SolaX Power X1-Micro 2000 G2
Official manufacturer GLOBAL перевірено 22 вересня 2026 р.
Identity
| category | microinverters |
| ean | — |
| firmware | {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'} |
| generation | G2 |
| manufacturer | SolaX Power |
| market_version | — |
| model | X1-Micro 2000 G2 |
| mpn | — |
| product_family | X1-Micro |
| product_status | — |
| product_type | Four-in-one grid-tied microinverter |
| region | GLOBAL |
| release_year | — |
| series | X1-Micro 4 in 1 G2 |
| sku | — |
Electrical
| ac_connection | Single phase |
| ac_voltage_range | 180 V to 276 V |
| battery_capacity_range_kwh | — |
| battery_communication | — |
| battery_max_charge_current_a | — |
| battery_max_charge_power_w | — |
| battery_max_discharge_current_a | — |
| battery_max_discharge_power_w | — |
| battery_nominal_battery_voltage_v | — |
| battery_type | — |
| battery_voltage_range_v | — |
| eps_peak_power | — |
| eps_phase | — |
| eps_rated_power_va | — |
| eps_switchover_time_ms | — |
| eps_voltage | — |
| european_efficiency_pct | — |
| external_transfer_switch_required | — |
| frequency_range_hz | 50 +/- 5 Hz; 60 +/- 5 Hz |
| inrush_current | — |
| max_ac_active_power_w | — |
| max_ac_current_a | 8.7 |
| max_apparent_power_va | 2000 |
| max_backfeed_current_a | — |
| max_dc_input_power_w | — |
| max_dc_voltage_v | 60 |
| max_efficiency_pct | 97.0 |
| max_input_current_per_mppt_a | 18 |
| max_output_fault_current_a | — |
| max_short_circuit_current_per_mppt_a | 25 |
| mppt_efficiency_pct | 99.9 |
| mppt_voltage_range_v | 22 V to 60 V |
| night_self_consumption_w | — |
| nominal_ac_voltage | 220 / 230 / 240 V |
| nominal_dc_voltage_v | — |
| nominal_frequency_hz | 50 |
| number_of_mppt | 4 |
| official_manual_url |
https://www.solaxpower.com/uploads/file/solax-x1-micro-4-in-1-g2-user-manual-en.pdf
SolaX X1-Micro 4 in 1 G2 User Manual v0.1 (2025-07-11)
|
| parallel_capability | — |
| phase_count | 1 |
| power_factor_range | 0.8 leading to 0.8 lagging |
| rated_ac_power_w | — |
| rated_mppt_voltage_range_v | — |
| startup_voltage_v | 20 |
| strings_per_mppt | 1 |
| thd_pct | 3 |
Physical / mechanical
| ac_terminal | — |
| cooling | Natural cooling |
| dc_connector | — |
| depth_mm | 41 |
| dimensions_mm | 317 x 225 x 41 |
| display | — |
| enclosure_material | — |
| height_mm | 225 |
| mounting | — |
| noise_db | — |
| weight_kg | 5.2 |
| width_mm | 317 |
Installation
| cable_requirements | — |
| commissioning | — |
| installation_angle | — |
| mounting_clearances | — |
| torque | — |
Environment
| ingress_protection | IP67 |
| max_altitude_m | — |
| operating_temperature_c | -40 to +65 |
| pollution_degree | — |
| protective_class | — |
| relative_humidity_pct | 0 to 100 |
| storage_temperature_c | — |
Interfaces & connectors
| app | — |
| communication | ['WiFi (built-in)'] |
| dry_contact | — |
| meter_interface | — |
| monitoring_portal | SolaXCloud |
| protocols | — |
Protection
| anti_islanding | Safety protection relay integrated |
| arc_fault | — |
| dc_switch | — |
| insulation_monitoring | — |
| overvoltage_category | — |
| rcmu | — |
| reverse_polarity | — |
| surge_protection_ac | — |
| surge_protection_dc | — |
Certifications
| standards | ['IEC 61727', 'IEC 62116', 'EN 50549', 'VDE-AR-N 4105'] |
Warranty & service
| conditions | — |
| extension_options | — |
| standard_years | — |
Документи
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| AC OUTPUT, row 'Max. units per 12AWG branch*' (column X1-Micro-2000-G2) | 2@220 V / 2@230 V / 2@240 V |
| Commonly used module power per input | 400~670+ W |
| EFFICIENCY (column X1-Micro-2000-G2) | Max. efficiency 97.00%; MPPT efficiency 99.90%; Power consumption (night) < 40 mW |
| GENERAL (column X1-Micro-2000-G2) | Dimensions 317 × 225 × 41 mm; Weight 5.2 kg |
| Max. AC output current | 9.10 A at 220 V / 8.70 A at 230 V / 8.34 A at 240 V |
| Max. PV input current | read 1: 4 x 18 A | 4 x 20 A | 4 x 25 A | 4 x 18 A (1875 / 2000 / 2250 / 2400 G2); read 2: 4 x 17 A | 4 x 20 A | 4 x 18 A | 4 x 25 A |
| Max. commonly used module power | 360~600+ W / 400~670+ W / 450~700+ W / 500~750+ W |
| Max. input short circuit current | read 1: 4 x 20 A | 4 x 25 A | 4 x 25 A | 4 x 20 A; read 2: 4 x 20 A | 4 x 25 A | 4 x 25 A | 4 x 25 A |
| Max. units per branch (10 AWG / 12 AWG at 220 V) | 3 |
| Night power consumption | < 40 mW |
| Nominal frequency | 50 Hz / 60 Hz |
| PV INPUT, row 'Commonly used module power per input' (column X1-Micro-2000-G2) | 400 ~ 670+ W |
| Rated AC output power | 1875 VA / 2000 VA / 2250 VA / 2400 VA |
| Rated AC output power / max. continuous output power | 2000 VA / 2000 VA |
| THDi | < 3 % (at rated power) |
| battery.communication | UNKNOWN |
| battery.max_charge_current_a | UNKNOWN |
| battery.max_charge_power_w | UNKNOWN |
| battery.max_discharge_current_a | UNKNOWN |
| battery.max_discharge_power_w | UNKNOWN |
| battery.nominal_battery_voltage_v | UNKNOWN |
| identity.region_as_printed | EU/global |