ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseInverters

FoxESS H3-10.0-Smart

Official manufacturer global (EN datasheet) verified Aug. 31, 2026

Identity

brand FoxESS
category inverters
ean UNKNOWN
generation Smart
manufacturer FoxESS
market_version UNKNOWN
model H3-10.0-Smart
mpn UNKNOWN
product_family H3 Smart three-phase hybrid series (documented together with AC3 / P3S in the shared manual)
product_revision UNKNOWN
product_status active
region global (EN datasheet)
release_year UNKNOWN
sku UNKNOWN

Electrical

ac_coupling_support UNKNOWN
backup_eps_output_support True
battery_support True
battery_type Lithium-Ion
battery_voltage_class HV
battery_voltage_max_v 800
battery_voltage_min_v 100
communication_can True
communication_ethernet True
communication_rs485 True
communication_wifi True
ct_support UNKNOWN
generator_input_support UNKNOWN
grid_certifications UNKNOWN
grid_export_control UNKNOWN
home_assistant_integration UNKNOWN
max_ac_power_kw 11
max_battery_charge_current_a UNKNOWN (extracted value of 15,000A is almost certainly an OCR/table-parsing error; excluded)
max_battery_charge_power_kw UNKNOWN
max_battery_discharge_current_a UNKNOWN (same issue)
max_dc_voltage_v 1000
max_input_current_per_mppt_a 15.2
max_pv_input_power_w 20000
max_short_circuit_current_per_mppt_a 16.7
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
mppt_max_voltage_v 950
mppt_min_voltage_v 120
num_mppt 3
officially_supported_battery_brands UNKNOWN
phase_type three-phase
pv_inputs_per_mppt 1
rated_ac_power_kw 10
smart_meter_support True
startup_voltage_v 140
sunspec_support UNKNOWN
topology hybrid

Physical / mechanical

bracket_dimensions_mm UNKNOWN
cable_entry_positions bottom of the unit: A DC switch, B PV1, C PV2, D PV3 (H3-Smart only), E BAT, F BMS (CAN), G LAN, H DRM, I Meter (RS485), J COMM/DONGLE (WiFi/4G), K Antenna, L COM (EMS485, relays, E-stop), M EPS/GRID, N grounding screw
cable_gland_sizes diameter 18 mm gland (cable OD 17.5-18.5 mm); diameter 21 mm gland (cable OD 19-21 mm); diameter 6 mm ground gland (cable 5-6 mm) - manual p.40
H3 Smart / P3S Series User Manual V1.3 — manual p.40 cable gland table
depth_mm 226
enclosure_material UNKNOWN
height_mm 450
housing_color UNKNOWN
mounting_bolt_size M5 screw and washer to secure the inverter to the bracket (manual p.30); 6x expansion tubes + 6x expansion screws supplied (p.22)
mounting_hole_diameter_mm 8 (drilled hole diameter, manual p.29)
mounting_hole_spacing_mm UNKNOWN (manual p.28 instructs marking 2 holes from the supplied bracket; centre-to-centre spacing not printed)
mounting_plate_dimensions_mm UNKNOWN
mounting_type ['wall']
screw_sizes M5 (bracket securing screw)
shipping_weight_kg 40
terminal_locations all connections on the bottom face
torque_specs 2.5 +/- 0.1 N.m (hex-wrench terminal fastening, manual pp.40-41)
weight_kg 34 (datasheet V1.9/V2.0 net weight; user manual p.20 states 33.5 kg for the 5-10 kW models - see data_conflicts)
width_mm 600
H3 Smart Datasheet V2.0 — 'Dimensions (W*H*D) 600*450*226 mm'; user manual p.20 identical

Installation

altitude_derating_note '<4000 @Derating exceeding 2000 m' (datasheet V2.0 and manual p.20)
clearance_bottom_mm 300
clearance_front_mm UNKNOWN
clearance_left_mm 100
clearance_right_mm 100
clearance_top_mm 300
H3 Smart / P3S Series User Manual V1.3 — manual p.26 clearance table: Left 100, Right 100, Top 300, Bottom 300 mm
cooling_airflow_requirements natural convection - keep the stated clearances free
direct_sunlight_restriction not in direct sunlight; not in areas where highly flammable materials are stored
drill_hole_depth_mm 50
drill_hole_diameter_mm 8
indoor_outdoor outdoor rated (IP65); manual permits indoor or outdoor within the stated environmental limits
installation_humidity_range not in an environment of precipitation or humidity above 95%; do not open the cabinet door when air humidity exceeds 95%
installation_temperature_range_c UNKNOWN
max_installation_altitude_m 4000 (derating above 2000 m)
minimum_wall_thickness_mm UNKNOWN
mounting_orientation vertical wall mount, level; wall slope within +5 degrees
orientation_allowed ['vertical wall (level)']
orientation_forbidden ['forward tilt', 'horizontal', 'upside down', 'backward tilt', 'sideways tilt']
H3 Smart / P3S Series User Manual V1.3 — manual p.28: 'Do not tilt the energy storage forward, horizontally, upside down, backward and sideways'
surface_requirements solid brick/concrete or mounting surface of equivalent strength; must be supported or strengthened if the wall strength is insufficient (e.g. wooden wall); flat, dry and free of standing water
two_person_lift_required UNKNOWN
ventilation_requirements install under good ventilation conditions

Environment

cooling_method natural convection
corrosion_class UNKNOWN
fan_replaceable N/A (natural cooling)
ik_rating UNKNOWN
ip_rating IP65 (For outdoor use)
max_altitude_m 4000 (derating exceeding 2000)
H3 Smart Datasheet V2.0 — 'Altitude <4000 @Derating exceeding 2000 m'
nema_rating UNKNOWN
noise_level_db <40 dB
operating_temperature_c -25 ~ +60 (Derating at 45)
pollution_degree UNKNOWN
relative_humidity 0 ~ 100 %
salt_mist_resistance UNKNOWN
storage_temperature_c -40 ~ +70
uv_resistance UNKNOWN

Interfaces & connectors

ac_terminal_type supplied AC connector x1
backup_eps_terminal EPS/GRID port (position M)
battery_terminal_type supplied battery connectors (1x positive, 1x negative) with pin contacts
bluetooth yes (WiLAN)
can yes - BMS(CAN)
cellular optional 4G dongle
cloud_api UNKNOWN
drm yes
dry_contacts E-stop input on the COM connector
ethernet yes (LAN port; WiLAN module combines WiFi+LAN+Bluetooth)
local_api UNKNOWN
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
mqtt UNKNOWN
ocpp UNKNOWN
protocol_notes Datasheet communication row verbatim: 'Ethernet, EMS(RS485), Meter, WiLAN(Wifi+LAN+Bluetooth), 4G(Optional), DRM, Ripple Control, USB, BMS(CAN), SG Ready'
pv_connector_type MC-style PV connectors supplied (3x positive, 3x negative connectors plus pin contacts, manual p.22); brand not named in the fetched documents
relay_outputs relays on the COM connector (manual port list 'COM (EMS485, Relays, Estop)'); count and rating not stated
ripple_control yes
rs232 UNKNOWN
rs485 yes - EMS(RS485) and Meter(RS485)
sg_ready yes
sunspec UNKNOWN
usb yes (USB 2.0, <32 GB storage devices, manual p.84)
wifi yes (WiLAN)
zigbee UNKNOWN

Controls & display

audible_alarm UNKNOWN
buttons Up, Down, OK, Return function keys (manual p.88)
display_type datasheet: 'Capacitive touch sensor *4'; shared H3/AC3/P3 manual p.88 describes an LCD screen
leds Red (fault), Blue (network), Green (normal)
local_display True
mobile_app UNKNOWN (FoxCloud ecosystem; not named in the fetched pages)
remote_display_option UNKNOWN
status_indicators UNKNOWN
touchscreen capacitive touch keys (4)
web_interface UNKNOWN

Protection

afci Optional
anti_islanding yes - 'Active Frequency Drift with Positive Feedback'
H3 Smart Datasheet V1.9 — row 'Anti-Islanding: Active Frequency Drift with Positive Feedback'
ground_fault_protection yes (earth-fault detection)
insulation_monitoring yes (insulation detection)
integrated_breakers_fuses UNKNOWN
integrated_dc_switch True
over_current UNKNOWN
over_temperature UNKNOWN
over_voltage UNKNOWN
overvoltage_category III (AC side), II (DC side)
protection_class I
residual_current_monitoring yes (datasheet V2.0: '1 inside for EPS & Earth fault')
reverse_polarity UNKNOWN
short_circuit UNKNOWN
surge_protection Type II (PV) / Type II (AC)
under_voltage UNKNOWN

Warranty & service

conditions UNKNOWN
cycle_life N/A
design_life_years UNKNOWN
extended_options_years UNKNOWN
fan_replaceable N/A (natural cooling)
field_replaceable_parts UNKNOWN
fuse_replaceable UNKNOWN
service_intervals UNKNOWN
standard_years 10
H3 Smart Datasheet V1.9 — row 'Standard Warranty [year] 10'

Documents

datasheet H3 Smart Datasheet V1.9 rev V1.9
datasheet H3 Smart Datasheet V2.0 rev V2.0
product-page H3 Smart product page rev UNKNOWN
user-manual H3 Smart / P3S Series User Manual V1.3 rev V1.3

Documented compatibility

Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.

inverter_battery

FoxESS ECS4100 (EC4100 Master/Slave module) COMPATIBLEcommunity-verified
FoxESS Inverter Compatibility Statement (naming conflict - see Data Quality Report)

inverter_evse

go-e GmbH go-eCharger Gemini (11kW and 22kW variants) COMPATIBLEinferred-from-electrical-parameters
go-e Gemini Datasheet (open local API/Modbus TCP/MQTT) + third-party EMS tools (evcc, openWB)

Recorded conflicts

eps_max_apparent_power_va Review required
11000 — datasheet V1.9 EPS section
12000 — datasheet V2.0 EPS section
datasheet revision V1.9 -> V2.0 raised the EPS rating
physical.weight_kg Review required
34 — datasheet V1.9 and V2.0, 'Net Weight 34 kg'
33.5 — H3 Smart/P3S user manual V1.3 p.20, 'Net Weight (5-10KW) 33.5 kg'
document revision or the manual quoting the lightest model in the range
max_pv_input_power_w Review required
20000 — value currently stored on the record
10000 per MPPT ('Max PV Power 10000/10000/10000 W', 3 MPPTs) — official datasheet V2.0
10000 ('Max. DC Input Power [W] 10000') — official datasheet V1.9
per-MPPT vs total array figure; 3 x 10000 W per MPPT is consistent with a 20 kWp array limit but the datasheets' own 'Max. DC Input Power' row reads 10000
startup_voltage_v Review required
140 — value currently stored on the record
90 — official datasheet V1.9, verbatim row 'Start-up Input Voltage [V] 90'
document revision or earlier extraction error
max_short_circuit_current_per_mppt_a Review required
16.7 — value currently stored on the record (equals the V2.0 'Max AC Current per Phase 16.7 A' row)
25/25/25 (per MPPT) — official datasheet V1.9, verbatim row 'Max. MPPT Short Circuit Current [A] 25/25/25'
20/20/20 (per MPPT) — official datasheet V2.0 extraction 'Max Isc per MPPT 20/20/20 A'
stored value is an AC row; the two datasheet revisions themselves disagree (V1.9 25 A vs V2.0 20 A) - possible hardware revision or extraction error. Safety-relevant.
max_input_current_per_mppt_a Review required
15.2 — value currently stored on the record
20/20/20 (per MPPT) — official H3 Smart datasheet V1.9, verbatim row 'Max. MPPT Input Current [A] 20/20/20'
the stored 15.2 A is identical to the datasheet AC row 'Max AC Current 15.2 A per phase' (V1.9) / 'Rated AC Current per Phase 15.2 A' (V2.0) - almost certainly an AC value assigned to the DC row in an earlier pass
eps_max_apparent_power_va Review required
11000 — datasheet V1.9 EPS section
12000 — datasheet V2.0 EPS section
datasheet revision V1.9 -> V2.0 raised the EPS rating
physical.weight_kg Review required
34 — datasheet V1.9 and V2.0, 'Net Weight 34 kg'
33.5 — H3 Smart/P3S user manual V1.3 p.20, 'Net Weight (5-10KW) 33.5 kg'
document revision or the manual quoting the lightest model in the range
max_pv_input_power_w Review required
20000 — value currently stored on the record
10000 per MPPT ('Max PV Power 10000/10000/10000 W', 3 MPPTs) — official datasheet V2.0
10000 ('Max. DC Input Power [W] 10000') — official datasheet V1.9
per-MPPT vs total array figure; 3 x 10000 W per MPPT is consistent with a 20 kWp array limit but the datasheets' own 'Max. DC Input Power' row reads 10000
startup_voltage_v Review required
140 — value currently stored on the record
90 — official datasheet V1.9, verbatim row 'Start-up Input Voltage [V] 90'
document revision or earlier extraction error
max_short_circuit_current_per_mppt_a Review required
16.7 — value currently stored on the record (equals the V2.0 'Max AC Current per Phase 16.7 A' row)
25/25/25 (per MPPT) — official datasheet V1.9, verbatim row 'Max. MPPT Short Circuit Current [A] 25/25/25'
20/20/20 (per MPPT) — official datasheet V2.0 extraction 'Max Isc per MPPT 20/20/20 A'
stored value is an AC row; the two datasheet revisions themselves disagree (V1.9 25 A vs V2.0 20 A) - possible hardware revision or extraction error. Safety-relevant.
max_input_current_per_mppt_a Review required
15.2 — value currently stored on the record
20/20/20 (per MPPT) — official H3 Smart datasheet V1.9, verbatim row 'Max. MPPT Input Current [A] 20/20/20'
the stored 15.2 A is identical to the datasheet AC row 'Max AC Current 15.2 A per phase' (V1.9) / 'Rated AC Current per Phase 15.2 A' (V2.0) - almost certainly an AC value assigned to the DC row in an earlier pass

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

EPS switch-over / EPS ratings (V2.0)EPS max apparent power 12000 VA, max EPS current per phase 18.2 A
Min. Battery Voltage @Full AC Load50.0 V
Nominal DC Operating Voltage620 V
Strings per MPP Tracker1+1+1
USB storage limitUSB 2.0 only, <32 GB

Build a system with this product