REC Group REC430AA Pure 2
Official manufacturer IEC / AU (CEC listed) перевірено 25 вересня 2026 р.
REC Group official REC Alpha Pure 2 product page; file name encodes REC_Alpha_Pure_2. Opened directly and inspected: all-black module on REC-branded background with the REC 25-year ProTrust warranty seal. Series photo shared across the Pure 2 power bins.
Identity
| category | pv_modules |
| generation | Alpha Pure 2 |
| manufacturer | REC Group |
| market_version | IEC 1000 V / UL 1000 V |
| model | REC430AA Pure 2 |
| mpn | REC430AA Pure 2 |
| product_family | REC Alpha Pure 2, RECxxxAA Pure 2, 400-430 W |
| product_status | active |
| region | IEC / AU (CEC listed) |
| release_year | 2024 |
| series | REC Alpha |
| sku | — |
Electrical
| application_class | — |
| bifacial | False |
| bifaciality_factor_pct | — |
| cable_length_negative_mm |
1200
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| cable_length_positive_mm |
1200
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| cell_count |
132
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| cell_technology | 132 half-cut bifacial REC heterojunction (HJT) cells суперечливе |
| cell_type |
HJT
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| connector_type | Stäubli MC4 PV-KBT4/KST4 |
| dimensions_mm | 1865x1040x30 |
| electrical_extra | {'power_tolerance': 'Watt class sorting 0/+10 W; tolerance on PMAX, VOC, ISC +-3% within one watt class', 'power_bins_w': [400, 410, 420, 430], 'power_density_w_per_m2': 222, 'max_reverse_current_a': 25, 'fire_rating': 'IEC 61730 Fire Type C (as per UL790); UL 61730 Fire Type 2'} |
| extra | {'power_bins_w': [400, 410, 420, 430], 'power_bin_table': [{'pmax_w': 400, 'model': 'REC400AA Pure 2', 'voc_v': 48.5, 'vmp_v': 40.2, 'isc_a': 10.72, 'imp_a': 9.96, 'efficiency_pct': 20.6, 'power_density_w_m2': 206}, {'pmax_w': 410, 'model': 'REC410AA Pure 2', 'voc_v': 48.8, 'vmp_v': 40.6, 'isc_a': 10.77, 'imp_a': 10.1, 'efficiency_pct': 21.1, 'power_density_w_m2': 211}, {'pmax_w': 420, 'model': 'REC420AA Pure 2', 'voc_v': 49.1, 'vmp_v': 41.2, 'isc_a': 10.83, 'imp_a': 10.2, 'efficiency_pct': 21.6, 'power_density_w_m2': 216}, {'pmax_w': 430, 'model': 'REC430AA Pure 2', 'voc_v': 49.3, 'vmp_v': 41.8, 'isc_a': 10.88, 'imp_a': 10.29, 'efficiency_pct': 22.2, 'power_density_w_m2': 222}], 'power_bin_table_nmot': [{'pmax_w': 400, 'nmot_pmax_w': 305, 'vmp_v': 37.9, 'imp_a': 8.04, 'voc_v': 45.7, 'isc_a': 8.66}, {'pmax_w': 410, 'nmot_pmax_w': 312, 'vmp_v': 38.3, 'imp_a': 8.16, 'voc_v': 46.0, 'isc_a': 8.7}, {'pmax_w': 420, 'nmot_pmax_w': 320, 'vmp_v': 38.8, 'imp_a': 8.24, 'voc_v': 46.3, 'isc_a': 8.75}, {'pmax_w': 430, 'nmot_pmax_w': 327, 'vmp_v': 39.4, 'imp_a': 8.31, 'voc_v': 46.5, 'isc_a': 8.79}], 'cell_count': '132 (half-cut)', 'cell_layout': 'UNKNOWN', 'power_density_w_m2': 222, 'fire_type': 'UL 61730 Fire Type 2 / IEC 61730 Fire Type C (as per UL790)', 'bifacial_gain_note': 'Datasheet describes the CELLS as bifacial heterojunction cells but the panel is built with an opaque black polymer backsheet and no module bifaciality factor is printed, so module-level bifaciality is recorded as UNKNOWN rather than guessed.'} |
| first_year_degradation_percent |
2.0
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| imp_a |
10.29
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| isc_a |
10.88
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| junction_box_ip_rating |
IP68
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| max_reverse_current_a | 25 |
| max_series_fuse_rating_a |
25
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| max_system_voltage_label | 1000 V |
| max_system_voltage_v |
1000
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| mechanical_load_front_pa |
7000
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| mechanical_load_rear_pa |
4000
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| module_efficiency_pct | 22.2 |
| nmot | {'pmax_w': 327, 'voc_v': 46.5, 'vmp_v': 39.4, 'isc_a': 8.79, 'imp_a': 8.31, 'conditions': 'NMOT: air mass AM 1.5, irradiance 800 W/m2, ambient temperature 20 degC, windspeed 1 m/s', 'note': 'Values for the 430 W bin only.'} |
| nmot_c | 44.0 |
| pmax_w | 430 |
| power_tolerance | 0/+10 W (Watt Class Sorting) |
| protection_class | — |
| rated_power_w |
430
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| stc_conditions | STC: air mass AM 1.5, irradiance 1000 W/m2, temperature 25 degC; production spread tolerance of PMAX, VOC & ISC +/-3% within one watt class |
| temp_coeff_isc | 0.04 %/degC |
| temp_coeff_isc_pct_per_c | 0.04 |
| temp_coeff_pmax | -0.24 %/degC |
| temp_coeff_pmax_pct_per_c | -0.24 |
| temp_coeff_voc | -0.24 %/degC |
| temp_coeff_voc_pct_per_c | -0.24 |
| vmp_v |
41.8
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| voc_v |
49.3
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC) — STC table, 430 W column, 'Open Circuit Voltage VOC'
|
| warranty_performance_years |
25
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
Physical / mechanical
| area_m2 | 1.94 |
| backsheet | Highly resistant polymer (Black) |
| bypass_diodes | 3 |
| cable_cross_section_mm2 | 4.0 |
| cable_length_mm | 1200 + 1200 (EN 50618:2014) суперечливе |
| connector_type | Staubli MC4 PV-KBT4/KST4 (4 mm2) in accordance with IEC 62852:2014, IP68 only when connected |
| depth_mm | 30 |
| dimensions_mm | 1865 x 1040 x 30 |
| enclosure_material | Anodized aluminum (Black) |
| frame | Anodized aluminum (Black) |
| frame_colour | Black |
| frame_height_mm | 28 mm and 45 mm (edge / corner measurements per the datasheet drawing) |
| glass | 3.2 mm solar glass with anti-reflective surface treatment суперечливе |
| glass_construction | single glass with opaque polymer back cover суперечливе |
| glass_thickness_mm | 3.2 |
| height_mm | 30 |
| junction_box |
3-part, IP68 rated, IEC 62790:2020
суперечливе
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC) — '3-part, 3 bypass diodes, IP68 rated, IEC 62790:2020'
|
| junction_box_diodes | 3 |
| length_mm |
1865
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| mounting_type | ['rooftop', 'ground'] |
| weight_kg |
21.7
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| width_mm |
1040
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
Installation
| clamp_requirements | — |
| grounding | — |
| max_installation_altitude_m | — |
| mounting_methods | — |
Environment
| ammonia | IEC 62716 Ammonia Resistance (Optional) |
| ammonia_resistance | IEC 62716 Ammonia Resistance (optional certification) |
| design_load_note | Design load = test load / 1.5 |
| fire_rating | IEC 61730 Fire Type C (as per UL790); UL 61730 Fire Type 2; ISO 11925-2 Ignitability (EN 13501-1 Class E) |
| hail | 35 mm @ 27.2 m/s |
| hail_rating |
35 mm @ 27.2 m/s per IEC 61215:2021
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC) — 'Max Hail Rating 35 mm @ 27.2 m/s'
|
| max_static_load_front_6point_pa | 8000 |
| max_static_load_front_pa | 7000 (4-point mounting, IEC61730/UL61730 certified); 8000 (6-point, internal testing) суперечливе |
| max_static_load_rear_6point_pa | 6000 |
| max_static_load_rear_pa | 4000 (4-point); 6000 (6-point, internal testing) суперечливе |
| nominal_operating_temperature_c | 44 +-2 |
| operating_temperature_c | -40 to +80 (T98) суперечливе |
| operating_temperature_max_c |
80
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| operating_temperature_min_c |
-40
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| pid | — |
| salt_mist | IEC 61701 Salt Mist - SM6 (Optional) |
| salt_mist_resistance | IEC 61701 Salt Mist SM6 (optional certification) |
| snow_load | Front (4-point) +7000 Pa / 714 kg/m2 |
| temperature_coefficient_isc_percent_c |
0.04
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| temperature_coefficient_pmax_percent_c |
-0.24
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| temperature_coefficient_voc_percent_c |
-0.24
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
|
| wind_load | Rear (4-point) -4000 Pa / 408 kg/m2 |
Certifications
| other | ['ISO 9001', 'ISO 14001', 'IEC 45001', 'IEC TS 63126 Level 1', 'ISO 11925-2 Ignitability (EN 13501-1 Class E)', 'IEC 61730 Fire Type C (as per UL790)'] |
| regional | ['AU CEC listed'] |
| safety | ['IEC 61215:2021', 'IEC 61730:2023', 'UL 61730'] |
| standards | ['ISO 14001', 'ISO 9001', 'IEC 45001', 'IEC 62941', 'IEC 61215:2021', 'IEC 61730:2023', 'UL 61730', 'IEC 61730 Fire Type C (as per UL790)', 'ISO 11925-2 Ignitability (EN 13501-1 Class E)', 'IEC 62716 Ammonia Resistance (Optional)', 'IEC 61701 Salt Mist - SM6 (Optional)', 'IEC 61215:2021 Hailstone (35 mm)', 'UL 61730 Fire Type 2', 'IEC TS 63126 Level 1'] |
Warranty & service
| annual_degradation_pct | 0.25 |
| conditional_terms | [{'condition': 'Standard warranty (panel NOT installed by an REC Certified Solar Professional)', 'product_years': 20, 'power_years': 25, 'labor_years': 0}, {'condition': 'REC ProTrust - installed by an REC Certified Solar Professional, all system sizes < 25 kW', 'product_years': 25, 'power_years': 25, 'labor_years': 25}, {'condition': 'REC ProTrust - installed by an REC Certified Solar Professional, 25 - 500 kW', 'product_years': 25, 'power_years': 25, 'labor_years': 10}] |
| conditions | REC ProTrust: 20 y product / 25 y power / 0 y labour for systems <25 kW not installed by an REC Certified Solar Professional; 25 y product / 25 y power / 10 y labour for 25-500 kW installed by an REC Certified Solar Professional. |
| end_of_warranty_output_pct | 92 |
| extended_options_years | [25] |
| first_year_degradation_pct | — |
| notes | Printed: Power in Year 1 98%; Annual Degradation 0.25%; >92% Power in Year 25. Condition printed on the datasheet: 'REC ProTrust Warranty applies only for i) REC panels installed by an REC Certified Solar Professional, and ii) panels have been registered by the installer with REC.' BOTH warranty lengths recorded: 20 y product standard / 25 y product with certified installation. |
| performance_years | 25 |
| product_years | 20 |
| product_years_certified_installer | 25 |
| retained_power_at_year | 25 |
| retained_power_end_pct | 92 |
| standard_years | 20 |
| year_one_output_pct | 98 |
Packaging & logistics
| pallets_per_40ft_container | 24 |
| units_per_136m_truck | 924 |
| units_per_40ft_container | 792 |
| units_per_pallet | 33 |
Документи
datasheet
REC Alpha Pure 2 Datasheet (IEC, EN, AU CEC)
rev IEC AU CEC 10.2025 V4.2, REF PM-DS-12-06/04.04.05.01
installation-manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
REC Alpha Pure Panels Installation Manual — знайдено, не отримано
product_page
REC Alpha Pure 2
Задокументована сумісність
Лише задокументовані пари. Якщо продукту тут немає, це означає, що не отримано документа, який називає цю пару, а не те, що вона несумісна.
pv_microinverter
Enphase IQ8+
COMPATIBLEinferred-from-electrical-parameters
Enphase IQ8 Series Microinverters datasheet IQ8SE-DS-0001-01-EN-US-2022-03-17, fetched https://enphase.com/sites/default/files/2021-10/IQ8-Series-DS-US.pdf ; REC Alpha Pure 2 datasheet IEC AU CEC 10.2025 V4.2
Зафіксовані конфлікти
physical.height_mm Resolved — accepted incoming value
1865 — stored value
30 — row 'Dimensions' (single row, all power classes): 1865 x 1040 x 30 mm (frame thickness 30 mm)
Detected during import pv-builder-2026-09-batch08
electrical.connector_type Resolved — accepted incoming value
Staubli MC4 PV-KBT4/KST4 (4 mm2), IEC 62852:2014, IP68 when connected — stored value
Stäubli MC4 PV-KBT4/KST4 — row 'Connectors' (single row, all power classes): 'Stäubli MC4 PV-KBT4/KST4 (4 mm²)'
Detected during import pv-builder-2026-09-batch08
electrical.nmot_c Resolved — accepted incoming value
44 — stored value
44.0 — row 'Nominal Module Operating Temperature (NMOT)' (single row, all power classes): 44 ± 2 °C — sheet prints NMOT, not NOCT
Detected during import pv-builder-2026-09-batch08
environment.max_static_load_rear_pa Review required
4000 (4-point); 6000 (6-point, internal testing) — stored value
4000 — incoming package
Detected during import pv-batch2-full-portfolio-2026-09-05
environment.max_static_load_front_pa Review required
7000 (4-point mounting, IEC61730/UL61730 certified); 8000 (6-point, internal testing) — stored value
7000 — incoming package
Detected during import pv-batch2-full-portfolio-2026-09-05
environment.operating_temperature_c Review required
-40 to +80 (T98) — stored value
Min environmental temperature -40 degC; module operating temperature [T98] 80 degC — incoming package
Detected during import pv-batch2-full-portfolio-2026-09-05
physical.cable_length_mm Review required
1200 + 1200 (EN 50618:2014) — stored value
1200 + 1200 — incoming package
Detected during import pv-batch2-full-portfolio-2026-09-05
physical.junction_box Review required
3-part, IP68 rated, IEC 62790:2020 — stored value
3-part, 3 bypass diodes, IP68 rated, in accordance with IEC 62790:2020 — incoming package
Detected during import pv-batch2-full-portfolio-2026-09-05
physical.glass_construction Review required
single glass with opaque polymer back cover — stored value
single glass — incoming package
Detected during import pv-batch2-full-portfolio-2026-09-05
physical.glass Review required
3.2 mm solar glass with anti-reflective surface treatment — stored value
3.2 mm solar glass with anti-reflective surface treatment in accordance with EN12150 — incoming package
Detected during import pv-batch2-full-portfolio-2026-09-05
electrical.cell_technology Review required
132 half-cut bifacial REC heterojunction (HJT) cells — stored value
132 half-cut REC bifacial heterojunction cells — incoming package
Detected during import pv-batch2-full-portfolio-2026-09-05
identity.product_family Resolved — kept current value
REC Alpha Pure 2, RECxxxAA Pure 2, 400-430 W — stored value
REC Alpha Pure 2 400-430 W — incoming package
Detected during import pv-batch2-full-portfolio-2026-09-05
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| Front / Rear (6-Point) load | +8000 Pa / -6000 Pa |
| Labor Warranty (yrs) | 0 (standard) / 25 (<25 kW certified) / 10 (25-500 kW certified) |
| Max Hail Rating | 35 mm @ 27.2 m/s |
| Module Current (compatible with MLPE) | 9 A |
| Module Operating Temperature [T98] | 80 degC |
| Nominal Module Operating Temperature | 44 +/- 2 degC |
| Panels per pallet / 40ft container / 13.6 m truck | 33 per pallet; 792 per 40ft container (24 pallets); 924 per 13.6 m truck (28 pallets) |
| Power in Year 1 | 98% |
| Product Warranty (yrs) | 20 (standard) / 25 (REC ProTrust, certified installer) |
| builder_completeness | partial |
| identity.region_as_researched | GLOBAL |