⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Smart Meters

Manufacturer documented GLOBAL

Identity

category smart_meters
manufacturer TENSE
manufacturer_part_number TPM-01 ESH
model TPM-01 ESH
mpn TPM-01 ESH
product_family TPM-01
product_status active
region GLOBAL
series TPM-01
variant —

Electrical

default_slave_id_register_map not stated in the register document
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
display 4x4 digit LED
TPM-01 ESH — official product page — Features
harmonics_current up to 31st
TPM-01 ESH — official product page — Features
harmonics_voltage up to 31st
TPM-01 ESH — official product page — Features
measured_quantities per-phase P, Q (inductive/capacitive) and S; cos phi and power factor; per-phase V and I; total import/export active energy; total inductive/capacitive reactive energy; min/max; demand; V and I harmonics to 31st; event records (high/low V/I, voltage and current imbalance, THD-I)
TPM-01 ESH — official product page — Features
phases_supported_connection 3-phase voltage and 3-phase current transformers
TPM-01 ESH — official product page — Features
relay_outputs 2 relay outputs, 1 digital input
TPM-01 ESH — official product page — Features
supported_slave_id_range_register_map 1 - 247 (register 4057 / FD9 'Modbus ID')
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata

Interfaces & connectors

device_type three-phase multifunction energy analyzer, 4x4 digit LED display, panel mount
modbus_function_codes_register_map not printed - the string 'Function Code' does not appear anywhere in the document (NONE-forcing read)
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
modbus_readable_registers_summary yes - measurement registers are Read
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
modbus_register_address_base not stated in the document; addresses are printed as an explicit Address(Dec)/Address(Hex) pair running 4000-4419 dec (FA0-1143 hex)
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
modbus_register_byte_order not stated
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
modbus_register_data_types unsigned 16-bit, signed 16-bit, unsigned 32-bit (register pair), signed 32-bit (register pair), unsigned 64-bit (4 registers)
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
modbus_register_groups voltage (L-N, L-L, min/max/avg); current (per phase, neutral, total, max, demand); frequency; power factor; active/reactive/apparent power incl. demand; energy accumulators (import/export active, inductive/capacitive reactive, apparent); voltage and current harmonics by harmonic number; relay control and device configuration registers
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
modbus_register_map_available True
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
modbus_register_map_document_title Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
modbus_register_map_document_url https://www.nwp-shop.de/mediafiles/Sonstiges/TPM-04_-04SH_-04SH-DL/Modbus%20Register%20TPM-04%20SH%20SH-DL.pdf
modbus_register_map_first_party_host False
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
modbus_register_map_note register CONTENTS deliberately not copied; document link plus this metadata only, per spec
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
modbus_register_map_retrieval_note TENSE-authored PDF; tense.com.tr serves it only under a robots-disallowed *.pdf rule, so it was read from the German distributor mirror nwp-shop.de
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
modbus_register_table_columns Address (Dec) | Address (Hex) | Parameter | Data Type | Read/Write | Multiplier | Unit | Real Value
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
modbus_register_word_order not stated
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
modbus_rtu true
TPM-01 ESH — official product page — Features list
modbus_slave_id_range 1 - 247
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — register 4057 (FD9) Modbus ID
modbus_writable_registers_summary yes - the table carries an explicit Read/Write column with 'Read / Write' rows (configuration and relay registers)
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus register map metadata
rs485 true
TPM-01 ESH — official product page — Features
serial_baud_rate_range 1200 - 38400 bps
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Baudrate register
serial_parity_options None, Even, Odd (register-coded 1=None, 2=Even, 3=Odd)
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Modbus Parity register 4056 (FD8)
serial_stop_bits_options 1 - 2
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly — Stop Bits register

Certifications

certifications CE
TENSE Quality Certificates index - CE Certificate, TPM-01E/ES/ESH Series — certificate list

Документи

certificate TENSE Quality Certificates index - CE Certificate, TPM-01E/ES/ESH Series
modbus-register-map Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address - names this model explicitly
product-page TPM-01 ESH — official product page