База знань › Power Conversion Systems
KACO new energy blueplanet gridsave 92.0 TL3-S
Manufacturer documented GLOBAL перевірено 23 вересня 2026 р.
Identity
| category | power_conversion_systems |
| manufacturer | KACO new energy |
| model | blueplanet gridsave 92.0 TL3-S |
| region | GLOBAL |
Electrical
| ac_voltage_range |
300 - 580 V
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| ac_voltage_v |
400
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| bidirectional |
True
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| dc_voltage_max_v |
1315
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| dc_voltage_min_v |
668
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| grid_frequency_hz |
[50, 60]
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| max_ac_power_kva |
92
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| max_dc_current_a |
145
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| max_efficiency_charge_percent |
98.5
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| max_efficiency_percent |
98.7
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| max_parallel_units |
2
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| number_of_dc_inputs |
1
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| parallel_supported |
True
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| phase_count |
3
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| rated_ac_current_a |
132.3
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| rated_ac_power_kw |
92
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| reactive_power_support |
True
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| thd_percent |
<3
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
Physical / mechanical
| weight_kg |
80
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
Environment
| ip_rating |
IP66 / NEMA 4X
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| operating_temperature_max_c |
60
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| operating_temperature_min_c |
-20
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
Interfaces & connectors
| communications |
['Ethernet', 'USB']
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
| documented_ports | [{'port_role': 'ETHERNET', 'port_label_from_manual': 'Ethernet', 'port_type': 'Ethernet', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Interfaces', 'quote': 'Ethernet, USB'}, {'port_role': 'USB', 'port_label_from_manual': 'USB', 'port_type': 'USB', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Interfaces', 'quote': 'Ethernet, USB'}, {'port_role': 'BATTERY_DC', 'port_label_from_manual': 'DC inputs', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'quantity': 1, 'document': 1, 'page': 'DC input', 'quote': 'Number of DC inputs 1'}] |
| protocols |
['TCP/IP', 'Modbus TCP based on SunSpec']
blueplanet gridsave 92.0 - 137 TL3-S technical data (KACO doc EN 500xxxx-01-220307)
|
Документи
product_page
blueplanet gridsave Series - KACO new energy
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | One datasheet covers all three line voltages (400 V / 480 V / 600 V) at 50 Hz or 60 Hz, so the specification is not market-split; the individual model is selected by grid line voltage. |