life_years —
standard_years up to 25 (limited warranty per datasheet wording)

Документи

datasheet DATA SHEET - IQ8 Series Microinverters (IQ8, IQ8+, IQ8M, IQ8A, IQ8HC) rev DSH-00412-5.0-EN-2025-10-10
datasheet Enphase IQ8 Series Microinverters Data Sheet (North America) rev DSH-00378-3.0-EN-2025-08-25
installation-manual Installation and Operation Manual - Enphase IQ8, IQ8+, IQ8M, IQ8A and IQ8H Microinverters
product-page Enphase Microinverters (installer product page)

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

AC short circuit fault current over 3 cycles2 Arms
CEC weighted efficiency97 %
CEC weighted efficiency - column IQ8PLUS-72-2-US97% (IQ8+) / 97.5% (IQ8M) as printed in each column
Commonly used module pairings (W) - column IQ8PLUS-72-2-US235-440
Corroboration only (NOT the asserted source)Enphase IQ8 Series International sheet: 'Number of input DC connectors (pairs) per single MPP tracker: 1'; Enphase IQ8 Commercial sheet: 'PV array configuration: 1 x 1 ungrounded array'
DC port backfeed current0 mA
Extended frequency range47-68 Hz
Max continuous output current1.21 A
Max units per 20A branch circuit13
Max. input DC short-circuit current - column IQ8PLUS-72-2-US25 A
Min/Max start voltage22/58 V
Module compatibility - column IQ8PLUS-72-2-USTo meet compatibility, PV modules must be within the maximum input DC voltage and maximum module Isc
Nominal voltage/range240, split-phase (L-L), 180 deg
Operating range16-58 V
PV array configurationUngrounded array; no additional DC side protection required
Peak output power300 VA
withheld:ac.ac_voltage_range"UNKNOWN - no AC voltage-range row on this sheet"
withheld:ac.nominal_ac_current_a"UNKNOWN - not printed"
withheld:ac.thd_pct"UNKNOWN - not printed"
withheld:dc.max_dc_input_power_w"UNKNOWN - not printed on this sheet"
withheld:dc.max_start_voltage_v58
withheld:safety.isolation_topology"UNKNOWN - not printed on this sheet"
withheld:safety.max_altitude_m"UNKNOWN - not printed"
withheld:topology.ac_output_connector"UNKNOWN - not printed on this sheet"
withheld:topology.mppt_independence"independent - the unit's single MPPT owns its single PV input; one module per microinverter"