Dyness Powerbox G2
Official manufacturer Global verified Sept. 2, 2026
Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.
UNKNOWN
Identity
| category | batteries |
| ean | UNKNOWN |
| generation | G2 |
| hardware_revision | UNKNOWN |
| legacy_name | Superseded in the current catalogue by the PowerBox G3 (same 51.2 V / 200 Ah / 10.24 kWh format, 730 mm tall / 100 kg versus the G2's 640 mm / 96 kg), but the G2 remains listed as an active product. |
| manufacturer | Dyness |
| market_version | UNKNOWN |
| model | Powerbox G2 |
| mpn | UNKNOWN |
| product_family | Dyness PowerBox series (PowerBox G2 / PowerBox Pro / PowerBox G3) disputed |
| product_revision | G2 |
| product_status | active |
| product_status_detail | active (listed on dyness.com low-voltage residential index as of 2026-09-01) |
| product_status_evidence | Live official product page at https://dyness.com/powerbox-g2-low-voltage-storage-batteries-household-use fetched 2026-09-02, still publishing a full specification table and a 10-year warranty. Also named as a supported expansion system on the current official Dyness LV-Link A page. NOTE: the same URL with a 'www.' prefix returns HTTP 404, and the product did not appear in the fetched rendering of the dyness.com low-voltage index or the download centre - so a delisting conclusion drawn from those two sources alone would be wrong. |
| region | Global |
| release_year | UNKNOWN |
| sku | UNKNOWN |
| subcategory | low-voltage 48V-class wall/floor mounted battery |
| variant_note | One capacity/voltage variant (51.2 V / 200 Ah / 10.24 kWh). |
Electrical
| bms_architecture | {'type': 'master/slave over CAN; master aggregates system data and talks to the inverter', 'separate_master_bmu_required': False, 'address_setting': '4-position DIP (positions #1-#4) select protocol group and baud rate', 'modules_per_stack': 'N/A (self-contained wall unit)', 'max_parallel_groups': 'up to 40 Powerbox G2 in parallel (user manual p.22-24)'} |
| cell_chemistry | LFP (LiFePO4) |
| cell_type | UNKNOWN |
| chemistry | LFP |
| communication_can | True |
| communication_rs485 | True |
| continuous_charge_current_a | 200 |
| continuous_discharge_current_a | 200 |
| continuous_power_kw | 10.24 |
| cycle_life | >=8000 cycles / 10 Years |
| depth_of_discharge_pct | 95 |
| firmware_requirements | UNKNOWN |
| max_charge_c_rate | 1C |
| max_charge_current_a | 200 |
| max_charge_power_kw | UNKNOWN |
| max_continuous_charge_current_a |
200
Dyness Powerbox G2 User Manual — Table 2-2 p.7, 'Max Charging Current 200A'
|
| max_continuous_discharge_current_a |
200
Dyness Powerbox G2 User Manual — Table 2-2 p.7, 'Max Discharge Current 200A'
|
| max_continuous_power_kw | 10.24 |
| max_discharge_current_a | 200 |
| max_discharge_power_kw | 10.24 ('Maximum Output') |
| max_parallel_units | 50 disputed |
| max_series_units | N/A (LV parallel stack) |
| min_series_units_hv | N/A |
| nominal_capacity_ah | 200 |
| nominal_energy_kwh | 10.24 |
| nominal_voltage_v | 51.2 |
| note | The G2 publishes SYMMETRIC 200 A charge and discharge limits (unlike the PowerDepot G2, whose charge limit of 75 A is lower than its 100 A discharge limit) - do not generalise across Dyness LV models. The 300 A figure is a 2-minute peak DISCHARGE current at 25C. 409.6 kWh / 10.24 kWh = 40 units, which contradicts the same page's '50 units in parallel'. |
| officially_supported_inverter_brands | ['SMA', 'Victron', 'Ingeteam', 'Solis', 'GoodWe', 'Growatt', 'Deye', 'Sofar', 'SAJ', 'Solplanet'] |
| officially_supported_inverter_models | UNKNOWN (brand-level only) |
| operating_voltage_max_v | 57.6 |
| operating_voltage_min_v | 44.8 |
| parallel_supported | yes |
| peak_charge_current_a | UNKNOWN |
| peak_current_a |
300 (2 min, 25 C)
Dyness Powerbox G2 User Manual — Table 2-2 p.7, 'Peak Discharge Current 300(2mins,25C)'
|
| peak_discharge_current_a | 300 (2 min, 25C) |
| peak_power_kw | UNKNOWN |
| protocol_dialects | {'values': ['CAN 500K (DIP OFF) or 250K (DIP ON); RS485 9600 (OFF) or 115200 (ON)', 'DIP 0000 (factory default): GOODWE, Solis, LUX, Sofar, DEYE(Sunsynk), VICTRON, IMEON, Sungrow, SMA, RENAC, DELIOS, SAJ (CAN Comm)', 'DIP #2 ON: Axpert-king/VMIII/MAX, Infinisolar, Growatt SPH/SPA (CAN), GMDE', 'DIP #2 & #3 ON: Growatt SPF HVM-P/ES/WPV (RS485)', 'DIP #1 & #3 ON: Schneider Conext Series'], 'note': 'Verbatim inverter-protocol dialect list from the manufacturer document. The flat supported_inverter_protocols field keeps the coarse physical-layer list that downstream consumers parse.', 'evidence': "Dyness Powerbox G2 User Manual EN V1 fetched 2026-09-01 (Nastech Solar mirror; dyness.com PDFs are robots-blocked to WebFetch). Verbatim Table 2-2 p.7: 'Nominal Voltage 51.2V'; 'Work Voltage Range 44.8~57.6V'; 'Nominal Capacity 200Ah'; 'Nominal Energy 10.24 kWh'; 'Nominal Power 5.12 kW'; 'Peak Power"} |
| round_trip_efficiency_pct | UNKNOWN |
| series_supported | no (low-voltage parallel-only architecture) |
| supported_inverter_protocols |
['CAN', 'RS485']
Dyness Powerbox G2 User Manual — Table 3-4 p.23 DIP protocol table
|
| system_energy_max_kwh | 409.6 |
| system_energy_min_kwh | 10.24 |
| usable_energy_kwh | 9.728 |
| voltage_class | LV |
| voltage_range_v | 44.8-57.6 |
Physical / mechanical
| cooling_method | natural convection |
| depth_mm | 165 |
| height_mm | 640 |
| installation_notes | See the existing ANMA record for bracket, bolt and torque detail from the user manual. |
| ip_rating | IP65 |
| mounting_bolt_size | wall bracket: 4 x M6 expansion screws; unit: six M8 step screws |
| mounting_hole_diameter_mm | 10 |
| mounting_hole_spacing_mm | UNKNOWN (bracket template: bottom of the cardboard template ~300 mm from the ground; holes 10 mm diameter, >70 mm deep) |
| mounting_type | ['wall', 'floor'] |
| rack_units | N/A (wall-mount enclosure) |
| shipping_weight_kg | UNKNOWN |
| terminal_locations | waterproof power connectors; power cable cross-section 35 mm2 |
| torque_specs |
M8 step screws 11.8 N.m; M6 wall bracket expansion screws 9.8 N.m
Dyness Powerbox G2 User Manual — manual p.17-18
|
| weight_kg | 96 |
| width_mm | 710 |
Installation
| indoor_outdoor | indoor and outdoor (IP65) |
| installation_humidity_range | 5%-85% RH |
| installation_notes | max installation altitude 4000 m; installation humidity 5%-85% RH (existing ANMA record, from the user manual) |
| max_installation_altitude_m | 4000 |
| mounting_orientation | vertical wall mount or floor |
Environment
| charge_temperature_c | 0 to +55 |
| charge_temperature_range_c | CONFLICT - see data_conflicts (user manual 0C to +55C; official page '-20C to 55C (optional)' with built-in heating) |
| cooling_method | natural convection |
| discharge_temperature_c | -20 to +55 |
| discharge_temperature_range_c | -20C to +55C |
| indoor_outdoor | indoor and outdoor (IP65) |
| ip_rating |
IP65
Dyness Powerbox G2 User Manual — manual p.5
|
| max_altitude_m | 4000 |
| operating_humidity | 5%-85% RH |
| operating_temperature_max_c | 55 |
| operating_temperature_min_c | -20 |
| relative_humidity | 5%-85% RH |
| storage_temperature_c | -10 to +35 |
| storage_temperature_max_c | 35 |
| storage_temperature_min_c | -10 |
Interfaces & connectors
| bluetooth | UNKNOWN |
| can | yes - COM IN / COM OUT; EXT CANH pin4, CANL pin5; INT CANH pin7, CANL pin8; 500K or 250K disputed |
| communication_ports | CAN / RS485 (+ Wi-Fi module) |
| dry_contact | UNKNOWN |
| ethernet | UNKNOWN |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| protocol_notes | 4-position DIP switch selects the inverter protocol group and baud rate (Table 3-4, manual p.23). disputed |
| rs232 | UNKNOWN |
| rs485 | yes - 485B pin1, 485A pin2; 9600 or 115200 bps disputed |
| usb | UNKNOWN |
| wifi | yes (WiFi module) |
Protection
| auto_shutdown | dormant standby after more than 72 hours idle |
| fire_suppression | UNKNOWN from the official page (the newer G3 documents a built-in aerosol fire extinguisher; do not assume the G2 has one) |
| heating | yes - 'Built-in Heating: Reliable performance at low temperatures' (shop-rebor.com, distributor-verified); corroborated by the official page's '-20C (optional)' charging temperature |
| integrated_breakers_fuses | integrated DC circuit breaker (component #3, manual p.8); ampere rating not printed |
| ip_rating | IP65 |
| over_current | charge >210 A -> current limited to <=5 A; discharge >215 A -> discharge stops disputed |
| over_temperature | charge window 0-55 C; discharge window -20 to +55 C disputed |
| over_voltage | yes |
| short_circuit | yes - via the integrated DC circuit breaker |
| under_voltage | yes |
Certifications
| confidence | distributor-verified (CE / UN38.3 / IEC62619 / IEC62040 from shop-rebor.com) and manufacturer-documented (RoHS / SGS from the user manual) |
| emc | [] |
| note | The Powerbox G2 user manual prints only 'Comply with European ROHS, Certified SGS' (p.5) and 'meets European directive requirements' (p.6). No UN38.3/IEC 62619 identifier appears in this document. disputed |
| other | ['SGS certified'] |
| regional | ['European RoHS'] |
| safety | [] |
| safety_certifications | ['CE'] |
| standards | ['IEC62619', 'IEC62040'] |
| transport | [] |
| transport_certifications | ['UN38.3'] |
Warranty & service
| conditions | UNKNOWN |
| confidence | officially-verified |
| cycle_life | UNKNOWN (not stated in the user manual) |
| design_life_years | UNKNOWN |
| note | WARRANTY CROSS-CHECK: the task flagged a known dyness.com vs dyness.us warranty disagreement. No conflict was found for the PowerBox G2 - dyness.com states 10 years, and the nearest dyness.us product (PowerBox-US, a distinct US-market model) also states '10-year warranty'. No conflict recorded. |
| self_discharge | recharging period can be up to 10 months (manual p.5) |
| summary | 'Warranty' = '10 years' on the official dyness.com PowerBox G2 product page. |
| years | 10 |
Packaging & logistics
| gross_weight_kg | UNKNOWN |
| transport_restrictions | UNKNOWN (no UN38.3 or Class 9 statement in the user manual) |
Documents
datasheet
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Powerbox G2 Datasheet-EN-20250627 — located, not retrieved
rev 20250627
distributor-page
Dyness Powerbox G2 10.24kWh - distributor product page (shop-rebor.com)
rev UNKNOWN
product-page
Dyness LV-Link A official product page (names PowerBox G2 in 'Expansion System Compatibility')
rev UNKNOWN
product-page
Dyness Powerbox G2 - Wall-Mounted 51.2V LiFePO4 Home Battery (official product page)
rev UNKNOWN
user-manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Dyness PowerBox G2 User Manual, EN V1 (official dyness.com copy) — located, not retrieved
rev EN V1
Recorded conflicts
environment.charge_temperature_range_c Review required
0C to +55C — Dyness Powerbox G2 User Manual EN V1 (via the existing ANMA record)
-20C ('Charging Temperature: -20C'; the page also gives 'Operating Temperature: -20C to 55C (optional)') — Dyness official PowerBox G2 product page
electrical.max_parallel_units Review required
40 — Dyness Powerbox G2 User Manual EN V1, p.22-24, 'supports up to 40 Powerbox G2 in parallel' (via the existing ANMA record)
50 — Dyness official PowerBox G2 product page, 'Expansion Capacity' = '10.24kWh to 409.6kWh (up to 50 parallel units)'
certifications.note Review required
The Powerbox G2 user manual prints only 'Comply with European ROHS, Certified SGS' (p.5) and 'meets European directive requirements' (p.6). No UN38.3/IEC 62619 identifier appears in this document. — stored value
The official dyness.com G2 page prints no certification list. Not officially verified. — incoming package
Detected during import dyness-full-portfolio-2026-09-02
protection.over_temperature Review required
charge window 0-55 C; discharge window -20 to +55 C — stored value
yes — incoming package
Detected during import dyness-full-portfolio-2026-09-02
protection.over_current Review required
charge >210 A -> current limited to <=5 A; discharge >215 A -> discharge stops — stored value
charge >210 A -> current limited to <=5 A; discharge >215 A -> discharge stops (existing ANMA record, from the user manual) — incoming package
Detected during import dyness-full-portfolio-2026-09-02
interfaces.protocol_notes Review required
4-position DIP switch selects the inverter protocol group and baud rate (Table 3-4, manual p.23). — stored value
4-position DIP switch selects the inverter protocol group and baud rate (user manual Table 3-4, p.23) - see the existing ANMA record. — incoming package
Detected during import dyness-full-portfolio-2026-09-02
interfaces.rs485 Review required
yes - 485B pin1, 485A pin2; 9600 or 115200 bps — stored value
yes — incoming package
Detected during import dyness-full-portfolio-2026-09-02
interfaces.can Review required
yes - COM IN / COM OUT; EXT CANH pin4, CANL pin5; INT CANH pin7, CANL pin8; 500K or 250K — stored value
yes - COM IN / COM OUT — incoming package
Detected during import dyness-full-portfolio-2026-09-02
electrical.max_parallel_units Review required
50 — stored value
CONFLICT - see data_conflicts (user manual 40; official page states 50 but its own expansion range implies 40) — incoming package
Detected during import dyness-full-portfolio-2026-09-02
identity.product_family Review required
Dyness PowerBox series (PowerBox G2 / PowerBox Pro / PowerBox G3) — stored value
Dyness PowerBox (PowerBox G2 / PowerBox Pro / PowerBox G3) — incoming package
Detected during import dyness-full-portfolio-2026-09-02
max_parallel_units Review required
40 — Dyness Powerbox G2 User Manual EN V1, p.22-24, 'supports up to 40 Powerbox G2 in parallel'
50 — energidea.com distributor page (existing record source, 2026-08-31)
distributor page overstates the manufacturer manual limit, or a later firmware raised it; the manual is the better source
max_parallel_units Review required
40 — Dyness Powerbox G2 User Manual EN V1, p.22-24, 'supports up to 40 Powerbox G2 in parallel'
50 — energidea.com distributor page (existing record source, 2026-08-31)
distributor page overstates the manufacturer manual limit, or a later firmware raised it; the manual is the better source
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Charge Rate | 1C |
| Expansion Capacity | 10.24kWh to 409.6kWh (up to 50 parallel units) |
| Integrated Fire Suppression System (shop-rebor.com) | Aerosol-based protection |
| Long-term current guidance | long-term continuous charge and discharge current should be <=1C; recommended max DOD no more than 95% |
| Maximum Output | 10.24 kW |
| Nominal Power / Peak Power | Nominal Power 5.12 kW; Peak Power 10.24 kW |
| Power cable cross-section | 35 mm2 |
| Volume Reduction (marketing copy) | 30% less than previous model |
| Weight Reduction (marketing copy) | 15% less than previous model |
| identity.product_status | active (listed on dyness.com low-voltage residential index as of 2026-09-01) |