⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Smart Meters

Official manufacturer EU перевірено 25 вересня 2026 р.

Identity

category smart_meters
manufacturer Frer
model C70QPL005S4CAD
region EU
variant —

Electrical

accuracy_class C (kWh) EN 50470-3
C70-5M / C70-5S data sheet
accuracy_class_reactive 2 (kVArh) EN 62053-23
C70-5M / C70-5S data sheet
aux_supply_voltage_v 100...277 Vac
C70-5M / C70-5S data sheet
auxiliary_supply_voltage 100÷277 Vac
C70-5M / C70-5S data sheet
baud_rates_bps 600/1.2k/2.4k/4.8k/9.6k
C70-5M / C70-5S data sheet
bidirectional True
C70-5M / C70-5S data sheet
communication_port M-Bus EN 13757-3
C70-5M / C70-5S data sheet
connection_type CT (1 A / 5 A)
C70-5M / C70-5S data sheet
ct_input True
C70-5M / C70-5S data sheet
ct_primary_max_a 9999
C70-5M / C70-5S data sheet
ct_secondary_a 1-5
C70-5M / C70-5S data sheet
current_range_a 1-5
C70-5M / C70-5S data sheet
din_modules 4
C70-5M / C70-5S data sheet
frequency_hz 50/60
C70-5M / C70-5S data sheet
installation Indoor use
C70-5M / C70-5S data sheet
max_current_a 6
C70-5M / C70-5S data sheet
mbus True
C70-5M / C70-5S data sheet
minimum_current_a 0.05
C70-5M / C70-5S data sheet
nominal_voltage_v 3x230/400 суперечливе
C70-5M / C70-5S data sheet
operating_humidity_percent <95
C70-5M / C70-5S data sheet
phase_count 3
C70-5M / C70-5S data sheet
pulse_output Two S0 outputs (optoisolated); S01: programmable; S02: fixed to 3200 imp/kWh
C70-5M / C70-5S data sheet
pulse_output_count 2
C70-5M / C70-5S data sheet
reference_current_a 5
C70-5M / C70-5S data sheet
s0_pulse_outputs 2
C70-5M / C70-5S data sheet
starting_current_a 0.005
C70-5M / C70-5S data sheet
system_type Three-Phase 3/4-Wires
C70-5M / C70-5S data sheet
tariffs 2-4
C70-5M / C70-5S data sheet
transition_current_a 0.25
C70-5M / C70-5S data sheet
voltage_range 3x230/400 V ±20%
C70-5M / C70-5S data sheet
vt_primary_max_v 9999
C70-5M / C70-5S data sheet
vt_secondary_v 50÷230
C70-5M / C70-5S data sheet

Installation

mounting 4 modules
C70-5M / C70-5S data sheet

Environment

ip_rating IP51
C70-5M / C70-5S data sheet
ip_rating_terminals IP20
C70-5M / C70-5S data sheet
operating_temperature_max_c 70
C70-5M / C70-5S data sheet
operating_temperature_min_c -40
C70-5M / C70-5S data sheet
storage_temperature_max_c 75
C70-5M / C70-5S data sheet
storage_temperature_min_c -40
C70-5M / C70-5S data sheet

Interfaces & connectors

communications ['M-Bus']
C70-5M / C70-5S data sheet
documented_ports [{'port_role': 'PROPRIETARY_BUS', 'port_label_from_manual': 'M-bus', 'port_type': 'M-Bus', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': "row 'Communication', column 'C70-5S'", 'quote': 'Communication | M-bus'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'S0 Outputs', 'port_type': 'S0 pulse output', 'direction': 'output', 'electrical_domain': 'communication', 'quantity': 2, 'document': 0, 'page': "row 'S0 Outputs', column 'C70-5S'", 'quote': 'S0 Outputs | 2'}] суперечливе
modbus_rtu False
C70-5M / C70-5S data sheet
protocols ['M-Bus']
C70-5M / C70-5S data sheet
rs485 False
C70-5M / C70-5S data sheet

Certifications

mid_certified True
FRER MID energy meters index listing C70QPL005S4CAD

Документи

datasheet C70-5M / C70-5S data sheet
product_page FRER MID energy meters index listing C70QPL005S4CAD

Зафіксовані конфлікти

interfaces.documented_ports Review required
[{'port_role': 'PROPRIETARY_BUS', 'port_label_from_manual': 'M-bus', 'port_type': 'M-Bus', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': "row 'Communication', column 'C70-5S'", 'quote': 'Communication | M-bus'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'S0 Outputs', 'port_type': 'S0 pulse output', 'direction': 'output', 'electrical_domain': 'communication', 'quantity': 2, 'document': 0, 'page': "row 'S0 Outputs', column 'C70-5S'", 'quote': 'S0 Outputs | 2'}] — stored value
[{'port_role': 'PROPRIETARY_BUS', 'port_label_from_manual': 'M-Bus', 'port_type': 'M-Bus EN 13757-3', 'direction': 'BIDIRECTIONAL', 'electrical_domain': 'COMMUNICATION', 'document': 0, 'page': 'Communications, C70-5S column', 'quote': 'C70-5S: M-bus EN 13757-3'}, {'port_role': 'CT', 'port_label_from_manual': 'Current transformer input', 'port_type': 'CT secondary 1-5 A', 'direction': 'INPUT', 'electrical_domain': 'AC', 'document': 0, 'page': 'Transformers', 'quote': 'Current transformer primary: 9999 A; secondary: 1-5 A'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'S01', 'port_type': 'S0 optoisolated pulse output', 'direction': 'OUTPUT', 'electrical_domain': 'SIGNAL', 'document': 0, 'page': 'Pulse Outputs', 'quote': 'S01: programmable'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'S02', 'port_type': 'S0 optoisolated pulse output', 'direction': 'OUTPUT', 'electrical_domain': 'SIGNAL', 'document': 0, 'page': 'Pulse Outputs', 'quote': 'S02: fixed to 3200 imp/kWh'}] — incoming package
Detected during import deep-enrich-2026-09-batch25
electrical.nominal_voltage_v Review required
3x230/400 — stored value
400 — Nominal input voltage (Un): 3x230/400 V ±20%
Detected during import deep-enrich-2026-09-batch25

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesMID / EN 50470-3 European metering product; Italian manufacturer, EU market.
withheld:phase_count3