Growatt SPH 10000TL3 BH-UP
Official manufacturer EU verified Sept. 2, 2026
primary product image served on the official Growatt SPH 4000-10000TL3 BH-UP product page
Identity
| brand | Growatt |
| category | inverters |
| ean | UNKNOWN |
| generation | BH-UP |
| manufacturer | Growatt |
| market_version | EU/global (CE, VDE-AR-N 4105, CEI 0-21, EN 50549, G98, AS/NZS 4777) |
| model | SPH 10000TL3 BH-UP |
| mpn | UNKNOWN |
| product_family | SPH 4000-10000TL3 BH-UP (SPH 4000/5000/6000/7000/8000/10000TL3 BH-UP) |
| product_revision | UNKNOWN |
| product_status | active |
| region | EU |
| release_year | UNKNOWN |
| sku | UNKNOWN |
Electrical
| ac_coupling_support | UNKNOWN |
| backup_eps_output_support | True |
| battery_support | True |
| battery_type | Lithium battery / Lead-acid battery |
| battery_voltage_class | HV |
| battery_voltage_max_v | 550 |
| battery_voltage_min_v | 100 |
| communication_can | True |
| communication_ethernet | UNKNOWN |
| communication_rs485 | True |
| communication_wifi | True |
| ct_support | UNKNOWN |
| generator_input_support | UNKNOWN |
| grid_certifications | ['IEC 62040', 'VDE-AR-N 4105', 'VDE 0126', 'UTE C 15-712', 'C10/C11', 'EN50549', 'CEI 0-21', 'CEI 0-16', 'IEC62116', 'IEC61727', 'AS/NZS4777', 'G98'] |
| grid_export_control | UNKNOWN |
| home_assistant_integration | UNKNOWN |
| max_ac_power_kw | 10 |
| max_battery_charge_current_a | 25 |
| max_battery_charge_power_kw | 10 |
| max_battery_discharge_current_a | 25 |
| max_dc_voltage_v | 1000 |
| max_input_current_per_mppt_a | 16.9 |
| max_pv_input_power_w | 15000 |
| max_short_circuit_current_per_mppt_a | UNKNOWN (source gave identical 16.9A for both fields - likely duplicate/extraction error) |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| mppt_max_voltage_v | UNKNOWN (source text gave 120-1000V, identical to max DC voltage - possible table-parsing artifact) |
| mppt_min_voltage_v | 120 |
| num_mppt | 2 |
| officially_supported_battery_brands | UNKNOWN (see Growatt Approved LV Battery List, in sources) |
| phase_type | three-phase |
| pv_inputs_per_mppt | 1 |
| rated_ac_power_kw | 10 |
| smart_meter_support | UNKNOWN |
| startup_voltage_v | 120 |
| sunspec_support | UNKNOWN |
| topology | hybrid |
Physical / mechanical
| bracket_dimensions_mm | UNKNOWN |
| cable_entry_positions | UNKNOWN |
| cable_gland_sizes | UNKNOWN |
| depth_mm | 198 |
| enclosure_material | UNKNOWN |
| height_mm | 453 |
| housing_color | UNKNOWN |
| mounting_bolt_size | four expansion bolts in four Ф8 holes, drilled depth not less than 55 mm (user manual p.14) |
| mounting_hole_diameter_mm |
8
SPH 4000-10000TL3 BH-UP Installation & Operation Manual EN 202201 — user manual p.14, 'four Ф8 holes ... depth is not less than 55mm', 'four explosion bolt'
|
| mounting_hole_spacing_mm | UNKNOWN |
| mounting_type | ['wall'] |
| screw_sizes | M6 (mounting/grounding screws documented) |
| shipping_weight_kg | UNKNOWN |
| terminal_locations | UNKNOWN |
| torque_specs |
Upper cover screws 1.3 N·m (10.8 lbf.in); Shell 0.7 N·m (6.2 lbf.in); DC connector 1.8 N·m (16.0 lbf.in); M6 screwdriver 2 N·m (18 lbf.in); Grounding screw 2 N·m (18 lbf.in) (user manual p.61)
SPH 4000-10000TL3 BH-UP Installation & Operation Manual EN 202201 — user manual p.61 torque table
|
| weight_kg | 33 |
| width_mm |
505
SPH 4000-10000TL3 BH-UP Hybrid Inverter datasheet — datasheet general data, 'Dimensions (W / H / D) 505/453/198mm'; installation manual section 3.3 dimension chart '453 505 198'
|
Installation
| altitude_derating_note | UNKNOWN |
| clearance_bottom_mm | UNKNOWN |
| clearance_front_mm | UNKNOWN |
| clearance_left_mm | UNKNOWN |
| clearance_right_mm | UNKNOWN |
| clearance_top_mm | UNKNOWN |
| indoor_outdoor | indoor and outdoor ('use environment for IP65', user manual p.11) |
| installation_humidity_range | 5%-85% ('humidity should be 5%-85%', user manual p.11) |
| max_installation_altitude_m | 3000 |
| mounting_orientation | vertical or leaning back on plane ('SPH can be installed in vertical or lean back on plane', user manual p.11) |
| orientation_allowed | ['vertical', 'lean-back on plane'] |
| orientation_forbidden | UNKNOWN |
| surface_requirements | 'Do not install the unit on structures constructed of flammable or thermo labile materials' (user manual p.11) |
| two_person_lift_required | UNKNOWN |
Environment
| cooling_method | natural convection (spec table 'Cooling: Natural'; transformerless, no fan) |
| fan_replaceable | UNKNOWN |
| ik_rating | UNKNOWN |
| ip_rating | IP65 |
| max_altitude_m |
3000
SPH 4000-10000TL3 BH-UP Installation & Operation Manual EN 202201 — user manual p.60 spec table, '3000m'
|
| nema_rating | UNKNOWN |
| noise_level_db |
≤ 35 dB(A) (spec table p.60)
SPH 4000-10000TL3 BH-UP Installation & Operation Manual EN 202201 — user manual p.60 spec table, '≤ 35 dB(A)'
|
| operating_temperature_c | -25 to +60 (derating above 45 °C) |
| relative_humidity | 0~100% (spec table p.60); installation guidance 5%-85% (p.11) |
| storage_temperature_c | UNKNOWN |
Interfaces & connectors
| ac_terminal_type | screw/threaded-sleeve connector assembly (user manual p.16-17) |
| battery_terminal_type |
MC4 terminal (cable ≥ 4 mm² / 10 AWG, user manual p.22)
SPH 4000-10000TL3 BH-UP Installation & Operation Manual EN 202201 — user manual p.22, 'MC4 terminal', 'cable ≥4mm2/10 AWG'
|
| can | yes (spec table p.60) |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| protocol_notes | Energy meter connects over RJ45; supplied meter wire is 15 m (user manual p.21). WiFi/GPRS/Shine-Link are external USB/COM dongles (accessory part numbers in accessories). |
| pv_connector_type |
MC4 (cable ≥ 4 mm² / 12 AWG, user manual p.15)
SPH 4000-10000TL3 BH-UP Installation & Operation Manual EN 202201 — user manual p.15, 'MC4', 'cable ≥ 4mm2/12 AWG'
|
| rs485 | yes (spec table p.60 'RS485/CAN/USB: yes') |
| usb | yes (spec table p.60) |
Controls & display
| audible_alarm | UNKNOWN |
| buttons | 4 keys: ESC (cancel), Down, Enter, Up (user manual p.37) |
| display_type | LCD+LED (spec table p.60) |
| leds | Green on = SPH runs normally; Red on = fault state; Green blinking = alarm state; Red blinking = software updating (user manual p.7) |
| local_display | True |
| mobile_app | ShinePhone (Growatt) - accessory dongle required |
| touchscreen | False |
Protection
| anti_islanding | integrated (user manual p.59-60) |
| battery_reverse_protection | battery reverse protection (user manual p.59-60) |
| ground_fault_protection | ground fault monitoring (user manual p.59-60) |
| insulation_monitoring | integrated (user manual p.59-60) |
| integrated_breakers_fuses | UNKNOWN |
| integrated_dc_switch | True |
| over_current | UNKNOWN |
| residual_current_monitoring | integrated residual-current monitoring (user manual p.59-60) |
| reverse_polarity | DC reverse-polarity protection (user manual p.59-60) |
| short_circuit | AC short-circuit protection (user manual p.59-60) |
| surge_protection | integrated surge protection; datasheet/product page: 'Type II SPD on DC and AC side' |
Certifications
| grid_codes | ['VDE-AR-N 4105', 'VDE 0126', 'UTE C 15-712', 'C10/C11', 'EN50549', 'CEI 0-21', 'CEI 0-16', 'IEC62116', 'IEC61727', 'AS/NZS4777', 'G98'] |
| other | ['EU Declaration of Conformity SPH/SPA 4-10KTL3 BH-UP EN 202408 (located on official product page, not fetched)'] |
| regional | ['CE'] |
| safety | ['IEC 62040'] |
Warranty & service
| conditions | datasheet general-data row: 'Warranty: 5 years / 10 years Yes / Optional' |
| design_life_years | UNKNOWN |
| extended_options_years | [10] |
| fan_replaceable | not applicable (fanless, natural cooling) |
| service_intervals | UNKNOWN |
| standard_years |
5
SPH 4000-10000TL3 BH-UP Hybrid Inverter datasheet — datasheet general data, 'Warranty: 5 years / 10 years Yes / Optional'
|
Documents
datasheet
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
SPH4000-10000TL3 BH-UP official datasheet (en.growatt.com) — located, not retrieved
installation-manual
Installation Manual of SPH4-10KTL3 BH-UP (doc no. 044.0088200 / GR-UM-226-A-01)
rev GR-UM-226-A-01
product-page
SPH 4000-10000TL3 BH-UP official product page
quick-start
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
SPH 4000-10000TL3 BH-UP Quick Guide EN 202403 — located, not retrieved
rev 202403
user-manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
SPH 4000-10000TL3 BH-UP User Manual EN 202512 (current official revision) — located, not retrieved
rev 202512
Documented compatibility
Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.
inverter_battery
Pylontech US3000C
COMPATIBLEmanufacturer-documented
Pylontech Compatibility List Ver.2.35 (lists Growatt SPF/M/LXP models)
inverter_evse
go-e GmbH go-eCharger Gemini (11kW and 22kW variants)
COMPATIBLEinferred-from-electrical-parameters
go-e Gemini Datasheet (open local API/Modbus TCP/MQTT) + third-party EMS tools (evcc, openWB)
Recorded conflicts
physical.weight_kg Review required
33 — user manual EN 202201 Chart 3.1 (p.9) and installation manual 044.0088200 section 3.3 - both give 33 kg
30 — official datasheet (retonpower mirror) general data: 'Weight 30kg'
document revision, or net vs. packed/with-bracket weight; two manuals agree on 33 kg so that value is stored
max_short_circuit_current_per_mppt_a Review required
UNKNOWN — existing record
16.9 — official datasheet (retonpower mirror): 'Max. short-circuit current per MPP tracker 16.9A'
value was previously unresolvable because the manual extraction duplicated 16.9 A into two rows; the datasheet separates them
max_input_current_per_mppt_a Review required
16.9 — existing record, taken from user manual EN 202201 spec table (extraction gave 16.9A for BOTH max input current and max short-circuit current)
13.5 — official datasheet (retonpower mirror): 'Max. input current per MPP tracker 13.5A'; official installation manual 044.0088200 (hornbach mirror): 'Max. input current: 13.5A*2'
the existing 16.9 A almost certainly came from a table-parsing artifact in the user manual; two independent official documents give 13.5 A input current and 16.9 A short-circuit current per tracker, which is the internally coherent pair
physical.weight_kg Review required
33 — user manual EN 202201 Chart 3.1 (p.9) and installation manual 044.0088200 section 3.3 - both give 33 kg
30 — official datasheet (retonpower mirror) general data: 'Weight 30kg'
document revision, or net vs. packed/with-bracket weight; two manuals agree on 33 kg so that value is stored
max_short_circuit_current_per_mppt_a Review required
UNKNOWN — existing record
16.9 — official datasheet (retonpower mirror): 'Max. short-circuit current per MPP tracker 16.9A'
value was previously unresolvable because the manual extraction duplicated 16.9 A into two rows; the datasheet separates them
max_input_current_per_mppt_a Review required
16.9 — existing record, taken from user manual EN 202201 spec table (extraction gave 16.9A for BOTH max input current and max short-circuit current)
13.5 — official datasheet (retonpower mirror): 'Max. input current per MPP tracker 13.5A'; official installation manual 044.0088200 (hornbach mirror): 'Max. input current: 13.5A*2'
the existing 16.9 A almost certainly came from a table-parsing artifact in the user manual; two independent official documents give 13.5 A input current and 16.9 A short-circuit current per tracker, which is the internally coherent pair
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| AC output | Max. output current 15.2A; THDi <3%; adjustable power factor 0.8 leading…0.8 lagging; Nominal AC voltage (range) 230V/400V (310~476V) |
| Backup/EPS: Max. AC output power / Switch time | 10000W / <10ms |
| Battery | Continuous charging and discharging power 10000W |
| Chart 3.1 dimension letters (user manual EN 202201, p.9) | A(mm) 505, B(mm) 544, C(mm) 198.5, D(mm) 453.5, weight(kg) 33 |
| Efficiency | MAX. efficiency 98.2%; European efficiency 97.5% |
| MPP voltage range | 120V-1000V/600V |
| Product page highlights | 'UPS function, 10ms transition'; '100% three-phase imbalance output'; 'Smart phase-level power control'; 'Type II SPD on DC and AC side'; 'DC/AC ratio up to 1.5' |