Qcells Q.PEAK DUO BLK ML-G10+/AC 415
Official manufacturer NA перевірено 22 вересня 2026 р.
Identity
| category | pv_modules |
| generation | ML-G10+ /AC (G10 platform) |
| manufacturer | Qcells |
| market_version | UL / North America, 1000 V DC module; 240 V 60 Hz AC output |
| model | Q.PEAK DUO BLK ML-G10+/AC 415 |
| model_variants_printed_on_datasheet | ['Q.PEAK DUO BLK ML-G10.C1+/AC', 'Q.PEAK DUO BLK ML-G10.D1+/AC'] |
| mpn | — |
| product_family | Q.PEAK DUO BLK ML-G10+/AC 395 - 415 Wp (AC module with integrated Q.MI.349B-G1 microinverter) |
| product_status | active |
| region | — |
| release_year | — |
| series | Q.PEAK DUO BLK ML-G10+/AC |
| sku | — |
| variant | AC module - factory-integrated microinverter |
Electrical
| application_class | — |
| bifacial | False |
| bifaciality_factor_pct | — |
| cable_length_negative_mm |
735
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| cable_length_positive_mm |
795
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| cell_count |
132
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| cell_technology | 6 x 22 monocrystalline Q.ANTUM solar half cells |
| cell_type |
p-type PERC
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| connector_type |
Stäubli MC4
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| extra | {'power_bins_w': [395, 400, 405, 410, 415], 'power_bin_table': [{'pmax_w': 395, 'model': 'Q.PEAK DUO BLK ML-G10+/AC 395', 'voc_v': 45.27, 'vmp_v': 36.88, 'isc_a': 11.1, 'imp_a': 10.71, 'efficiency_pct': '>= 20.1'}, {'pmax_w': 400, 'model': 'Q.PEAK DUO BLK ML-G10+/AC 400', 'voc_v': 45.3, 'vmp_v': 37.13, 'isc_a': 11.14, 'imp_a': 10.77, 'efficiency_pct': '>= 20.4'}, {'pmax_w': 405, 'model': 'Q.PEAK DUO BLK ML-G10+/AC 405', 'voc_v': 45.34, 'vmp_v': 37.39, 'isc_a': 11.17, 'imp_a': 10.83, 'efficiency_pct': '>= 20.6'}, {'pmax_w': 410, 'model': 'Q.PEAK DUO BLK ML-G10+/AC 410', 'voc_v': 45.37, 'vmp_v': 37.64, 'isc_a': 11.2, 'imp_a': 10.89, 'efficiency_pct': '>= 20.9'}, {'pmax_w': 415, 'model': 'Q.PEAK DUO BLK ML-G10+/AC 415', 'voc_v': 45.41, 'vmp_v': 37.89, 'isc_a': 11.23, 'imp_a': 10.95, 'efficiency_pct': '>= 21.1'}], 'cell_count': '132 (6 x 22)', 'cell_layout': '6 x 22 monocrystalline Q.ANTUM solar half cells', 'fire_type': 'C / TYPE 2 (ANSI / UL 61730)', 'ac_output': {'microinverter_model': 'Q.MI.349B-G1', 'peak_output_power_va': 366, 'max_continuous_output_power_va': 349, 'nominal_voltage_v': 240, 'voltage_range_v': '211 - 264', 'nominal_rated_output_current_a': 1.45, 'nominal_frequency_hz': 60, 'frequency_range_hz': '59.3 - 60.5', 'power_factor_adjustable': '0.85 leading to 0.85 lagging', 'power_factor_at_rated_power': 1.0, 'total_harmonic_distortion': '< 5 %', 'cec_efficiency_pct': 97, 'night_time_power_consumption_mw': 60, 'max_units_per_20a_branch_circuit': 11, 'microinverter_dimensions': '9.61 in x 5.79 in x 1.17 in (244 mm x 147 mm x 29.6 mm)', 'microinverter_protection_class': 'IP67 / NEMA Type 6'}} |
| imp_a |
10.95
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| isc_a |
11.23
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| junction_box_ip_rating |
IP68
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| max_reverse_current_a | — |
| max_series_fuse_rating_a |
20
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| max_system_voltage_label | 1000 V DC |
| max_system_voltage_v |
1000
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| mechanical_load_front_pa |
5400
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| mechanical_load_rear_pa |
5400
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| module_efficiency_pct | 21.1 |
| module_efficiency_percent |
≥ 21.1
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| module_efficiency_printed | >= 21.1 |
| module_type |
monofacial
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| nmot | {'pmax_w': 'UNKNOWN', 'voc_v': 'UNKNOWN', 'vmp_v': 'UNKNOWN', 'isc_a': 'UNKNOWN', 'imp_a': 'UNKNOWN', 'conditions': 'UNKNOWN', 'note': 'No NMOT electrical table could be read from the fetched AC module datasheet.'} |
| nmot_c | — |
| official_product_url |
https://us.qcells.com/q-peak-duo-blk-ml-g10-ac/
Q.PEAK DUO BLK ML-G10+/AC product page (Qcells North America)
|
| pmax_w | 415 |
| power_tolerance | — |
| protection_class | Class II |
| rated_power_w |
415
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| stc_conditions | STC (1000 W/m2, 25 +/- 2 degC) - DC module characteristics |
| temp_coeff_isc | 0.04 %/K |
| temp_coeff_pmax | -0.34 %/K |
| temp_coeff_voc | -0.27 %/K |
| vmp_v |
37.89
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| voc_v |
45.41
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| warranty_performance_years |
25
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| warranty_product_years |
25
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
Physical / mechanical
| backsheet | Composite film |
| bypass_diodes | printed as 'includes bypass diodes'; count not stated |
| cable_cross_section_mm2 | 4.0 |
| cable_length_mm | (+) >= 31.3 in (795 mm), (-) >= 28.9 in (735 mm) |
| connector_type | Staubli MC4; IP68 (DC connector) |
| depth_mm | 40 |
| dimensions_in | 74.0 in x 41.1 in x 1.57 in |
| dimensions_mm | 1879 x 1045 x 40 |
| frame | Black anodized aluminum |
| frame_colour | black |
| glass | 0.13 in (3.2 mm) thermally pre-stressed ARC solar glass |
| glass_construction | single glass |
| glass_thickness_mm | 3.2 |
| height_mm |
40
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| junction_box | 2.09-3.98 in x 1.26-2.36 in x 0.59-0.71 in (53-101 mm x 32-60 mm x 15-18 mm), protection class IP68, includes bypass diodes |
| length_mm |
1879
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| weight_kg |
23.75
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| weight_lbs | 52.36 |
| width_mm |
1045
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
Installation
| clamp_requirements | — |
| grounding | — |
| max_installation_altitude_m | — |
| mounting_methods | — |
Environment
| ammonia | — |
| fire_rating | ANSI / UL 61730 C / TYPE 2 |
| hail | — |
| max_design_load_push_pull | 75 lbs/ft2 (3600 Pa) push / 75 lbs/ft2 (3600 Pa) pull |
| max_static_load_front_pa | 5400 |
| max_static_load_rear_pa | 5400 |
| max_test_load_push_pull | 113 lbs/ft2 (5400 Pa) push / 113 lbs/ft2 (5400 Pa) pull |
| operating_temperature_c | -40 degF to +140 degF (-40 degC to +60 degC) permitted module operating temperature |
| operating_temperature_max_c |
60
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| operating_temperature_min_c |
-40
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| pid | — |
| salt_mist | — |
| snow_load | — |
| storage_temperature_c | -4 degF to +113 degF (-20 degC to +45 degC) |
| temperature_coefficient_isc_percent_c |
0.04
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| temperature_coefficient_pmax_percent_c |
-0.34
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| temperature_coefficient_voc_percent_c |
-0.27
Q.PEAK DUO BLK ML-G10+/AC series datasheet
|
| wind_load | — |
Certifications
| standards | ['UL 61730-1', 'UL 61730-2', 'CE-compliant', 'IEC 61215:2021', 'IEC 61730:2023', 'UL 1741', 'UL 1741SA', 'UL 1741SB', 'CSA C22.2 No. 107', 'IEEE 1547', 'UL listed as PV Rapid Shut Down Equipment (microinverter)'] |
Warranty & service
| annual_degradation_pct | 0.5 |
| first_year_degradation_pct | 2.0 |
| first_year_retained_pct | 98.0 |
| performance_years | 25 |
| product_years | 25 |
| retained_power_at_10_years_pct | 93.5 |
| retained_power_at_year | 25 |
| retained_power_end_pct | 86.0 |
| warranty_text | 25-year product and performance warranty, with an integrated module and microinverter solution from Qcells. At least 98 % of nominal DC power during first year, max 0.5 % degradation per year thereafter, at least 93.5 % up to 10 years, at least 86 % up to 25 years. |
Документи
datasheet
Q.PEAK DUO BLK ML-G10+/AC series datasheet
rev Q.PEAK_DUO_BLK_ML-G10.XY+_AC_395-415_2026-06_Rev04_NA
datasheet
Qcells Q.PEAK DUO BLK ML-G10+ series 395-420 Wp | 132 Cells (North America) — corroborating DC values
rev 2026-04 Rev01 NA
installation-manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Q.PEAK DUO BLK ML-G10+/AC installation manual — знайдено, не отримано
rev UNKNOWN
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| Datasheet file/revision code | Q.PEAK_DUO_BLK_ML-G10.XY+_AC_395-415_2026-06_Rev04_NA |
| Max Units per 20 A (L-L) Branch Circuit | 11 |
| Microinverter | Q.MI.349B-G1, 244 mm x 147 mm x 29.6 mm, IP67 / NEMA Type 6 |
| Night-Time Power Consumption | 60 mW |
| image_enrichment_pass | 2026-09-11 |