Identity

category smart_meters
manufacturer TENSE
manufacturer_part_number TPM-04 SH
model TPM-04 SH
mpn TPM-04 SH
product_family TPM
product_status active
region GLOBAL
series TPM
variant —

Electrical

accuracy_active_energy +/-1 %
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
accuracy_reactive_energy +/-2 %
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
accuracy_voltage_current +/-0.5 %
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
ct_ratio_range 1 ... 1000
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications - Current Transformer Ratio
current_input_range 10mA - 5.5A
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
current_measurement_range 10mA - 5.500A
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
default_slave_id_register_map not stated in the register document
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
digital_inputs 1x 9V - 24V DC
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
display 71.5 x 61.5 mm Glass LCD
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
harmonics_current 3 - 31
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
harmonics_voltage 3 - 31
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
measured_quantities per-phase V, I, active power P, reactive power Q (inductive and capacitive), apparent power S, cos phi, power factor, total import/export active energy, total inductive/capacitive reactive energy, min/max, demand, voltage and current harmonics to 31st, event records
TPM-04 SH — official product page — Features
operating_frequency 50 / 60 Hz
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
operating_voltage 85V - 240V AC
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
panel_cutout 91mm x 91mm
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications - Panel Hole Sizes
phases_supported_connection 3P4W
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
power_consumption <10 VA
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
relay_outputs 2x 3A/250VAC (resistive load)
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
supported_slave_id_range_register_map 1 - 247 (register 4057 / FD9 'Modbus ID')
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
voltage_input_range 5V - 330V AC
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
voltage_measurement_range 5V - 330kV
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
vt_ratio_range 1,0 ... 999,9
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications - Voltage Transformer Ratio

Physical / mechanical

weight <300 g
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications

Installation

mounting front panel mounting
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications

Environment

operating_altitude <2000 m
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications
operating_temperature -20 ... 55 degC
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications

Interfaces & connectors

communication_interface RS485 MODBUS RTU
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications - Communication
device_type three-phase multifunction energy analyzer / network analyzer, panel mount
modbus_function_codes_register_map not printed - the string 'Function Code' does not appear anywhere in the document (NONE-forcing read)
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
modbus_readable_registers_summary yes - measurement registers are Read
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
modbus_register_address_base not stated in the document; addresses are printed as an explicit Address(Dec)/Address(Hex) pair running 4000-4419 dec (FA0-1143 hex)
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
modbus_register_byte_order not stated
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
modbus_register_data_types unsigned 16-bit, signed 16-bit, unsigned 32-bit (register pair), signed 32-bit (register pair), unsigned 64-bit (4 registers)
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
modbus_register_groups voltage (L-N, L-L, min/max/avg); current (per phase, neutral, total, max, demand); frequency; power factor; active/reactive/apparent power incl. demand; energy accumulators (import/export active, inductive/capacitive reactive, apparent); voltage and current harmonics by harmonic number; relay control and device configuration registers
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
modbus_register_map_available True
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
modbus_register_map_document_title Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
modbus_register_map_document_url https://www.nwp-shop.de/mediafiles/Sonstiges/TPM-04_-04SH_-04SH-DL/Modbus%20Register%20TPM-04%20SH%20SH-DL.pdf
modbus_register_map_first_party_host False
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
modbus_register_map_note register CONTENTS deliberately not copied; document link plus this metadata only, per spec
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
modbus_register_map_retrieval_note TENSE-authored PDF; tense.com.tr serves it only under a robots-disallowed *.pdf rule, so it was read from the German distributor mirror nwp-shop.de
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
modbus_register_table_columns Address (Dec) | Address (Hex) | Parameter | Data Type | Read/Write | Multiplier | Unit | Real Value
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
modbus_register_word_order not stated
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
modbus_rtu true
TPM-04 SH — official product page — Features list
modbus_rtu_role slave (addressed by ModBus ID 1-247)
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — RS485 communication parameters
modbus_slave_id_range 1 - 247
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — RS485 communication parameters
modbus_writable_registers_summary yes - the table carries an explicit Read/Write column with 'Read / Write' rows (configuration and relay registers)
Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address — Modbus register map metadata
rs485 true
TPM-04 SH — official product page — Features
serial_baud_rate_range 1200 - 38400 bps
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — RS485 communication parameters
serial_parity_options None, Even, Odd
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — RS485 communication parameters
serial_stop_bits_options 1 or 2
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — RS485 communication parameters

Protection

ingress_protection IP41 (front panel), IP20 (body)
TPM-04 SH User Manual (English), DK-088-3 - TENSE-authored PDF, read from the nwp-shop.de mirror — Technical Specifications

Certifications

certifications CE
TENSE Quality Certificates index - CE Certificate, TPM Series — certificate list

Документи

certificate TENSE Quality Certificates index - CE Certificate, TPM Series
modbus-register-map Tense TPM-04, TPM-04SH, TPM-01ES and TPM-01ESH Energy Analyser Basic Data Modbus Address
product-page TPM-04 SH — official product page