Identity

category pv_optimizers
ean —
firmware {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'}
generation —
manufacturer SolarEdge
market_version Power Optimizer For Europe (DS-000024-EU)
model P701
module_class for up to 2 x 60/120-cell PV modules
mpn —
product_family SolarEdge Power Optimizer
product_status —
region EU
release_year —
series P-Series
sku —

Electrical

absolute_max_input_voltage_v 125
max_efficiency_pct 99.5
max_input_current_a —
max_output_current_a 15
max_output_voltage_v 80
max_short_circuit_current_a 11.75
max_system_voltage_v 1000
mppt_operating_range_v 12.5 - 105
rated_input_dc_power_w 700
safety_output_voltage_v 1 +/- 0.1
weighted_efficiency_pct 98.6

Physical / mechanical

ac_terminal —
cooling —
dc_connector MC4 (input and output)
depth_mm —
dimensions_mm 129 x 153 x 49.5
display —
enclosure_material —
height_mm 49.5
input_wire_length_m 0.16 / 0.9
length_mm 153.0
mounting —
noise_db —
output_wire_length_m Port: 1.2 / Land: 2.2
weight_kg 0.933
weight_printed 933 gr
width_mm 129.0

Installation

cable_requirements —
commissioning —
installation_angle —
mounting_clearances —
torque —

Environment

ingress_protection IP68 / NEMA6P
max_altitude_m —
operating_temperature_c -40 to +85
pollution_degree —
protective_class —
relative_humidity_pct 0 - 100
storage_temperature_c —

Interfaces & connectors

app —
communication ['SolarEdge power-line communication over the DC string']
dry_contact —
meter_interface —
monitoring_portal —
protocols []

Protection

anti_islanding —
arc_fault —
dc_switch —
insulation_monitoring —
module_level_shutdown Safety output voltage 1 +/- 0.1 Vdc per optimizer
overvoltage_category II
rcmu —
reverse_polarity —
surge_protection_ac —
surge_protection_dc —

Certifications

standards ['IEC 62109-1 (class II safety)', 'FCC Part 15', 'IEC 61000-6-2', 'IEC 61000-6-3 - Class B', 'EN 55011', 'RoHS', 'VDE-AR-E2100-712:2013-05']

Warranty & service

conditions —
extension_options —
standard_years 25

Документи

datasheet Power Optimizer For Europe P605 / P650 / P701 / P730 / P800p / P801 / P850 / P950 / P1100 rev DS-000024-EU

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

Compatible invertersread 1 (per-model): P605 -> SE20K, SE25K, SE27.6K, SE30K, SE33.3K, SE40K; P650/P701/P730/P801 -> SE16K and larger; P800p/P850/P950 -> SE16K and larger, SE20K and larger for some configurations; P1100 -> SE20K and larger. read 2 (coarse): P605-P801 -> 'Three Phase Inverter SE16K & larger'; P800p -> 'SE16K & larger'; P850/P950/P1100 -> 'SE20K & larger'
Footnote 1The rated power of the module at STC will not exceed the Power Optimizer's Rated Input DC Power. Modules with up to +5% power tolerance are allowed.
Footnote 6For ambient temperatures above +70 degC / +158 degF, power derating is applied.
Footnote 7 (mixing rule)P650/P701/P730/P801 can be mixed in one string only with P650/P701/P730/P801. P605 cannot be mixed with any other Power Optimizer in the same string. P800p/P850/P950/P1100 can be mixed in one string only with P800p/P850/P950/P1100.
Footnote 9For SE16K and above, the minimum STC DC connected power should be 11KW.
Module class linefor up to 2 x 60/120-cell PV modules