ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseBatteries

Dyness Tower T10

Verified distributor global (EN documentation); also sold in the US via dyness.us verified Sept. 2, 2026

Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.

Identity

category batteries
ean UNKNOWN
generation 1.5g
hardware_revision Tower 1.5g (per the user manual title)
legacy_name UNKNOWN
manufacturer Dyness (Dyness Digital Energy Technology Co., LTD)
market_version EN
model Tower T10
mpn UNKNOWN
product_family Dyness Tower (T7 / T10 / T14 / T17 / T21, 192-576 V HV)
product_status UNKNOWN
product_status_detail current
product_status_evidence Live official product page with a full specification table at https://dyness.com/tower-high-voltage-storage-battery-for-household-use (accessed 2026-09-02), and Tower T10 is listed for sale on the official Dyness USA store dyness.us. Counter-evidence: the ONSA Plus retailer blog (30.06.2026) states 'The original Tower (T7-T21) series is being phased out and sold while stocks last.' - recorded as a conflict.
region global (EN documentation); also sold in the US via dyness.us
release_year UNKNOWN
sku UNKNOWN
subcategory high-voltage residential stacked battery SYSTEM (BDU control unit + N battery modules + base)
variant_note SYSTEM-level record. Tower T10 = 3 x HV9637 battery modules on one BDU control module plus a base. The 10.66 kWh / 288 V figures are SYSTEM figures, not module figures (the module is 96 V / 37 Ah / 3.552 kWh - see the separate HV9637 record).

Electrical

cell_chemistry LiFePO4 (manual: 'LFP' / 'Li-ion (LFP)')
cell_type UNKNOWN
continuous_charge_current_a 18.5
continuous_discharge_current_a 18.5
continuous_power_kw 6.39
cycle_life 6000
depth_of_discharge_pct 95
max_charge_current_a 37
max_charge_power_kw 6.39
max_discharge_current_a 37
max_discharge_power_kw 10.66
max_parallel_units 12
max_series_units 6
modules_per_tower_max 6
modules_per_tower_min 2
nominal_capacity_ah 37
nominal_energy_kwh 10.66
nominal_voltage_v 288
operating_voltage_max_v 328
operating_voltage_min_v 252
parallel_supported True
peak_charge_current_a UNKNOWN
peak_discharge_current_a UNKNOWN
peak_power_kw UNKNOWN
round_trip_efficiency_pct UNKNOWN
series_supported True
system_energy_max_kwh 255.72
system_energy_min_kwh 7.1
usable_energy_kwh 10.127

Physical / mechanical

color White
cooling_method UNKNOWN
depth_mm 380
enclosure_material UNKNOWN
height_mm 900
installation_notes Tower Pro/Tower user manual clearance guidance: 300 mm minimum clearance around the enclosure. Total weight includes the BDU control module and the base, which are counted separately from the battery modules.
ip_rating IP54
mounting_type floor-standing stacked tower (BDU control module on top of N stacked battery modules, on a base)
rack_units UNKNOWN
shipping_weight_kg UNKNOWN
weight_kg 146
width_mm 504

Installation

clearance_notes 300 mm minimum clearance is shown in the Dyness tower installation clearance diagrams
indoor_outdoor indoor and outdoor (IP54)
notes The BDU control module and the base are mandatory, are ordered separately from the battery modules, and their mass is included in the quoted tower net weight. Modules are stackable with auto-configuration / wireless connection per the official product page.
parallel_hub_required UNKNOWN

Environment

indoor_outdoor indoor and outdoor (IP54)
max_altitude_m UNKNOWN
operating_humidity UNKNOWN
operating_temperature_charge_max_c 50
operating_temperature_charge_min_c 0
operating_temperature_discharge_max_c 50
operating_temperature_discharge_min_c -10
operating_temperature_max_c 50
operating_temperature_min_c -10
pollution_degree II (battery module table)
storage_humidity <65% RH
storage_temperature_max_c 45
storage_temperature_min_c 5

Interfaces & connectors

bluetooth UNKNOWN
can True
communication_ports BDU 'EXT-CAN/RS485' RJ45 to inverter; composite 9-pin connectors between BDU and battery modules; parallel ports for multi-cluster
dry_contact UNKNOWN
ethernet UNKNOWN
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
protocol_notes EXT-CAN/RS485 pinout: PIN1 Orange/White 485_A, PIN2 Orange 485_B, PIN3 Green/White Reserved, PIN4 Blue CANH, PIN5 Blue/White CANL, PIN6 Green CANIN, PIN7 Brown/White CANOUT, PIN8 Brown NC
rs232 Datasheet 'Communication' row reads 'CAN/RS485/RS232'; the user manual documents only CAN/RS485 pins on the BDU EXT port
rs485 True
usb UNKNOWN
wifi UNKNOWN

Protection

fire_suppression UNKNOWN
notes Manual Table 2-1 'Short circuit current [kA]' = 1.5. Manual protection chapter also requires a 30-minute wait before resetting a tripped DC breaker.
overcurrent Datasheet 'Protection Features': Overcharge/Overdischarge/Overcurrent/Overtemperature/Short Circuit
short_circuit_current_ka 1.5

Certifications

emc_certifications CE-EMC
safety_certifications IEC62619 / IEC63056 / IEC62477 / IEC62040 / IEC60730 / VDE2510-50 / UL1973 / UKCA / CEC Accredited
standards UN38.3/CE-EMC/IEC62040/IEC62619/IEC62477/IEC60730/IEC63056/UKCA/CEC Accredited/UL1973/VDE2510-50
transport_certifications UN38.3

Warranty & service

conditions UNKNOWN
summary No warranty period is printed in the fetched Tower datasheet, user manual or product page for this model. The 7SUN listing for the Tower BDU control module quotes a 10-year warranty.
years UNKNOWN

Documents

compatibility_list List of the Inverter Brands Compatible with Dyness Tower Series, last updated 06/05/2025 - distributor mirror on vanmeenen.com rev 250506
datasheet {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Dyness Tower datasheet EN 2025-04-22 (TowerDatasheetEN20250422-281.pdf) - official, linked from the Tower product page — located, not retrieved rev 2025-04-22
datasheet Dyness Tower datasheet-EN V1.0-20230704 - distributor mirror on estsolar.lt rev V1.0-20230704
distributor_listing 7SUN distributor listing: Control module - DYNESS - BDU - ES-BC-EU rev UNKNOWN
product_page Dyness Tower T14 product page on dyness.us (official Dyness USA store) rev UNKNOWN
product_page Dyness Tower official product page (HTML, dyness.com without www) rev UNKNOWN
retailer_article ONSA Plus retailer blog: 'The Dyness Tower is ending: move to Tower Pro and Stack' (published 30.06.2026) rev UNKNOWN
user_manual Tower USER MANUAL HV Battery System Tower - T7/T10/T14/T17/T21 192-576V (Tower 1.5g User Manual-EN) - distributor mirror on cdn.prod.website-files.com rev Tower 1.5g / V1

Recorded conflicts

electrical.nominal_energy_kwh / electrical.usable_energy_kwh (label semantics) Review required
10.66 kWh labelled 'Total energy stored' with a separate 'Usable energy' of 10.127 kWh — Tower 1.5g User Manual EN, Table 2-1
10.66 kWh labelled 'Usable Energy' — Dyness Tower datasheet-EN V1.0-20230704 (distributor mirror: estsolar.lt)
identity.product_status Review required
current - a live official product page with a full spec table exists on dyness.com — Dyness Tower official product page
being phased out - 'The original Tower (T7-T21) series is being phased out and sold while stocks last.' — ONSA Plus retailer blog, 'The Dyness Tower is ending: move to Tower Pro and Stack' (30.06.2026)
electrical.max_parallel_units Review required
12 — Dyness Tower official product page (dyness.com), technical specification table 'Expansion' row and feature text 'Up to 12 clusters in parallel, 7.1kWh~255.72kWh capacity'
4 — Dyness Tower datasheet-EN V1.0-20230704, 'Parallel Expansion' row: 'Max. 4 towers can be connected in parallel' (distributor mirror: estsolar.lt)

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Battery system charge current [A] (standard)7.4 A
Battery system charge voltage (V/DC)328.5 V
Battery system discharge current [A] (standard)7.4 A
Battery system discharge minimum voltage (V/DC)252 V
Battery system max charge & discharge current [A] (in communication with inverter)22.5 A
Colour (official product page)White
Longest storage duration without charge/discharge (user manual)should not exceed 6 months; activation every three months advised
Market experience claim (official product page)'It has been market-verified for 5 years with 0 accidents.'
Max depth of discharge100%
Module configuration3 series
Pre-storage SOC (user manual storage chapter)50 - 55%
Short circuit current [kA]1.5 kA
documented_relationship:battery_inverter{"to_manufacturer": "Afore", "to_model": "AF3K~9.6K-DH, AF3K~30K-TH", "relationship_type": "battery_inverter", "match_level": "series", "communication_protocol": "CAN/RS485 (Tower BDU EXT-CAN/RS485 RJ45 port)", "required_settings": "UNKNOWN - the compatibility list carries no protocol/DIP/firmware column, and the Tower user manual only says to select the correct battery type in the inverter settings", "source": "List of the Inverter Brands Compatible with Dyness Tower Series, last updated 06/05/2025 (distributor mirror: vanmeenen.com)", "source_url": "https://www.vanmeenen.com/wp-content/uploads/2025/05/Dyness-Tower-series-campatible-list-250506.pdf", "source_page": "compatibility table", "confidence": "distributor-verified", "notes": "The document's Tower columns are headed T-7 / T-10 / T-14 / T-17 / T-21 and every listed brand is check-marked across all five columns, so the approval is
identity.product_statuscurrent
manufacturer_legal_entity_as_printedDyness Digital Energy Technology Co., LTD

Build a system with this product