Identity

category pv_modules
generation M-G11
manufacturer Qcells
market_version IEC 1000 V
model Q.PEAK DUO BLK M-G11 400
mpn —
product_family Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp (30T)
product_status superseded
region EU
release_year —
series Q.PEAK DUO BLK M-G11
sku —
variant all-black (BLK)

Electrical

annual_degradation_percent 0.5
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
application_class —
bifacial False
bifaciality_factor_pct —
cable_length_negative_mm 1250
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
cable_length_positive_mm 1250
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
cell_count 108
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
cell_technology 6 x 18 monocrystalline Q.ANTUM solar half cells (108 cells), glass-backsheet, all-black
cell_type p-type PERC
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
connector_type Stäubli MC4 / Hanwha Q CELLS HQC4
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
extra {'power_bins_w': [380, 385, 390, 395, 400], 'power_bin_table': [{'pmax_w': 380, 'model': 'Q.PEAK DUO BLK M-G11 380', 'voc_v': 37.07, 'vmp_v': 30.31, 'isc_a': 13.26, 'imp_a': 12.54, 'efficiency_pct': 19.8}, {'pmax_w': 385, 'model': 'Q.PEAK DUO BLK M-G11 385', 'voc_v': 37.1, 'vmp_v': 30.54, 'isc_a': 13.3, 'imp_a': 12.61, 'efficiency_pct': 20.1}, {'pmax_w': 390, 'model': 'Q.PEAK DUO BLK M-G11 390', 'voc_v': 37.13, 'vmp_v': 30.77, 'isc_a': 13.34, 'imp_a': 12.68, 'efficiency_pct': 20.3}, {'pmax_w': 395, 'model': 'Q.PEAK DUO BLK M-G11 395', 'voc_v': 37.15, 'vmp_v': 30.99, 'isc_a': 13.37, 'imp_a': 12.75, 'efficiency_pct': 20.6}, {'pmax_w': 400, 'model': 'Q.PEAK DUO BLK M-G11 400', 'voc_v': 37.18, 'vmp_v': 31.21, 'isc_a': 13.41, 'imp_a': 12.82, 'efficiency_pct': 20.8}], 'nmot_bin_table': [{'pmax_w': 380, 'nmot_pmax_w': 285.1, 'nmot_voc_v': 34.96, 'nmot_vmp_v': 28.95, 'nmot_isc_a': 10.69, 'nmot_imp_a': 9.85}, {'pmax_w': 385, 'nmot_pmax_w': 288.8, 'nmot_voc_v': 34.99, 'nmot_vmp_v': 29.14, 'nmot_isc_a': 10.72, 'nmot_imp_a': 9.91}, {'pmax_w': 390, 'nmot_pmax_w': 292.6, 'nmot_voc_v': 35.01, 'nmot_vmp_v': 29.34, 'nmot_isc_a': 10.75, 'nmot_imp_a': 9.97}, {'pmax_w': 395, 'nmot_pmax_w': 296.3, 'nmot_voc_v': 35.04, 'nmot_vmp_v': 29.53, 'nmot_isc_a': 10.78, 'nmot_imp_a': 10.04}, {'pmax_w': 400, 'nmot_pmax_w': 300.1, 'nmot_voc_v': 35.07, 'nmot_vmp_v': 29.72, 'nmot_isc_a': 10.81, 'nmot_imp_a': 10.1}], 'cell_count': '108 (6 x 18)', 'cell_layout': '6 x 18 monocrystalline Q.ANTUM solar half cells', 'fire_type': 'C / TYPE 2 (per ANSI / UL 61730)', 'bifacial_gain_note': 'monofacial, glass-backsheet'}
first_year_degradation_percent 2.0
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
imp_a 12.82
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
isc_a 13.41
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
junction_box_ip_rating IP67
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
max_reverse_current_a 25
max_series_fuse_rating_a —
max_system_voltage_label Maximum System Voltage VSYS 1000 V
max_system_voltage_v 1000
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
mechanical_load_front_pa 5400
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
mechanical_load_rear_pa 3600
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
module_efficiency_pct 20.8
module_efficiency_percent ≥ 20.8
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
module_type monofacial
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
nmot {'pmax_w': 300.1, 'voc_v': 35.07, 'vmp_v': 29.72, 'isc_a': 10.81, 'imp_a': 10.1, 'conditions': 'NMOT: 800 W/m2, NMOT 43 +/- 3 degC, AM 1.5', 'note': '400 W bin only.'}
nmot_c 43
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
official_manual_url https://media.qcells.com/v/gtGCz022/
Qcells Installation and Operation Manual for the module series covering Q.PEAK DUO BLK M-G11 400
pmax_w 400
power_tolerance +5 W / -0 W
protection_class Class II (PV module classification)
rated_power_w 400
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
stc_conditions 1000 W/m2, 25 degC, AM 1.5
temp_coeff_isc 0.04 %/K
temp_coeff_pmax -0.34 %/K
temp_coeff_voc -0.27 %/K
vmp_v 31.21
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
voc_v 37.18
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
warranty_performance_years 25
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
warranty_product_years 12
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells

Physical / mechanical

backsheet Composite film
bypass_diodes —
cable_cross_section_mm2 4.0
cable_length_mm (+) >= 1250 mm, (-) >= 1250 mm
connector_type Staubli MC4, Hanwha Q CELLS HQC4
depth_mm 30
dimensions_mm 1692 mm x 1134 mm x 30 mm (including frame)
frame Black anodised aluminium
frame_colour black
glass 3.2 mm thermally pre-stressed glass with anti-reflection technology
glass_construction single glass
glass_thickness_mm 3.2
height_mm 30
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
junction_box 53-101 mm x 32-60 mm x 15-18 mm; IP67
length_mm 1692
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
weight_kg 21.2
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
width_mm 1134
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells

Installation

clamp_requirements —
grounding —
max_installation_altitude_m —
mounting_methods —

Environment

ammonia —
fire_rating C / TYPE 2 per ANSI / UL 61730
hail —
max_static_load_front_pa 5400
max_static_load_rear_pa 3600
operating_temperature_c -40 to +85
operating_temperature_max_c 85
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
operating_temperature_min_c -40
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
pid —
salt_mist —
snow_load Max. Test Load, Push / Pull 5400 / 3600 Pa; Max. Design Load, Push / Pull 3600 / 2400 Pa
temperature_coefficient_isc_percent_c 0.04
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
temperature_coefficient_pmax_percent_c -0.34
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
temperature_coefficient_voc_percent_c -0.27
Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells
wind_load see snow_load

Certifications

standards ['IEC 61215:2016', 'IEC 61730:2016', 'Quality Controlled PV - TUV Rheinland']

Warranty & service

annual_degradation_pct —
first_year_degradation_pct —
performance_years 25
product_years 12
retained_power_at_year 25
retained_power_end_pct —

Документи

datasheet Q.PEAK DUO BLK M-G11 SERIES 380-400 Wp | 108 Cells rev Q.PEAK_DUO_BLK_M-G11_series_380-400_30T_2022-06_Rev01_EN
installation-manual Qcells Installations- und Betriebsanleitung Q.PEAK DUO M-G11.X Solarmodul-Serie (Rev03, gültig ab 01.07.2022)
installation_manual Qcells Installation and Operation Manual for the module series covering Q.PEAK DUO BLK M-G11 400

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

Max. Design Load, Push / Pull3600 / 2400
Sheet code suffix30T