Qcells Q.PEAK DUO ML-G11S.2+ 510
Official manufacturer EU перевірено 22 вересня 2026 р.
Identity
| category | pv_modules |
| generation | ML-G11S.2+ |
| manufacturer | Qcells |
| market_version | IEC 1500 V |
| model | Q.PEAK DUO ML-G11S.2+ 510 |
| mpn | — |
| product_family | Q.PEAK DUO ML-G11S+ SERIES 490-510 Wp |
| product_status | active |
| region | EU |
| release_year | — |
| series | Q.PEAK DUO ML-G11S+ |
| sku | — |
Electrical
| application_class | — |
| bifacial | False |
| bifaciality_factor_pct | — |
| cable_length_negative_mm |
1415
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| cable_length_positive_mm |
1415
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| cell_count |
132
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| cell_technology | 6 x 22 monocrystalline Q.ANTUM solar half cells (132 cells), glass-backsheet |
| cell_type |
p-type PERC
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| connector_type |
Stäubli MC4-Evo2 / Hanwha Q CELLS HQC4
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| extra | {'power_bins_w': [490, 495, 500, 505, 510], 'power_bin_table': [{'pmax_w': 490, 'model': 'Q.PEAK DUO ML-G11S.2+ 490', 'voc_v': 45.3, 'vmp_v': 37.23, 'isc_a': 13.88, 'imp_a': 13.16, 'efficiency_pct': 20.7}, {'pmax_w': 495, 'model': 'Q.PEAK DUO ML-G11S.2+ 495', 'voc_v': 45.32, 'vmp_v': 37.44, 'isc_a': 13.91, 'imp_a': 13.22, 'efficiency_pct': 20.9}, {'pmax_w': 500, 'model': 'Q.PEAK DUO ML-G11S.2+ 500', 'voc_v': 45.35, 'vmp_v': 37.66, 'isc_a': 13.94, 'imp_a': 13.28, 'efficiency_pct': 21.1}, {'pmax_w': 505, 'model': 'Q.PEAK DUO ML-G11S.2+ 505', 'voc_v': 45.38, 'vmp_v': 37.87, 'isc_a': 13.97, 'imp_a': 13.34, 'efficiency_pct': 21.3}, {'pmax_w': 510, 'model': 'Q.PEAK DUO ML-G11S.2+ 510', 'voc_v': 45.41, 'vmp_v': 38.08, 'isc_a': 14.0, 'imp_a': 13.39, 'efficiency_pct': 21.5}], 'nmot_bin_table': [{'pmax_w': 490, 'nmot_pmax_w': 367.6, 'nmot_voc_v': 42.72, 'nmot_vmp_v': 35.52, 'nmot_isc_a': 11.18, 'nmot_imp_a': 10.35}, {'pmax_w': 495, 'nmot_pmax_w': 371.4, 'nmot_voc_v': 42.74, 'nmot_vmp_v': 35.71, 'nmot_isc_a': 11.21, 'nmot_imp_a': 10.4}, {'pmax_w': 500, 'nmot_pmax_w': 375.1, 'nmot_voc_v': 42.77, 'nmot_vmp_v': 35.89, 'nmot_isc_a': 11.23, 'nmot_imp_a': 10.45}, {'pmax_w': 505, 'nmot_pmax_w': 378.9, 'nmot_voc_v': 42.79, 'nmot_vmp_v': 36.07, 'nmot_isc_a': 11.26, 'nmot_imp_a': 10.5}, {'pmax_w': 510, 'nmot_pmax_w': 382.6, 'nmot_voc_v': 42.82, 'nmot_vmp_v': 36.25, 'nmot_isc_a': 11.28, 'nmot_imp_a': 10.55}], 'cell_count': '132 (6 x 22)', 'cell_layout': '6 x 22 monocrystalline Q.ANTUM solar half cells', 'fire_type': 'C / TYPE 1 (based on ANSI / UL 61730)', 'bifacial_gain_note': 'monofacial, glass-backsheet'} |
| first_year_degradation_percent |
2.0
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| imp_a |
13.39
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| isc_a |
14.0
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| junction_box_ip_rating |
IP67
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| max_reverse_current_a | 25 |
| max_series_fuse_rating_a | — |
| max_system_voltage_label | Maximum System Voltage VSYS [V] 1500 |
| max_system_voltage_v |
1500
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| mechanical_load_front_pa |
5400
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| mechanical_load_rear_pa |
3000
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| module_efficiency_pct | 21.5 |
| module_efficiency_percent |
≥ 21.5
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| module_type |
monofacial
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| nmot | {'pmax_w': 382.6, 'voc_v': 42.82, 'vmp_v': 36.25, 'isc_a': 11.28, 'imp_a': 10.55, 'conditions': 'NMOT: 800 W/m2, NMOT 43 +/- 3 degC, AM 1.5', 'note': '510 W bin only.'} |
| nmot_c |
43
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| official_manual_url |
https://media.qcells.com/v/z3tTjVwn/
Qcells Installation and Operation Manual for the module series covering Q.PEAK DUO ML-G11S.2+ 510
|
| pmax_w | 510 |
| power_tolerance | +5 W / -0 W |
| protection_class | Class II (PV module classification) |
| rated_power_w |
510
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| stc_conditions | 1000 W/m2, 25 degC, AM 1.5 |
| temp_coeff_isc | 0.04 %/K |
| temp_coeff_pmax | -0.34 %/K |
| temp_coeff_voc | -0.27 %/K |
| vmp_v |
38.08
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| voc_v |
45.41
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| warranty_performance_years |
25
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| warranty_product_years |
25
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
Physical / mechanical
| backsheet | Composite film |
| bypass_diodes | — |
| cable_cross_section_mm2 | 4.0 |
| cable_length_mm | (+) >= 1415 mm, (-) >= 1415 mm |
| connector_type | Staubli MC4-Evo2, Hanwha Q CELLS HQC4; IP68 |
| depth_mm | 30 |
| dimensions_mm | 2092 mm x 1134 mm x 30 mm (including frame) |
| frame | Anodised aluminium |
| frame_colour | — |
| glass | 3.2 mm thermally pre-stressed glass with anti-reflection technology |
| glass_construction | single glass |
| glass_thickness_mm | 3.2 |
| height_mm |
30
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| junction_box | 53-101 mm x 32-60 mm x 15-18 mm; IP67, with bypass diodes |
| length_mm |
2092
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| weight_kg |
25.7
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| width_mm |
1134
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
Installation
| clamp_requirements | — |
| grounding | — |
| max_installation_altitude_m | — |
| mounting_methods | — |
Environment
| ammonia | — |
| fire_rating | based on ANSI / UL 61730 |
| hail | — |
| max_static_load_front_pa | 5400 |
| max_static_load_rear_pa | 3000 |
| operating_temperature_c | -40 to +85 |
| operating_temperature_max_c |
85
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| operating_temperature_min_c |
-40
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| pid | — |
| salt_mist | — |
| snow_load | Max. Test Load, Push / Pull 5400 / 3000 Pa; Max. Design Load, Push / Pull 3600 / 2000 Pa |
| temperature_coefficient_isc_percent_c |
0.04
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| temperature_coefficient_pmax_percent_c |
-0.34
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| temperature_coefficient_voc_percent_c |
-0.27
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
|
| wind_load | see snow_load |
Certifications
| standards | ['IEC 61215:2016', 'IEC 61730:2016', 'Quality Controlled PV - TUV Rheinland', 'DIN EN 50380 (data sheet compliance)'] |
Warranty & service
| annual_degradation_pct | 0.5 |
| first_year_degradation_pct | — |
| performance_years | 25 |
| product_years | 25 |
| retained_power_at_year | 25 |
| retained_power_end_pct | 86 |
Документи
datasheet
Q.PEAK DUO ML-G11S.2+ MODEL 490-510 Wp | 132 Cells
rev Q.PEAK_DUO_ML-G11S+_series_490-510_2023-03_Rev03_EN
datasheet
Qcells Q.PEAK DUO ML-G11S series 495-515 Wp — corroborating 510 W column
rev 2023-06 Rev01 EN
datasheet
Qcells Specifiche Q.PEAK DUO ML-G11S SERIES 490-510 Wp (Italian edition, earlier revision)
rev Q.PEAK_DUO_ML-G11S_series_490-510_2023-01_Rev02_IT
Зафіксовані конфлікти
warranty.product_years Review required
25 — Q.PEAK_DUO_ML-G11S+_series_490-510_2023-03_Rev03_EN
12 — Q.PEAK_DUO_ML-G11S_series_490-510_2023-01_Rev02_IT
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| Classe di reazione al fuoco UNI 9177 (IT edition) | Classe 1 |
| Max. Design Load, Push / Pull | 3600 / 2000 |
| Performance warranty first year | At least 98 % of nominal power |
| Performance warranty year 10 | At least 93.5 % of nominal power |
| document_demoted_to_mirror | https://www.vpsolar.com/download/catalog/Moduli/QCells/Q.PEAK_DUO_ML-G11S/Qcells_Specifiche_Q.PEAK_DUO_ML-G11S_series_490-510_IT.pdf |