BYD Battery-Box Premium LVS (4.0-24.0 family, 16.0 kWh representative)

Official manufacturer GLOBAL verified Aug. 31, 2026

Identity

category batteries
manufacturer BYD
model Battery-Box Premium LVS (4.0-24.0 family, 16.0 kWh representative)
region GLOBAL

Electrical

chemistry LFP (LiFePO4, cobalt-free)
communication_can True
communication_rs485 True
firmware_requirements BYD Battery-Box Premium LVS Minimum Configuration List V1.11 (2024-01-16) states per-inverter minimum firmware, e.g. Victron MultiPlus/Quattro: BMU >= V1.16, BMS >= V1.8, inverter firmware >= V2.52; SMA SI 4.4M: BMU >= V1.19, BMS >= V1.8, inverter >= V1.3.1.R; Studer XTS1400-48: BMU >= V1.16, BMS >= V1.8, inverter >= R664; Deye SG01/SG03LP1: BMU >= V1.22, BMS >= V1.13, inverter >= C351; Deye SG04/SG05LP1 and SG04LP3: BMU >= V1.22, BMS >= V1.13, inverter >= 1001-C015; Solis RHI-3K-48ES-5G: BMU >= V1.19, BMS >= V1.08, inverter >= V330022; GoodWe ES/EM/BP/SBP: BMU >= V1.16, BMS >= V1.8, inverter >= ARM V11.
max_continuous_charge_current_a 250
max_continuous_discharge_current_a 250
max_continuous_power_kw 12.8
max_parallel_units 64
max_series_units N/A (LV parallel; 1-4 modules per tower)
min_series_units_hv N/A
nominal_energy_kwh 4.0-24.0 (modular family; representative unit 16.0 kWh)
nominal_voltage_v 51.2
officially_supported_inverter_brands ['Victron Energy', 'SMA', 'Studer', 'Deye', 'Solis', 'GoodWe', 'Selectronic']
officially_supported_inverter_models ['Victron MultiPlus 48/3000/35 and 48/5000/70; Multigrid 48/3000/35', 'Victron Quattro 48/5000/70-100/100, 48/8000/110-100/100, 48/10000/140-100/100, 48/15000/200-100/100', 'SMA SI 4.4M (Sunny Island)', 'Studer XTS1400-48 (and XT series)', 'Deye SUN-3.6/5/6/7.6/8K-SG01LP1-EU; SUN-12/14/16K-SG01LP1-EU; SUN-3.6/5/6K-SG03LP1-EU; SUN-3/3.6/5/6K-SG04LP1-EU; SUN-3.6/5/6/7.6/8K-SG05LP1-EU; SUN-5/6/8/10/12K-SG04LP3-EU', 'Solis RHI-3K-48ES-5G (and RHI 48ES-5G series)', 'GoodWe ES / EM / BP / SBP Series; GW3048-EM; GW3648-EM; GW5048-EM']
peak_current_a 360
supported_inverter_protocols ['CAN', 'RS485']
usable_energy_kwh matches nominal per BYD nameplate convention
voltage_class LV
voltage_range_v 40-57.6

Installation

minimum_module_count_rule BYD publishes a minimum LVS module count PER INVERTER AND PER APPLICATION (ON Grid / ON Grid + Backup / OFF Grid typical use / OFF Grid inrush power use) rather than a single figure. Examples: Victron Quattro 48/10000/140-100/100 needs >=1 module on-grid, >=5 modules and >=2 towers for on-grid+backup, >=4 modules off-grid typical and >=5 modules / >=2 towers for off-grid inrush (20 kW for 5 s); Deye SUN-12K-SG01LP1-EU needs >=5 modules for backup and >=7 modules / >=2 towers for off-grid inrush.

Documents

compatibility-list BYD BATTERY-BOX PREMIUM LVS MINIMUM CONFIGURATION LIST V1.11 rev V1.11