LEM DCES 600
Manufacturer documented GLOBAL перевірено 25 вересня 2026 р.
Identity
| category | smart_meters |
| manufacturer | LEM |
| model | DCES 600 |
| region | GLOBAL |
| variant | — |
Electrical
| accuracy_class |
B; 1% for CTEP
суперечливе
DCES - DC energy sensor / meter series
|
| accuracy_percent |
1
DCES - DC energy sensor / meter series
|
| application |
Metering & Monitoring of DC systems (EVSE)
DCES - DC energy sensor / meter series
|
| dc_voltage_max_v |
1000
DCES - DC energy sensor / meter series
|
| direct_current_rating_a |
600
DCES - DC energy sensor / meter series
|
| duty |
permanent duty
DCES - DC energy sensor / meter series
|
| eichrecht |
True
DCES - DC energy sensor / meter series
|
| firmware_updatable |
True
DCES - DC energy sensor / meter series
|
| max_current_a |
600
DCES - DC energy sensor / meter series
|
| measurement_type |
DC
DCES - DC energy sensor / meter series
|
| meter_type |
DC energy meter
DCES - DC energy sensor / meter series
|
| mid_approved |
True
DCES - DC energy sensor / meter series
|
| ocmf_output |
True
DCES - DC energy sensor / meter series
|
Environment
| operating_temperature_max_c |
85
DCES - DC energy sensor / meter series
|
| operating_temperature_min_c |
-40
DCES - DC energy sensor / meter series
|
Interfaces & connectors
| communications |
['RS485']
DCES - DC energy sensor / meter series
|
| documented_ports | [{'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'RS-485 serial', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'main characteristics', 'quote': 'Metering and monitoring with APIs over RS485'}] |
| rs485 |
True
DCES - DC energy sensor / meter series
|
Certifications
| mid_certified |
True
DCES - DC energy sensor / meter series
|
| standards |
['MID 2014/32/EU', 'EN 50470-4:2023', 'Eichrecht', 'IEC 61000-6-2:2016', 'IEC 61000-6-3:2016', 'CISPR32 Class-B', 'UL94-V0', 'UL61010']
DCES - DC energy sensor / meter series
|
Документи
product_page
DCES - DC energy sensor / meter series
Зафіксовані конфлікти
interfaces.documented_ports Resolved — accepted incoming value
[{'port_role': 'RS485', 'port_label_from_manual': 'RS485 interface', 'port_type': 'RS485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Communications', 'quote': 'RS485 interface'}] — stored value
[{'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'RS-485 serial', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'main characteristics', 'quote': 'Metering and monitoring with APIs over RS485'}] — incoming package
Detected during import deep-enrich-2026-09-batch25
electrical.accuracy_class Review required
B; 1% for CTEP — stored value
B — Accuracy class B, 1% for CTEP
Detected during import deep-enrich-2026-09-batch25
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | One worldwide LEM product page; the page cites MID 2014/32/EU and Eichrecht, i.e. European legal metrology, but publishes no separate regional model. |