SolarEdge P605
Official manufacturer EU перевірено 20 вересня 2026 р.
Identity
| category | pv_optimizers |
| ean | — |
| firmware | {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'} |
| generation | — |
| manufacturer | SolarEdge |
| market_version | Power Optimizer For Europe (DS-000024-EU) |
| model | P605 |
| module_class | for 1 x high-power PV module |
| mpn | — |
| product_family | SolarEdge Power Optimizer |
| product_status | — |
| region | EU |
| release_year | — |
| series | P-Series |
| sku | — |
Electrical
| absolute_max_input_voltage_v | 65 |
| max_efficiency_pct | 99.5 |
| max_input_current_a | — |
| max_output_current_a | 15 |
| max_output_voltage_v | 80 |
| max_short_circuit_current_a | 14.1 |
| max_system_voltage_v | 1000 |
| mppt_operating_range_v | 12.5 - 65 |
| rated_input_dc_power_w | 605 |
| safety_output_voltage_v | 1 +/- 0.1 |
| weighted_efficiency_pct | 98.6 |
Physical / mechanical
| ac_terminal | — |
| cooling | — |
| dc_connector | MC4 (input and output) |
| depth_mm | — |
| dimensions_mm | 129 x 153 x 52 |
| display | — |
| enclosure_material | — |
| height_mm | 52.0 |
| input_wire_length_m | 0.16 |
| length_mm | 153.0 |
| mounting | — |
| noise_db | — |
| output_wire_length_m | Port: 1.4 / Land: 1.8 |
| weight_kg | 1.064 |
| weight_printed | 1064 gr |
| width_mm | 129.0 |
Installation
| cable_requirements | — |
| commissioning | — |
| installation_angle | — |
| mounting_clearances | — |
| torque | — |
Environment
| ingress_protection | IP68 / NEMA6P |
| max_altitude_m | — |
| operating_temperature_c | -40 to +85 |
| pollution_degree | — |
| protective_class | — |
| relative_humidity_pct | 0 - 100 |
| storage_temperature_c | — |
Interfaces & connectors
| app | — |
| communication | ['SolarEdge power-line communication over the DC string'] |
| dry_contact | — |
| meter_interface | — |
| monitoring_portal | — |
| protocols | [] |
Protection
| anti_islanding | — |
| arc_fault | — |
| dc_switch | — |
| insulation_monitoring | — |
| module_level_shutdown | Safety output voltage 1 +/- 0.1 Vdc per optimizer |
| overvoltage_category | II |
| rcmu | — |
| reverse_polarity | — |
| surge_protection_ac | — |
| surge_protection_dc | — |
Certifications
| standards | ['IEC 62109-1 (class II safety)', 'FCC Part 15', 'IEC 61000-6-2', 'IEC 61000-6-3 - Class B', 'EN 55011', 'RoHS', 'VDE-AR-E2100-712:2013-05'] |
Warranty & service
| conditions | — |
| extension_options | — |
| standard_years | 25 |
Документи
datasheet
Power Optimizer For Europe P605 / P650 / P701 / P730 / P800p / P801 / P850 / P950 / P1100
rev DS-000024-EU
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| Compatible inverters | read 1 (per-model): P605 -> SE20K, SE25K, SE27.6K, SE30K, SE33.3K, SE40K; P650/P701/P730/P801 -> SE16K and larger; P800p/P850/P950 -> SE16K and larger, SE20K and larger for some configurations; P1100 -> SE20K and larger. read 2 (coarse): P605-P801 -> 'Three Phase Inverter SE16K & larger'; P800p -> 'SE16K & larger'; P850/P950/P1100 -> 'SE20K & larger' |
| Footnote 1 | The rated power of the module at STC will not exceed the Power Optimizer's Rated Input DC Power. Modules with up to +5% power tolerance are allowed. |
| Footnote 6 | For ambient temperatures above +70 degC / +158 degF, power derating is applied. |
| Footnote 7 (mixing rule) | P650/P701/P730/P801 can be mixed in one string only with P650/P701/P730/P801. P605 cannot be mixed with any other Power Optimizer in the same string. P800p/P850/P950/P1100 can be mixed in one string only with P800p/P850/P950/P1100. |
| Footnote 9 | For SE16K and above, the minimum STC DC connected power should be 11KW. |
| Module class line | for 1 x high-power PV module |