TENSE EM-07
Manufacturer documented GLOBAL
Identity
| category | smart_meters |
| manufacturer | TENSE |
| manufacturer_part_number | EM-07 |
| model | EM-07 |
| mpn | EM-07 |
| product_family | EM |
| product_status | active |
| region | GLOBAL |
| series | EM |
| variant | — |
Electrical
| accuracy_voltage_current |
+/-1 %
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
| ct_ratio_range |
1 ... 2000
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
| current_input_range |
50mA - 5,5A
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
| current_measurement_range |
50mA - 10.000A
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
| default_slave_id_register_map |
1
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| display |
71.5 x 61.5 mm Glass LCD
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
| measured_quantities |
per-phase V, I and frequency; per-phase apparent power S; min/max/average; demand; phase sequence; adjustable high/low voltage, current and frequency protection; phase-to-phase or phase-to-neutral protection; 1 adjustable relay output
EM-07 — official product page — Features
|
| operating_frequency |
50 / 60 Hz
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
| operating_voltage |
85V - 240V AC
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
| panel_cutout |
91mm x 91mm
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
| phases_supported_connection |
3P4W
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
| power_consumption |
<10 VA
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
| relay_outputs |
2A / 250V AC (resistive load)
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications - Output
|
| supported_slave_id_range_register_map |
1 - 247
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| voltage_measurement_range |
5V - 300V AC
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
| vt_ratio_range |
1 ... 999
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
Physical / mechanical
| weight |
<300 g
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
Installation
| mounting |
front panel mounted
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
Environment
| operating_altitude |
<2000 m
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
| operating_temperature |
-20 ... 55 degC
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
Interfaces & connectors
| communication_interface |
RS485 MODBUS RTU
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications - Communication
|
| device_type | three-phase digital multimeter with protection relay function, panel mount |
| modbus_function_codes_register_map |
not printed (NONE-forcing read returned NONE)
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| modbus_readable_registers_summary |
yes
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| modbus_register_address_base |
not stated; printed as an Address(Dec)/Address(Hex) pair running 4000-4143 dec
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| modbus_register_byte_order |
not stated
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| modbus_register_data_types |
per-row FORMAT column (16-bit and paired 32-bit high/low energy registers)
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| modbus_register_groups |
voltage and current transformer ratio; L-N and L-L voltages with avg/min/max; per-phase currents with avg/min/max/demand; active power and apparent power with avg/max/demand; per-phase frequency with avg/min/max; active energy (High/Low register pairs); reserved registers
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| modbus_register_map_available |
True
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| modbus_register_map_document_title |
MODBUS REGISTER TABLE EM-07
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| modbus_register_map_document_url | https://www.nwp-shop.de/mediafiles/Sonstiges/EM-XX%20XXX/EM-07K%20MODBUS%20REGISTER%20TABLE%20ENG.pdf |
| modbus_register_map_first_party_host |
False
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| modbus_register_map_note |
register CONTENTS deliberately not copied
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| modbus_register_map_retrieval_note |
TENSE-authored PDF read from the nwp-shop.de mirror; tense.com.tr blocks all *.pdf
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| modbus_register_table_columns |
ADDRESS (DEC) | ADDRESS (HEX) | REGISTER | R/W | RANGE | UNIT | MULTIPLIER | FORMAT
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| modbus_register_word_order |
not stated
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| modbus_rtu |
true
EM-07 — official product page — Features list
|
| modbus_rtu_role |
slave (Modbus device ID 1-247)
TENSE EM-07 User Manual (English) - ManualsLib HTML mirror — page 16 - Pr.52 Modbus ID
|
| modbus_slave_id_default |
1
TENSE EM-07 User Manual (English) - ManualsLib HTML mirror — page 16 - Pr.52
|
| modbus_slave_id_range |
1 - 247
TENSE EM-07 User Manual (English) - ManualsLib HTML mirror — page 16 - Pr.52
|
| modbus_writable_registers_summary |
yes - explicit R/W column
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror — Modbus register map metadata
|
| rs485 |
true
EM-07 — official product page — Features
|
| serial_baud_rate_default |
9600 bps
TENSE EM-07 User Manual (English) - ManualsLib HTML mirror — page 16 - Pr.53
|
| serial_baud_rate_range |
1200 - 38400 bps
TENSE EM-07 User Manual (English) - ManualsLib HTML mirror — page 16 - Pr.53
|
| serial_data_bits |
8
TENSE EM-07 User Manual (English) - ManualsLib HTML mirror — page 16 - 'Stopbits: 1, Party: none and Databits:8'
|
| serial_parity |
none (fixed)
TENSE EM-07 User Manual (English) - ManualsLib HTML mirror
|
| serial_stop_bits |
1 (fixed)
TENSE EM-07 User Manual (English) - ManualsLib HTML mirror
|
Protection
| ingress_protection |
IP41 (panel), IP20 (body)
TENSE EM-07 User Manual (English), DK-071-1 - nwp-shop.de mirror — Technical Specifications
|
Certifications
| certifications |
CE
TENSE Quality Certificates index - CE Certificate, EM Serisi — certificate list
|
Документи
manufacturer-document
TENSE EM-07 User Manual (English) - ManualsLib HTML mirror
modbus-register-map
MODBUS REGISTER TABLE EM-07 (EM-07K), TENSE-authored, nwp-shop.de mirror
product-page
EM-07 — official product page