FoxESS H3-10.0-Smart
Official manufacturer global (EN datasheet) verified Aug. 31, 2026
Hybrid Inverter category listing / H3 Smart product page image, visually verified
Identity
| brand | FoxESS |
| category | inverters |
| ean | UNKNOWN |
| generation | Smart |
| manufacturer | FoxESS |
| market_version | UNKNOWN |
| model | H3-10.0-Smart |
| mpn | UNKNOWN |
| product_family | H3 Smart three-phase hybrid series (documented together with AC3 / P3S in the shared manual) |
| product_revision | UNKNOWN |
| product_status | active |
| region | global (EN datasheet) |
| release_year | UNKNOWN |
| sku | UNKNOWN |
Electrical
| ac_coupling_support | UNKNOWN |
| backup_eps_output_support | True |
| battery_support | True |
| battery_type | Lithium-Ion |
| battery_voltage_class | HV |
| battery_voltage_max_v | 800 |
| battery_voltage_min_v | 100 |
| communication_can | True |
| communication_ethernet | True |
| communication_rs485 | True |
| communication_wifi | True |
| ct_support | UNKNOWN |
| generator_input_support | UNKNOWN |
| grid_certifications | UNKNOWN |
| grid_export_control | UNKNOWN |
| home_assistant_integration | UNKNOWN |
| max_ac_power_kw | 11 |
| max_battery_charge_current_a | UNKNOWN (extracted value of 15,000A is almost certainly an OCR/table-parsing error; excluded) |
| max_battery_charge_power_kw | UNKNOWN |
| max_battery_discharge_current_a | UNKNOWN (same issue) |
| max_dc_voltage_v | 1000 |
| max_input_current_per_mppt_a | 15.2 |
| max_pv_input_power_w | 20000 |
| max_short_circuit_current_per_mppt_a | 16.7 |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| mppt_max_voltage_v | 950 |
| mppt_min_voltage_v | 120 |
| num_mppt | 3 |
| officially_supported_battery_brands | UNKNOWN |
| phase_type | three-phase |
| pv_inputs_per_mppt | 1 |
| rated_ac_power_kw | 10 |
| smart_meter_support | True |
| startup_voltage_v | 140 |
| sunspec_support | UNKNOWN |
| topology | hybrid |
Physical / mechanical
| bracket_dimensions_mm | UNKNOWN |
| cable_entry_positions | bottom of the unit: A DC switch, B PV1, C PV2, D PV3 (H3-Smart only), E BAT, F BMS (CAN), G LAN, H DRM, I Meter (RS485), J COMM/DONGLE (WiFi/4G), K Antenna, L COM (EMS485, relays, E-stop), M EPS/GRID, N grounding screw |
| cable_gland_sizes |
diameter 18 mm gland (cable OD 17.5-18.5 mm); diameter 21 mm gland (cable OD 19-21 mm); diameter 6 mm ground gland (cable 5-6 mm) - manual p.40
H3 Smart / P3S Series User Manual V1.3 — manual p.40 cable gland table
|
| depth_mm | 226 |
| enclosure_material | UNKNOWN |
| height_mm | 450 |
| housing_color | UNKNOWN |
| mounting_bolt_size | M5 screw and washer to secure the inverter to the bracket (manual p.30); 6x expansion tubes + 6x expansion screws supplied (p.22) |
| mounting_hole_diameter_mm | 8 (drilled hole diameter, manual p.29) |
| mounting_hole_spacing_mm | UNKNOWN (manual p.28 instructs marking 2 holes from the supplied bracket; centre-to-centre spacing not printed) |
| mounting_plate_dimensions_mm | UNKNOWN |
| mounting_type | ['wall'] |
| screw_sizes | M5 (bracket securing screw) |
| shipping_weight_kg | 40 |
| terminal_locations | all connections on the bottom face |
| torque_specs | 2.5 +/- 0.1 N.m (hex-wrench terminal fastening, manual pp.40-41) |
| weight_kg | 34 (datasheet V1.9/V2.0 net weight; user manual p.20 states 33.5 kg for the 5-10 kW models - see data_conflicts) |
| width_mm |
600
H3 Smart Datasheet V2.0 — 'Dimensions (W*H*D) 600*450*226 mm'; user manual p.20 identical
|
Installation
| altitude_derating_note | '<4000 @Derating exceeding 2000 m' (datasheet V2.0 and manual p.20) |
| clearance_bottom_mm | 300 |
| clearance_front_mm | UNKNOWN |
| clearance_left_mm | 100 |
| clearance_right_mm | 100 |
| clearance_top_mm |
300
H3 Smart / P3S Series User Manual V1.3 — manual p.26 clearance table: Left 100, Right 100, Top 300, Bottom 300 mm
|
| cooling_airflow_requirements | natural convection - keep the stated clearances free |
| direct_sunlight_restriction | not in direct sunlight; not in areas where highly flammable materials are stored |
| drill_hole_depth_mm | 50 |
| drill_hole_diameter_mm | 8 |
| indoor_outdoor | outdoor rated (IP65); manual permits indoor or outdoor within the stated environmental limits |
| installation_humidity_range | not in an environment of precipitation or humidity above 95%; do not open the cabinet door when air humidity exceeds 95% |
| installation_temperature_range_c | UNKNOWN |
| max_installation_altitude_m | 4000 (derating above 2000 m) |
| minimum_wall_thickness_mm | UNKNOWN |
| mounting_orientation | vertical wall mount, level; wall slope within +5 degrees |
| orientation_allowed | ['vertical wall (level)'] |
| orientation_forbidden |
['forward tilt', 'horizontal', 'upside down', 'backward tilt', 'sideways tilt']
H3 Smart / P3S Series User Manual V1.3 — manual p.28: 'Do not tilt the energy storage forward, horizontally, upside down, backward and sideways'
|
| surface_requirements | solid brick/concrete or mounting surface of equivalent strength; must be supported or strengthened if the wall strength is insufficient (e.g. wooden wall); flat, dry and free of standing water |
| two_person_lift_required | UNKNOWN |
| ventilation_requirements | install under good ventilation conditions |
Environment
| cooling_method | natural convection |
| corrosion_class | UNKNOWN |
| fan_replaceable | N/A (natural cooling) |
| ik_rating | UNKNOWN |
| ip_rating | IP65 (For outdoor use) |
| max_altitude_m |
4000 (derating exceeding 2000)
H3 Smart Datasheet V2.0 — 'Altitude <4000 @Derating exceeding 2000 m'
|
| nema_rating | UNKNOWN |
| noise_level_db | <40 dB |
| operating_temperature_c | -25 ~ +60 (Derating at 45) |
| pollution_degree | UNKNOWN |
| relative_humidity | 0 ~ 100 % |
| salt_mist_resistance | UNKNOWN |
| storage_temperature_c | -40 ~ +70 |
| uv_resistance | UNKNOWN |
Interfaces & connectors
| ac_terminal_type | supplied AC connector x1 |
| backup_eps_terminal | EPS/GRID port (position M) |
| battery_terminal_type | supplied battery connectors (1x positive, 1x negative) with pin contacts |
| bluetooth | yes (WiLAN) |
| can | yes - BMS(CAN) |
| cellular | optional 4G dongle |
| cloud_api | UNKNOWN |
| drm | yes |
| dry_contacts | E-stop input on the COM connector |
| ethernet | yes (LAN port; WiLAN module combines WiFi+LAN+Bluetooth) |
| local_api | UNKNOWN |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| mqtt | UNKNOWN |
| ocpp | UNKNOWN |
| protocol_notes | Datasheet communication row verbatim: 'Ethernet, EMS(RS485), Meter, WiLAN(Wifi+LAN+Bluetooth), 4G(Optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready' |
| pv_connector_type | MC-style PV connectors supplied (3x positive, 3x negative connectors plus pin contacts, manual p.22); brand not named in the fetched documents |
| relay_outputs | relays on the COM connector (manual port list 'COM (EMS485, Relays, Estop)'); count and rating not stated |
| ripple_control | yes |
| rs232 | UNKNOWN |
| rs485 | yes - EMS(RS485) and Meter(RS485) |
| sg_ready | yes |
| sunspec | UNKNOWN |
| usb | yes (USB 2.0, <32 GB storage devices, manual p.84) |
| wifi | yes (WiLAN) |
| zigbee | UNKNOWN |
Controls & display
| audible_alarm | UNKNOWN |
| buttons | Up, Down, OK, Return function keys (manual p.88) |
| display_type | datasheet: 'Capacitive touch sensor *4'; shared H3/AC3/P3 manual p.88 describes an LCD screen |
| leds | Red (fault), Blue (network), Green (normal) |
| local_display | True |
| mobile_app | UNKNOWN (FoxCloud ecosystem; not named in the fetched pages) |
| remote_display_option | UNKNOWN |
| status_indicators | UNKNOWN |
| touchscreen | capacitive touch keys (4) |
| web_interface | UNKNOWN |
Protection
| afci | Optional |
| anti_islanding |
yes - 'Active Frequency Drift with Positive Feedback'
H3 Smart Datasheet V1.9 — row 'Anti-Islanding: Active Frequency Drift with Positive Feedback'
|
| ground_fault_protection | yes (earth-fault detection) |
| insulation_monitoring | yes (insulation detection) |
| integrated_breakers_fuses | UNKNOWN |
| integrated_dc_switch | True |
| over_current | UNKNOWN |
| over_temperature | UNKNOWN |
| over_voltage | UNKNOWN |
| overvoltage_category | III (AC side), II (DC side) |
| protection_class | I |
| residual_current_monitoring | yes (datasheet V2.0: '1 inside for EPS & Earth fault') |
| reverse_polarity | UNKNOWN |
| short_circuit | UNKNOWN |
| surge_protection | Type II (PV) / Type II (AC) |
| under_voltage | UNKNOWN |
Warranty & service
| conditions | UNKNOWN |
| cycle_life | N/A |
| design_life_years | UNKNOWN |
| extended_options_years | UNKNOWN |
| fan_replaceable | N/A (natural cooling) |
| field_replaceable_parts | UNKNOWN |
| fuse_replaceable | UNKNOWN |
| service_intervals | UNKNOWN |
| standard_years |
10
H3 Smart Datasheet V1.9 — row 'Standard Warranty [year] 10'
|
Documents
Documented compatibility
Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.
inverter_battery
FoxESS ECS4100 (EC4100 Master/Slave module)
COMPATIBLEcommunity-verified
FoxESS Inverter Compatibility Statement (naming conflict - see Data Quality Report)
inverter_evse
go-e GmbH go-eCharger Gemini (11kW and 22kW variants)
COMPATIBLEinferred-from-electrical-parameters
go-e Gemini Datasheet (open local API/Modbus TCP/MQTT) + third-party EMS tools (evcc, openWB)
Recorded conflicts
eps_max_apparent_power_va Review required
11000 — datasheet V1.9 EPS section
12000 — datasheet V2.0 EPS section
datasheet revision V1.9 -> V2.0 raised the EPS rating
physical.weight_kg Review required
34 — datasheet V1.9 and V2.0, 'Net Weight 34 kg'
33.5 — H3 Smart/P3S user manual V1.3 p.20, 'Net Weight (5-10KW) 33.5 kg'
document revision or the manual quoting the lightest model in the range
max_pv_input_power_w Review required
20000 — value currently stored on the record
10000 per MPPT ('Max PV Power 10000/10000/10000 W', 3 MPPTs) — official datasheet V2.0
10000 ('Max. DC Input Power [W] 10000') — official datasheet V1.9
per-MPPT vs total array figure; 3 x 10000 W per MPPT is consistent with a 20 kWp array limit but the datasheets' own 'Max. DC Input Power' row reads 10000
startup_voltage_v Review required
140 — value currently stored on the record
90 — official datasheet V1.9, verbatim row 'Start-up Input Voltage [V] 90'
document revision or earlier extraction error
max_short_circuit_current_per_mppt_a Review required
16.7 — value currently stored on the record (equals the V2.0 'Max AC Current per Phase 16.7 A' row)
25/25/25 (per MPPT) — official datasheet V1.9, verbatim row 'Max. MPPT Short Circuit Current [A] 25/25/25'
20/20/20 (per MPPT) — official datasheet V2.0 extraction 'Max Isc per MPPT 20/20/20 A'
stored value is an AC row; the two datasheet revisions themselves disagree (V1.9 25 A vs V2.0 20 A) - possible hardware revision or extraction error. Safety-relevant.
max_input_current_per_mppt_a Review required
15.2 — value currently stored on the record
20/20/20 (per MPPT) — official H3 Smart datasheet V1.9, verbatim row 'Max. MPPT Input Current [A] 20/20/20'
the stored 15.2 A is identical to the datasheet AC row 'Max AC Current 15.2 A per phase' (V1.9) / 'Rated AC Current per Phase 15.2 A' (V2.0) - almost certainly an AC value assigned to the DC row in an earlier pass
eps_max_apparent_power_va Review required
11000 — datasheet V1.9 EPS section
12000 — datasheet V2.0 EPS section
datasheet revision V1.9 -> V2.0 raised the EPS rating
physical.weight_kg Review required
34 — datasheet V1.9 and V2.0, 'Net Weight 34 kg'
33.5 — H3 Smart/P3S user manual V1.3 p.20, 'Net Weight (5-10KW) 33.5 kg'
document revision or the manual quoting the lightest model in the range
max_pv_input_power_w Review required
20000 — value currently stored on the record
10000 per MPPT ('Max PV Power 10000/10000/10000 W', 3 MPPTs) — official datasheet V2.0
10000 ('Max. DC Input Power [W] 10000') — official datasheet V1.9
per-MPPT vs total array figure; 3 x 10000 W per MPPT is consistent with a 20 kWp array limit but the datasheets' own 'Max. DC Input Power' row reads 10000
startup_voltage_v Review required
140 — value currently stored on the record
90 — official datasheet V1.9, verbatim row 'Start-up Input Voltage [V] 90'
document revision or earlier extraction error
max_short_circuit_current_per_mppt_a Review required
16.7 — value currently stored on the record (equals the V2.0 'Max AC Current per Phase 16.7 A' row)
25/25/25 (per MPPT) — official datasheet V1.9, verbatim row 'Max. MPPT Short Circuit Current [A] 25/25/25'
20/20/20 (per MPPT) — official datasheet V2.0 extraction 'Max Isc per MPPT 20/20/20 A'
stored value is an AC row; the two datasheet revisions themselves disagree (V1.9 25 A vs V2.0 20 A) - possible hardware revision or extraction error. Safety-relevant.
max_input_current_per_mppt_a Review required
15.2 — value currently stored on the record
20/20/20 (per MPPT) — official H3 Smart datasheet V1.9, verbatim row 'Max. MPPT Input Current [A] 20/20/20'
the stored 15.2 A is identical to the datasheet AC row 'Max AC Current 15.2 A per phase' (V1.9) / 'Rated AC Current per Phase 15.2 A' (V2.0) - almost certainly an AC value assigned to the DC row in an earlier pass
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| EPS switch-over / EPS ratings (V2.0) | EPS max apparent power 12000 VA, max EPS current per phase 18.2 A |
| Min. Battery Voltage @Full AC Load | 50.0 V |
| Nominal DC Operating Voltage | 620 V |
| Strings per MPP Tracker | 1+1+1 |
| USB storage limit | USB 2.0 only, <32 GB |