Identity

category pv_modules
generation Hi-MO X6 Max Guardian (anti-dust design)
manufacturer LONGi
market_version IEC DC1500V
model LR7-54HTHF-475M
mpn —
product_family LR7-54HTHF 455~475M (Hi-MO X6 Max Guardian, Anti-Dust Frame)
product_status active
region GLOBAL
release_year 2024
series Hi-MO X6 Max
sku —
variant anti-dust frame

Electrical

application_class —
bifacial —
bifaciality_factor_pct —
cable_cross_section_mm2 4
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
cable_length_negative_mm 200
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
cable_length_positive_mm 400
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
cell_count 108
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
cell_technology Back-contact monocrystalline, 108 cells (6x18), single glass (Hi-MO X6 Max platform). The datasheet prints no cell-type row.
extra {'power_bins_w': [455, 460, 465, 470, 475], 'power_bin_table': [{'pmax_w': 455, 'model': 'LR7-54HTHF-455M', 'voc_v': 39.15, 'vmp_v': 32.98, 'isc_a': 14.79, 'imp_a': 13.8, 'efficiency_pct': 22.3}, {'pmax_w': 460, 'model': 'LR7-54HTHF-460M', 'voc_v': 39.35, 'vmp_v': 33.19, 'isc_a': 14.86, 'imp_a': 13.86, 'efficiency_pct': 22.5}, {'pmax_w': 465, 'model': 'LR7-54HTHF-465M', 'voc_v': 39.55, 'vmp_v': 33.39, 'isc_a': 14.93, 'imp_a': 13.93, 'efficiency_pct': 22.8}, {'pmax_w': 470, 'model': 'LR7-54HTHF-470M', 'voc_v': 39.75, 'vmp_v': 33.59, 'isc_a': 15.0, 'imp_a': 13.99, 'efficiency_pct': 23.0}, {'pmax_w': 475, 'model': 'LR7-54HTHF-475M', 'voc_v': 39.95, 'vmp_v': 33.79, 'isc_a': 15.07, 'imp_a': 14.06, 'efficiency_pct': 23.3}], 'noct_bin_table': [{'pmax_w': 340.0, 'model': 'LR7-54HTHF-455M', 'voc_v': 36.76, 'vmp_v': 30.09, 'isc_a': 11.95, 'imp_a': 11.3}, {'pmax_w': 343.7, 'model': 'LR7-54HTHF-460M', 'voc_v': 36.95, 'vmp_v': 30.29, 'isc_a': 12.0, 'imp_a': 11.35}, {'pmax_w': 347.4, 'model': 'LR7-54HTHF-465M', 'voc_v': 37.13, 'vmp_v': 30.47, 'isc_a': 12.06, 'imp_a': 11.41}, {'pmax_w': 351.2, 'model': 'LR7-54HTHF-470M', 'voc_v': 37.32, 'vmp_v': 30.65, 'isc_a': 12.12, 'imp_a': 11.45}, {'pmax_w': 354.9, 'model': 'LR7-54HTHF-475M', 'voc_v': 37.51, 'vmp_v': 30.83, 'isc_a': 12.17, 'imp_a': 11.51}], 'cell_count': '108 (6x18)', 'cell_layout': '108 (6x18)', 'fire_type': 'IEC Class C', 'bifacial_gain_note': 'No bifaciality statement or rear-gain table is printed on this datasheet.'}
imp_a 14.06
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
isc_a 15.07
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
junction_box_ip_rating IP68
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
max_reverse_current_a —
max_series_fuse_rating_a 25
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
max_system_voltage_label DC1500V (IEC)
max_system_voltage_v 1500
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
mechanical_load_front_pa 5400
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
mechanical_load_rear_pa 2400
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
module_efficiency_pct 23.3
module_type glass-backsheet
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
nmot {'pmax_w': 354.9, 'voc_v': 37.51, 'vmp_v': 30.83, 'isc_a': 12.17, 'imp_a': 11.51, 'conditions': 'NOCT: AM1.5, 800W/m2, 20 degC ambient, 1 m/s', 'note': '475M bin only.'}
nmot_c 45
official_product_url https://www.longi.com/en/products/modules-series/hi-mo-x6-max/
LONGi Hi-MO X6 Max
pmax_w 475
power_tolerance 0 ~ 3%
protection_class Class II
rated_power_w 475
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
stc_conditions AM1.5, 1000W/m2, 25 degC
temp_coeff_isc 0.05 %/degC
temp_coeff_pmax -0.28 %/degC
temp_coeff_voc -0.23 %/degC
vmp_v 33.79
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
voc_v 39.95
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
warranty_performance_years 25
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
warranty_product_years 15
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet

Physical / mechanical

backsheet —
bypass_diodes —
cable_cross_section_mm2 4.0
cable_length_mm 4mm2 output cable; +400, -200mm / +/-1200mm length can be customized
connector_type UNKNOWN - no connector brand or type is printed on this datasheet
depth_mm 30
dimensions_mm 1800x1134x30
frame Anodized aluminum alloy frame (anti-dust frame design: short side without A-side, so dust slides off under gravity and rainfall - per LONGi's Hi-MO X6 Max Guardian product page)
frame_colour —
glass Single glass, 3.2mm coated tempered glass
glass_construction single glass
glass_thickness_mm 3.2
height_mm 30
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
junction_box IP68
length_mm 1800
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
weight_kg 21.6
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
width_mm 1134
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet

Installation

clamp_requirements —
grounding —
max_installation_altitude_m —
mounting_methods —

Environment

ammonia —
fire_rating IEC Class C
hail 25mm Hailstone at the speed of 23m/s
max_static_load_front_pa 5400
max_static_load_rear_pa 2400
operating_temperature_c -40 to +85
operating_temperature_max_c 85
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
operating_temperature_min_c -40
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
pid —
salt_mist —
snow_load —
temperature_coefficient_isc_percent_c 0.05
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
temperature_coefficient_pmax_percent_c -0.28
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
temperature_coefficient_voc_percent_c -0.23
LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet
wind_load —

Certifications

standards ['IEC 61215', 'IEC 61730', 'ISO 9001:2015', 'ISO 14001:2015', 'ISO 45001:2018', 'IEC 62941']

Warranty & service

annual_degradation_pct 0.4
first_year_degradation_pct 1.0
performance_years 25
product_years 15
retained_power_at_year 25
retained_power_end_pct —

Документи

datasheet LR7-54HTHF 455~475M (Anti-dust Frame) - LONGi module datasheet rev V2 20240529
other LONGi Hi-MO X6 Max Guardian (anti-dust design) product page rev UNKNOWN
product_page LONGi Hi-MO X6 Max

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

Anti-dust frameShort side without A side design; patented frame and advanced sealing techniques ensure durability and load capacity