Janitza UMG 96-PA
Official manufacturer GLOBAL перевірено 25 вересня 2026 р.
Identity
| category | smart_meters |
| manufacturer | Janitza |
| model | UMG 96-PA |
| region | GLOBAL |
Electrical
| accuracy_class_active_energy |
0.2S (IEC 62053-22); 0.2 (IEC 61557-12); 0.2 (ANSI C12.20)
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| ct_secondary_current_a |
5
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| current_measuring_range_a |
0.005 .. 6 Arms
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| current_overload_1s_a |
60
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| digital_input_count |
3
UMG 96-PA | Technical data
|
| digital_output_count |
3
UMG 96-PA | Technical data
|
| direct_current_max_a |
Not applicable - the device is connected through external current transformers
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| frequency_hz |
45 Hz .. 65 Hz
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| harmonics_order |
1st - 40th
UMG 96-PA | Technical data
|
| local_modbus_available |
True
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| manufacturer_part_numbers |
['52.32.001', '52.32.002', '52.32.004', '52.32.010']
UMG 96-PA leaflet (EN)
|
| measurement_category |
600 V CAT III
UMG 96-PA | Technical data
|
| memory_mb |
8
UMG 96-PA | Technical data
|
| meter_type |
Panel-mounted modular power analyser (PMD), current-transformer connected
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| network_types |
TT-Net, TN-Net
UMG 96-PA | Technical data
|
| nominal_voltage_max_v |
up to 417 V / 720 V (three-phase 4-conductor)
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| panel_cutout_mm |
92+0.8 x 92+0.8
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| phase_count |
3
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| physical_interfaces |
['RS485', 'Ethernet']
UMG 96-PA | Technical data
|
| power_consumption |
max. 4.5 VA / 2 W
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| rated_current_a |
5
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| rs485_baud_rates |
9.6 kbps, 19.2 kbps, 38.4 kbps, 57.6 kbps, 115.2 kbps
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
| supply_voltage |
230 V option: AC 90 V - 277 V (50/60 Hz) or DC 90 V - 250 V, 300 V CATIII; 24 V option: AC 24 V - 90 V (50/60 Hz) or DC 24 V - 90 V, 150 V CATIII
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
Physical / mechanical
| depth_mm |
87.2
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
Interfaces & connectors
| cloud_required |
False
UMG 96-PA | Technical data
|
| documented_ports | [{'port_role': 'RS485', 'port_label_from_manual': 'RS-485', 'port_type': 'RS485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': 'Interfaces', 'quote': '"RS-485 - Modbus RTU/Slave 9.6 kbps, 19.2 kbps, 38.4 kbps, 57.6 kbps, 115.2 kbps"'}, {'port_role': 'ETHERNET', 'port_label_from_manual': 'Ethernet', 'port_type': 'Ethernet', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': None, 'document': 1, 'page': 'Technical data', 'quote': 'Interfaces: "RS485, Ethernet"; Protocols: "Modbus RTU, Modbus TCP/IP, Modbus Gateway"'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Digital inputs', 'port_type': 'digital input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 3, 'document': 0, 'page': 'Digital inputs and outputs', 'quote': 'Digital inputs: 3 inputs'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Digital / Pulse output', 'port_type': 'digital output', 'direction': 'output', 'electrical_domain': 'communication', 'quantity': 3, 'document': 0, 'page': 'Digital inputs and outputs', 'quote': 'Digital outputs: 3 outputs'}] |
| protocols |
['Modbus RTU (slave)', 'Modbus TCP/IP', 'Modbus Gateway']
UMG 96-PA | Technical data
|
Protection
| ingress_protection |
IP40 front (EN60529), IP54 front with seal, IP20 rear
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
|
Документи
datasheet
Power Analyzer UMG 96-PA (from Firmware 3.41) / UMG 96-PA-MID+ (from Firmware 3.41) - Data sheet
product_page
UMG 96-PA
product_page
UMG 96-PA leaflet (EN)
product_page
UMG 96-PA | Technical data
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | One worldwide specification: the data sheet prints IEC 62053-22, IEC 61557-12 and ANSI C12.20 accuracy classes for the same device, and 600 V CAT III on the technical-data page. |