Growatt MOD 10KTL3-XH
Manufacturer documented EU/global verified Sept. 2, 2026
primary product image served on the official MOD 3000-10000TL3-XH product page; the image file's alt text is 'MOD 3000~9000TL3-X.png', i.e. Growatt reuses one MOD-family enclosure render across the X and XH pages
Identity
| brand | Growatt |
| category | inverters |
| ean | UNKNOWN |
| generation | XH |
| manufacturer | Growatt (Shenzhen Growatt New Energy Technology Co., Ltd.) |
| model | MOD 10KTL3-XH |
| mpn | UNKNOWN |
| product_family | MOD 3-10KTL3-XH (MOD 3000-10000TL3-XH); MOD 3000-10000TL3-XH(BP) is the backup-capable sibling |
| product_status | active |
| region | EU/global |
| sku | UNKNOWN |
Electrical
| ac_coupling_support | UNKNOWN |
| backup_eps_output_support | UNKNOWN for standard XH (manual documents backup for BP series with APX HV battery) |
| battery_support | True |
| battery_type | Growatt ARK XH HV Battery System (7.68-25.6 kWh); BP variant: APX HV Battery (5-60 kWh) |
| battery_voltage_class | HV |
| battery_voltage_max_v | 950 |
| battery_voltage_min_v | 600 |
| communication_can | UNKNOWN |
| communication_ethernet | optional (LAN module) |
| communication_rs485 | True |
| communication_wifi | optional (WiFi/GPRS/4G/RF modules) |
| ct_support | true (TPM-CT-G 100A; SDM630MCT 40mA CT-type meter) |
| generator_input_support | UNKNOWN |
| grid_certifications | ['CE', 'VDE 0126', 'EN 50549', 'C10/C11', 'VFR 2019', 'G98/G99', 'AS 4777', '(Greece grid code; full list in datasheet)'] |
| grid_export_control | true (export limitation via documented meters/CT per manual) |
| grid_frequency_hz | 50/60 (45-55Hz/55-65Hz) |
| grid_voltage_v | 220/380, 230/400 (340-440V) |
| home_assistant_integration | UNKNOWN |
| max_ac_power_kw | 11 |
| max_battery_charge_current_a | 18.5 ('Max. operating current 18.5A' standard XH; 25A for BP series per manual) |
| max_battery_charge_power_kw | 10 |
| max_battery_discharge_current_a | 18.5 (standard XH; 25A BP series) |
| max_dc_voltage_v | 1100 |
| max_input_current_per_mppt_a | 16 |
| max_parallel_units | UNKNOWN |
| max_pv_input_power_w | 20000 |
| max_short_circuit_current_per_mppt_a | 20 |
| modbus_rtu | true ('RS485 (Modbus-RTU protocol)' per manual) |
| modbus_tcp | UNKNOWN |
| mppt_max_voltage_v | 1000 |
| mppt_min_voltage_v | 140 |
| num_mppt | 2 |
| officially_supported_battery_brands | ['Growatt (ARK XH HV Battery System; APX HV Battery for BP variant)'] |
| parallel_support | UNKNOWN |
| phase_type | three-phase |
| pv_inputs_per_mppt | 1 |
| rated_ac_power_kw | 10 |
| region_variant | EU/Global |
| smart_meter_support | true (manual names Growatt TPM-CT-G 100A, Eastron SDM630-Modbus V3, Eastron SDM630MCT 40mA, CHINT DTSU666 variants) |
| sources | [{'url': 'https://www.pvo-int.com/wp-content/uploads/2022/01/MOD-3-10KTL3-XH-Datasheet.pdf', 'title': 'MOD 3-10KTL3-XH datasheet (distributor mirror)', 'doc_type': 'datasheet', 'publisher': 'Growatt via PVO International', 'doc_date': '2022-01 (upload path)', 'language': 'en', 'accessed': '2026-09-01', 'confidence': 'manufacturer-documented'}, {'url': 'https://donauer.s3.eu-west-1.amazonaws.com/files/growattmod3-10ktl3-xhusermanualen20240575df997daa.pdf', 'title': 'MOD 3-10KTL3-XH Installation & Operation Manual (Version 00, copyright 2023)', 'doc_type': 'manual', 'publisher': 'Growatt via Donauer', 'revision': 'V00, 2023/2024', 'language': 'en', 'accessed': '2026-09-01', 'confidence': 'manufacturer-documented'}, {'url': 'https://solarmagazine.nl/u/webshop/datasheetgrowattmod-3-10ktl3-xh.pdf', 'title': 'MOD 3-10KTL3-XH datasheet (distributor mirror, older revision)', 'doc_type': 'datasheet', 'publisher': 'Growatt via Solar Magazine NL', 'language': 'en', 'accessed': '2026-09-01', 'confidence': 'manufacturer-documented'}] |
| startup_voltage_v | 160 |
| sunspec_support | UNKNOWN |
| topology | grid-tie (battery-ready hybrid via XH battery port; standard XH pairs with ARK XH HV battery, XH-BP variant with APX HV battery adds backup) |
Physical / mechanical
| cable_gland_sizes | UNKNOWN |
| depth_mm | 178 |
| height_mm | 387 |
| mounting_bolt_size | M6 expansion bolts; drilled hole Φ=8 mm, depth 55 mm (manual p.22) |
| mounting_hole_diameter_mm | 8 |
| mounting_hole_spacing_mm |
154 (bracket hole spacing, manual p.22)
MOD 3-10KTL3-XH Installation & Operation Manual (Version 00) — manual p.22, bracket hole spacing '154 mm', drill 'Φ=8 mm', depth '55mm'
|
| mounting_type | ['wall'] |
| screw_sizes | M6 (bracket to wall), M4 (inverter to bracket) |
| shipping_weight_kg | UNKNOWN |
| torque_specs |
wall bracket 5 N·m (M6, manual p.22); inverter-to-bracket securing screw 5 N·m (M4, manual p.23)
MOD 3-10KTL3-XH Installation & Operation Manual (Version 00) — manual p.22 '5 N·m M6'; p.23 '5 N·m M4'
|
| weight_kg |
14
MOD 3-10KTL3-XH Installation & Operation Manual (Version 00) — manual p.17, '14 kg'
|
| width_mm |
425
MOD 3-10KTL3-XH Installation & Operation Manual (Version 00) — manual p.17, '425*387*178mm'
|
Installation
| clearance_bottom_mm | 300 |
| clearance_front_mm | UNKNOWN |
| clearance_left_mm |
500
MOD 3-10KTL3-XH Installation & Operation Manual (Version 00) — manual p.20, '≥500mm' sides/top and '≥300mm' bottom
|
| clearance_right_mm | 500 |
| clearance_top_mm | 500 |
| direct_sunlight_restriction | 'Do not expose ... to direct sunlight, rain, snow' (manual p.18) |
| indoor_outdoor | indoor and outdoor (IP66) |
| max_installation_altitude_m | 3000 |
| mounting_orientation | vertical wall mounting on the supplied bracket |
| orientation_allowed | ['vertical', 'backward tilt ≤15°'] |
| orientation_forbidden | ['tilt greater than 15° from vertical'] |
| surface_requirements | fire-proof and high-temperature-resistant mounting surface (manual p.19) |
Environment
| cooling_method | natural heat dissipation (fanless) |
| fan_replaceable | not applicable (fanless) |
| ip_rating |
IP66
MOD 3-10KTL3-XH Installation & Operation Manual (Version 00) — manual p.72 spec table, 'IP66'
|
| max_altitude_m | 3000 |
| noise_level_db |
≤29 dB(A) (typical)
MOD 3-10KTL3-XH Installation & Operation Manual (Version 00) — manual p.72, '≤29dB(A)'
|
| operating_temperature_c | -25 to +60 (>45 °C derating) |
| relative_humidity | 0~100% operating; 5% RH to 95% RH storage |
| storage_temperature_c | -25 to +60 |
Interfaces & connectors
| ac_terminal_type | quick-connector terminal |
| digital_inputs | DRMS port on the 30-pin connector, pins 11-14 relay inputs (manual p.32) |
| dry_contacts | COM port pins 1 and 2 provide a 12 V signal output (manual p.13) |
| ethernet | optional (Shine LAN module) |
| modbus_rtu | yes ('RS485 (Modbus-RTU protocol)') |
| protocol_notes | Battery communication is carried on an RJ45 socket (manual p.34). Documented meters: Growatt TPM-CT-G 100A, Eastron SDM630-Modbus V3, Eastron SDM630MCT 40mA, CHINT DTSU666/3*220/5(80)A and /1.5(6)A. |
| pv_connector_type | H4 / MC4 (optional) - spec table 'H4/MC4 (OPT)' |
| rs485 | yes - on the 30-pin COM connector: pins 3-4 parallel bus, pins 5-6 meter, pins 7-8 battery (manual p.32) |
| usb | yes |
| wifi | optional (Shine WiFi / GPRS / 4G / RF modules) |
Controls & display
| buttons | single touch button - single / double / triple tap and long press (manual p.46) |
| display_type | OLED+LED |
| leds | leaf-shaped LED indicator; 'Green Solid' for normal operation (manual p.11) |
| local_display | True |
| mobile_app | ShinePhone (Growatt) |
| touchscreen | False |
Protection
| afci | AFCI protection - configurable (manual p.77); product page lists 'AFCI function optional' |
| anti_islanding | anti-islanding protection |
| ground_fault_protection | UNKNOWN (grid monitoring and RCMU documented; no separate GFDI entry) |
| insulation_monitoring | insulation resistance monitoring |
| integrated_dc_switch | True |
| residual_current_monitoring | residual-current monitoring unit |
| reverse_polarity | DC reverse-polarity protection |
| short_circuit | AC short-circuit protection |
| string_monitoring | string monitoring documented |
| surge_protection | DC surge protection and AC surge protection (product page: 'Type II SPD on AC&DC side') |
Certifications
| other | ['CE-EMC and CE-LVD certificates, VDE-AR-N 4105:2018 (I and II), VDE 0126-1-1, Austria, and N4105:2021 (CN-PV-210283R2 / CN-PV-210284R2) certificates are published on the official DE product page - located, not fetched'] |
| regional | ['CE'] |
Documents
compatibility-list
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
MOD 3000-10000TL3-XH + ARK XH Battery (system document, EN 202307) — located, not retrieved
rev 202307
datasheet
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
MOD 3-10KTL3-XH Datenblatt DE 202306 — located, not retrieved
rev 202306
installation-manual
MOD 3-10KTL3-XH Installation & Operation Manual (Version 00)
rev V00 (2023/2024)
installation-manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
MOD_3-10KTL3-XH_User_Manual_EN_202405 (current official revision) — located, not retrieved
rev 202405
product-page
MOD 3-10KTL3-XH product page (German)
product-page
MOD 3000-10000TL3-XH official product page
quick-start
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
MOD_3-10KTL3-XH_Quick_Guide_EN_202510 — located, not retrieved
rev 202510
Documented compatibility
Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.
inverter_meter
Eastron SDM630MCT
COMPATIBLEmanufacturer-documented
Growatt MOD 3-10KTL3-XH Installation & Operation Manual (2023, Version 00), Donauer-hosted PDF
CHINT DTSU666 (and DTSU666-CT variant)
COMPATIBLEmanufacturer-documented
Growatt MOD 3-10KTL3-XH Installation & Operation Manual (2023, Version 00), Donauer-hosted PDF
Recorded conflicts
max_pv_input_power_w Review required
15000 — solarmagazine.nl datasheet mirror: 'Max recommended PV power 15000W' (extraction showed column-mixing artifacts)
20000 — pvo-int.com datasheet mirror (2022-01): 'Max. recommended PV power: 20000W'
doc revision between datasheet versions, and possible table-parsing artifact in one mirror
max_battery_discharge_power_kw Review required
10 — both datasheet mirrors: 'Max discharging power: 10000W'
11 — manual 2023 V00: 'Max. discharge power: 11kW'
doc revision / manual covers BP-capable hardware
max_battery_discharge_power_kw Review required
10 — both datasheet mirrors: 'Max discharging power: 10000W'
11 — manual 2023 V00: 'Max. discharge power: 11kW'
doc revision / manual covers BP-capable hardware
max_pv_input_power_w Review required
15000 — solarmagazine.nl datasheet mirror: 'Max recommended PV power 15000W' (extraction showed column-mixing artifacts)
20000 — pvo-int.com datasheet mirror (2022-01): 'Max. recommended PV power: 20000W'
doc revision between datasheet versions, and possible table-parsing artifact in one mirror
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| COM port pin map | 30-pin COM: pins 1-2 12V dry-contact output; pins 3-4 RS485 parallel; pins 5-6 RS485 meter; pins 7-8 RS485 battery; pins 11-14 DRMS relay inputs |
| Max. tilt from vertical | ≤15° |
| Product-page highlights (DE) | 'Max. Wirkungsgrad 98,6%'; 'DC/AC bis zu 2,0'; 'Typ II SPD auf der AC&DC-Seite'; 'AFCI-Funktion optional'; 'Berührungstaste und OLED-Display' |