Knowledge Base ›
Batteries
Dyness Tower S3 TS7
Verified distributor
global (EN documentation)
verified Sept. 2, 2026
Identity
| category |
batteries
|
| ean |
UNKNOWN
|
| generation |
S3
|
| hardware_revision |
UNKNOWN
|
| legacy_name |
UNKNOWN
|
| manufacturer |
Dyness (Dyness Digital Energy Technology Co., LTD)
|
| market_version |
EN
|
| model |
Tower S3 TS7
|
| mpn |
UNKNOWN
|
| product_family |
Dyness Tower S3 (TS7 / TS10 / TS14 / TS17 / TS21, 192-576 V HV)
|
| product_status |
UNKNOWN
|
| product_status_detail |
current
|
| product_status_evidence |
Live official product page with full specification table at https://dyness.com/towers3-high-voltage-storage-battery-for-household-use (accessed 2026-09-02); official datasheet revision 2025-07-29 and compatibility list revision 2025-12-08 are linked from that page.
|
| region |
global (EN documentation)
|
| release_year |
UNKNOWN
|
| sku |
UNKNOWN
|
| subcategory |
high-voltage residential stacked battery SYSTEM (BDU control unit + N HV9637S modules)
|
| variant_note |
SYSTEM-level record. Tower S3 TS7 = 2 x HV9637S modules on one BDU. Same 37 Ah / 3.552 kWh module electrical class as the older Tower series but a different module part number (HV9637S vs HV9637), slightly lower system weight and a 20 mm taller enclosure per module step. The S3 system voltage range tops out at 108 V per module (216 V), 9 V per module lower than the older Tower's 219 V for the same module count.
|
Electrical
| cell_chemistry |
LiFePO4 (manual: 'LFP' / 'Li-ion (LFP)')
|
| cell_type |
UNKNOWN
|
| continuous_charge_current_a |
18.5
|
| continuous_discharge_current_a |
18.5
|
| continuous_power_kw |
UNKNOWN
|
| cycle_life |
6000
|
| depth_of_discharge_pct |
95
|
| max_charge_current_a |
UNKNOWN
|
| max_charge_power_kw |
4.2
|
| max_discharge_current_a |
37
|
| max_discharge_power_kw |
7.1
|
| max_parallel_units |
12
|
| max_series_units |
6
|
| modules_per_tower_max |
6
|
| modules_per_tower_min |
2
|
| nominal_capacity_ah |
37
|
| nominal_energy_kwh |
7.1
|
| nominal_voltage_v |
192
|
| operating_voltage_max_v |
216
|
| operating_voltage_min_v |
168
|
| parallel_supported |
True
|
| peak_charge_current_a |
22
|
| peak_discharge_current_a |
UNKNOWN
|
| peak_power_kw |
UNKNOWN
|
| round_trip_efficiency_pct |
UNKNOWN
|
| series_supported |
True
|
| system_energy_max_kwh |
255.72
|
| system_energy_min_kwh |
7.1
|
| usable_energy_kwh |
6.745
|
Physical / mechanical
| color |
UNKNOWN
|
| cooling_method |
UNKNOWN
|
| depth_mm |
380
|
| enclosure_material |
UNKNOWN
|
| height_mm |
720
|
| installation_notes |
Official page: '0 wiring, plug&play, allow one people to install'; 'Stackable auto-configuration modules, wireless connection.'
|
| ip_rating |
IP54
|
| mounting_type |
floor-standing stacked tower (BDU control unit + N HV9637S modules on a base)
|
| rack_units |
UNKNOWN
|
| shipping_weight_kg |
UNKNOWN
|
| weight_kg |
103
|
| width_mm |
504
|
Installation
| clearance_notes |
UNKNOWN
|
| indoor_outdoor |
indoor and outdoor (IP54)
|
| notes |
Official page: '0 wiring, plug&play, allow one people to install'. Maximum 12 Tower S3 clusters in parallel.
|
| parallel_hub_required |
No - clusters daisy-chain via the BDU 'Parallel 1#' and 'Parallel 2#' RJ45 ports
|
Environment
| indoor_outdoor |
indoor and outdoor (IP54; official page: 'Indoor & outdoor installations')
|
| max_altitude_m |
UNKNOWN
|
| operating_humidity |
UNKNOWN
|
| operating_temperature_charge_max_c |
50
|
| operating_temperature_charge_min_c |
0
|
| operating_temperature_discharge_max_c |
50
|
| operating_temperature_discharge_min_c |
-10
|
| operating_temperature_max_c |
50
|
| operating_temperature_min_c |
-10
|
| pollution_degree |
II (HV9637S module table)
|
| storage_humidity |
<65% RH
|
| storage_temperature_max_c |
45
|
| storage_temperature_min_c |
5
|
Interfaces & connectors
| bluetooth |
UNKNOWN
|
| can |
True
|
| communication_ports |
Inverter 'CAN/RS485 RJ45' on the BDU (manual Table 2-7 pin definitions); 'Parallel 1#' and 'Parallel 2#' RJ45 for multi-cluster
|
| dry_contact |
UNKNOWN
|
| ethernet |
UNKNOWN
|
| modbus_rtu |
UNKNOWN
|
| modbus_tcp |
UNKNOWN
|
| protocol_notes |
The fetched manual gives inverter CAN/RS485 RJ45 pin definitions (Table 2-7) but no baud rate or protocol identifier.
|
| rs232 |
UNKNOWN
|
| rs485 |
True
|
| usb |
UNKNOWN
|
| wifi |
UNKNOWN
|
Protection
| fire_suppression |
UNKNOWN
|
| notes |
Manual Table 2-1 'Short circuit current [kA]' = 1.5.
|
| overcurrent |
UNKNOWN
|
| short_circuit_current_ka |
1.5
|
Certifications
| emc_certifications |
CE-EMC (7SUN also lists CE-RED)
|
| safety_certifications |
IEC62619 / IEC63056 / IEC62477 / IEC62040
|
| standards |
CE-EMC / CE-RED / IEC62040 / IEC62619 / IEC62477 / IEC63056 / UN38.3
|
| transport_certifications |
UN38.3
|
Warranty & service
| conditions |
UNKNOWN
|
| summary |
10 years per the 7SUN and GVOLT distributor listings for the HV9637S module. No warranty period is printed in the fetched Tower S3 user manual or product page.
|
| years |
10
|
Documents
compatibility_list
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Dyness Tower S3 Series Compatibility List 2025-12-08 - official — located, not retrieved
rev 20251208
datasheet
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Dyness Tower S3 Datasheet EN 2025-07-29 (TowerS3DatasheetEN20250729.pdf) - official, linked from the Tower S3 product page — located, not retrieved
rev 2025-07-29
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Battery system charge current [A] (standard) | 7.4 A |
| Battery system charge voltage (V/DC) | 216 V |
| Battery system discharge current [A] (standard) | 7.4 A |
| Battery system discharge minimum voltage (V/DC) | 168 V |
| Battery system max charge & discharge current [A] | 22.5 A |
| Market experience claim (official page) | 'It has been market-verified for 5 years with 0 accidents.' |
| Max depth of discharge | 100% |
| Operating temperature (module table) | 0~55 C for the HV9637S module vs 0~50 C charge / -10~50 C discharge at system level |
| Optimal operating temperature | 18-30 C |
| Short circuit current [kA] | 1.5 kA |
| Storage SOC | 50 - 55% |
| identity.product_status | current |
| manufacturer_legal_entity_as_printed | Dyness Digital Energy Technology Co., LTD |