Deye RW-F10.2
Official manufacturer EU / AU (deye.com titles the product page 'RW-F10.2 (EU, AU)') verified Sept. 2, 2026
deye.com RW-F10.2 product page gallery
Identity
| category | batteries |
| ean | UNKNOWN |
| generation | UNKNOWN |
| manufacturer | Deye |
| market_version | UNKNOWN |
| model | RW-F10.2 |
| mpn | RW-F10.2 |
| product_family | Deye Spring RW-F series LFP wall/floor battery |
| product_revision | UNKNOWN |
| product_status | active |
| region | EU / AU (deye.com titles the product page 'RW-F10.2 (EU, AU)') |
| release_year | UNKNOWN |
| sku | UNKNOWN |
Electrical
| bms_architecture | {'type': 'self-contained wall/floor module with integrated BMS; RJ45 IN/OUT cascade for parallel packs', 'separate_master_bmu_required': False, 'external_controller': 'none required', 'modules_per_stack': 'N/A (parallel-only)', 'max_parallel_groups': '32 packs (326 kWh)'} |
| chemistry | LFP (LiFePO4) |
| communication_can | True |
| communication_rs485 | True |
| firmware_requirements | UNKNOWN |
| max_continuous_charge_current_a |
198
Deye ESS User Manual RW-F10.2 AU(EN) — manual p.7 spec table, 'Max Charge/Discharge Current 198A / 240A'
|
| max_continuous_discharge_current_a |
240
Deye ESS User Manual RW-F10.2 AU(EN) — manual p.7 spec table, 'Max Charge/Discharge Current 198A / 240A'
|
| max_continuous_power_kw | 6 ('Rated DC Power'); 12 ('Max DC Power') |
| max_parallel_units | 32 packs (326 kWh) |
| max_series_units | N/A (LV parallel-only architecture) |
| min_series_units_hv | N/A |
| nominal_energy_kwh | 10.2 |
| nominal_voltage_v | 51.2 |
| officially_supported_inverter_brands | ['Deye'] |
| officially_supported_inverter_models | ['Approved battery list DY-LV48-0109 lists RW-F10.2 (and RW-F10.2-B) among the Deye-brand batteries approved for: SUN-3.6/5/6/7.6/8K-SG01LP1-EU, SUN-5/6/7.6/8K-SG01LP1-US, SUN-3.6/5/6K-SG03LP1-EU, SUN-3/3.6/5/6K-SG04LP1-EU, SUN-3.6/5/6/7.6/8K-SG05LP1-EU, SUN-5/6/8/10/12K-SG04LP3-EU, SUN-12/14/16K-SG01LP1-EU, SUN-8K-SG02LP2-US, SUN-14/15/16/18/20K-SG05LP3-EU/AU-SM2'] |
| peak_current_a | UNKNOWN - see data_conflicts: the manual prints 240 A as the maximum DISCHARGE current while the global battery brochure prints 240 A as a 2-minute peak |
| supported_inverter_protocols | ["CAN 2.0 at 500 kbps (manual: 'baud rate: 500K')", 'RS485', "Deye inverter lithium-mode battery-protocol selection number 'CAN 00' per approved battery list DY-LV48-0109"] |
| usable_energy_kwh | 10.2 |
| voltage_class | LV |
| voltage_range_v |
44.8-57.6
Deye ESS User Manual RW-F10.2 AU(EN) — manual p.7, 'Operating Voltage 44.8~57.6 V'
|
Physical / mechanical
| depth_mm | 200 |
| height_mm | 760 |
| mounting_bolt_size | wall: M6*100 expansion bolts, 10 x M6 screws; floor: 2 x M6 screws |
| mounting_type | ['wall', 'floor'] |
| rack_units | N/A (wall/floor cabinet module) |
| shipping_weight_kg | UNKNOWN |
| terminal_locations | battery positive/negative terminals plus RJ45 inverter CAN/RS485 port and RJ45 parallel IN/OUT ports |
| torque_specs | UNKNOWN (no torque figures printed in the manual) |
| weight_kg | 104 |
| width_mm |
600
Deye ESS User Manual RW-F10.2 AU(EN) — manual p.7, 'Dimensions (W/H/D) 600*760*200 mm'
|
Installation
| clearance_note | manual p.13 clearance figure: A >= 70 mm, B >= 100 mm, C >= 40 mm, D >= 20 mm, E = 0-40 mm (letter-to-side mapping is a drawing, not printed as text) |
| ground_clearance_mm | 400 |
| indoor_outdoor | indoor and outdoor (IP65) |
| installation_temperature_range_c | -20 to +55 (manual: 'between -4 F and 131 F') |
| max_installation_altitude_m | 3000 |
| mounting_orientation | vertical, wall-mounted or floor-mounted |
| surface_requirements | clean, flat place with no direct sunlight |
| two_person_lift_required | UNKNOWN (unit weight 104 kg) |
| wall_hole_depth_mm | 100-110 |
Environment
| charge_temperature_c | 0 to +55 |
| cooling_method | natural convection |
| discharge_temperature_c | -20 to +55 |
| ip_rating | IP65 |
| max_altitude_m |
3000
Deye ESS User Manual RW-F10.2 AU(EN) — manual p.7, 'Altitude <=3000m'
|
| relative_humidity | 5%-95% |
| storage_temperature_c | 0 to +35 |
Interfaces & connectors
| can | yes - CAN 2.0, 500 kbps, RJ45 |
| protocol_notes | Separate RJ45 inverter CAN/RS485 port plus RJ45 parallel IN/OUT cascade ports. No DIP-switch addressing described. |
| rs485 | yes |
Protection
| cell_balancing | yes (intelligent BMS; algorithm not documented) |
| integrated_breakers_fuses | micro circuit breaker present; amperage rating NOT printed in the manual |
| over_current | yes |
| over_temperature | yes - high and low temperature protection |
| over_voltage | yes - charge over-voltage |
| short_circuit | yes |
| under_voltage | yes - discharge under-voltage |
Certifications
| emc | [] |
| grid_codes | ['CEI 0-21'] |
| other | ['CEC'] |
| regional | ['CE'] |
| safety | ['IEC 62619', 'VDE 2510-50'] |
| transport | ['UN38.3'] |
Warranty & service
| cycle_life | 6000 cycles at 90% DoD (manual); the global battery brochure prints '>=6000 (25 C +/- 2 C, 0.5C/0.5C, 70% EOL)' for the RW family |
| design_life_years | UNKNOWN |
| round_trip_efficiency | UNKNOWN |
| standard_years | 10 |
Packaging & logistics
| gross_weight_kg | UNKNOWN (unit weight 104 kg) |
| transport_restrictions | UN38.3 (UN3480 Class 9 lithium battery) |
Documents
Recorded conflicts
nominal_energy_kwh Review required
10.2 — user manual spec table p.7 ('Energy 10.2 kWh')
10.24 — Deye global battery brochure 20250925 EN (RW-L10.2 / RW-F10.2 family rows print 10.24 kWh)
rounding of 200 Ah x 51.2 V = 10.24 kWh; the manual rounds to 10.2
peak_current_a Review required
240 A = Max discharge current (continuous rating) — Deye ESS User Manual RW-F10.2 AU(EN), spec table p.7
240 A = peak (2 mins) — Deye global battery brochure 20250925 EN, RW-F10.2 column
the brochure's family table compresses the manual's separate 'max' and 'peak' rows; document revision difference
peak_current_a Review required
240 A = Max discharge current (continuous rating) — Deye ESS User Manual RW-F10.2 AU(EN), spec table p.7
240 A = peak (2 mins) — Deye global battery brochure 20250925 EN, RW-F10.2 column
the brochure's family table compresses the manual's separate 'max' and 'peak' rows; document revision difference
nominal_energy_kwh Review required
10.2 — user manual spec table p.7 ('Energy 10.2 kWh')
10.24 — Deye global battery brochure 20250925 EN (RW-L10.2 / RW-F10.2 family rows print 10.24 kWh)
rounding of 200 Ah x 51.2 V = 10.24 kWh; the manual rounds to 10.2
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Ground clearance | more than 400mm |
| Max DC Power | 12 kW |
| Rated DC Power | 6 kW |