ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseInverters

Huawei SUN2000-6K-MAP0

Official manufacturer global verified Sept. 3, 2026

Identity

category inverters
ean UNKNOWN
generation MAP0 (three-phase 1100 V DC platform, 160-1000 V MPPT window, 16 A/MPPT, IP66)
hardware_revision UNKNOWN
legacy_name UNKNOWN
manufacturer Huawei
manufacturer_legal_entity UNKNOWN
market_version UNKNOWN
model SUN2000-6K-MAP0
mpn UNKNOWN
order_code UNKNOWN
product_family SUN2000-5/6/8/10/12K-MAP0
product_status active
product_status_detail active - new
product_status_evidence Product page at https://solar.huawei.com/en/products/sun2000-5-12k-map0/ carries a 'NEW' designation next to the model name (fetched 2026-09-03); live /specs/ page also fetched.
region global
release_year UNKNOWN
sku UNKNOWN
subcategory three-phase residential hybrid inverter with three-phase backup (Huawei 'Smart Energy Controller')
variant_note MAP0 drops the 'KTL' token: the model is 'SUN2000-10K-MAP0', not 'SUN2000-10KTL-MAP0'. It is the current-generation counterpart to the older -M1 family at the same power points, but is a materially different unit: 160 V startup vs 200 V, 160-1000 V MPPT window vs 140-980 V, 16 A/MPPT vs 11 A, 22 A Isc vs 15 A, IP66 vs IP65, 490 x 460 x 130 mm vs 525 x 470 x 146.5 mm, 21 kg vs 17 kg, and true three-phase backup via SmartGuard-63A-T0 vs single-phase-rated Backup Box-B1. Do not substitute.

Electrical

dc_ac_ratio_guidance UNKNOWN
european_efficiency 97.7%
max_ac_apparent_power_va 6600
max_active_power_w UNKNOWN (no separate max active power row on the fetched specs page)
max_dc_voltage_v 1100
max_efficiency 98.6%
max_input_current_per_mppt_a 16
max_output_current_a 10.0
max_recommended_pv_power_w 11000
max_short_circuit_current_per_mppt_a 22
mppt_voltage_max_v 1000
mppt_voltage_min_v 160
nominal_frequency 50 Hz / 60 Hz
nominal_voltage 220 V AC / 380 V AC, 230 V AC / 400 V AC, 240 V AC / 415 V AC 3W/N + PE (three-phase)
num_mppt 2
num_pv_inputs 2
num_pv_inputs_note 'Number of MPP trackers 2' and 'Max. input per MPP tracker 1' -> 2 DC inputs total on a single unit.
overload_capability 110%
oversizing_limits Recommended max. PV power 11000 Wp against 6000 W rated AC (ratio ~1.83:1).
power_factor_range 0.8 leading ... 0.8 lagging
rated_ac_power_w 6000
rated_input_voltage_v 600
rated_output_current_a UNKNOWN (no 'Rated output current' row on the fetched specs page)
startup_voltage_v 160
string_rules UNKNOWN
thd <= 3%
voltage_range UNKNOWN

Physical / mechanical

cooling Natural convection
depth_mm 130
dimensions_note 'Dimensions (incl. mounting brackets) 490 mm x 460 mm x 130 mm'; 'Weight (incl. mounting brackets) 21 kg'.
enclosure_material UNKNOWN
height_mm 460
ip_rating IP66
mounting_type UNKNOWN
noise_db <= 29 dB
weight_kg 21.0
width_mm 490

Installation

ac_connector UNKNOWN
cable_entry UNKNOWN
dc_connector UNKNOWN
dc_switch Yes - 'input-side disconnection' listed among protection features
mounting UNKNOWN

Environment

altitude_note 'Max. operating altitude 4000 m'
max_altitude_m 4000
operating_temperature -25 C - +60 C
relative_humidity 0% - 100% RH

Interfaces & connectors

can UNKNOWN
display LED Indicators
dongle_support Smart Dongle-WLAN-FE (optional); Smart Dongle-4G for 4G/3G/2G (optional); SmartAssistant SA4H-A02 (optional)
ethernet Optional, via Smart Dongle-WLAN-FE
fe Optional, via Smart Dongle-WLAN-FE
fusionsolar_monitoring Yes - 'LED Indicators; Integrated WLAN + FusionSolar APP'
local_api_availability UNKNOWN
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
register_doc_availability UNKNOWN
rs485 True
smartlogger_compatibility UNKNOWN
usb UNKNOWN
wlan Yes, integrated WLAN

Protection

ac_overcurrent_protection Yes
ac_overvoltage_protection Yes
ac_short_circuit_protection Yes
afci Yes - 'arc fault protection'
anti_islanding Yes
connector_temperature_detection Yes - 'connector temperature detection (PV & Battery)'
dc_reverse_polarity_protection Yes
dc_switch Yes - 'input-side disconnection device'
insulation_monitoring Yes - 'insulation detection'
rcmu Yes - 'residual current detection'
ripple_receiver_control Yes
surge_protection DC surge protection: TYPE II per EN/IEC 61643-11; AC surge protection: TYPE II per EN/IEC 61643-11

Certifications

grid_standards ['IEC61727', 'IEC62116', 'MEA/PEA', 'G99', 'Philippine Grid Code Resolution No. 07', 'NRS 097-2-1', 'EN50549-1', 'VDE4105', 'UTE15-712-1/VFR 2019', 'UNE217002', 'NTS631', 'RD244(UNE217001)', 'PPDS', 'ROGA', 'TOR Erzeuger', 'CEI 0-21:2020-12 V1', 'C10/C11']
regional_certifications UNKNOWN
safety_standards ['EN/IEC62109-1', 'EN/IEC62109-2']

Warranty & service

extension_options UNKNOWN
note No warranty row. The product page states a '25-year engineered service life with enhanced protection', which is a design-life claim, not a warranty term.
standard_warranty UNKNOWN

Documents

datasheet SUN2000-5/6/8/10/12K-MAP0 Specs page rev UNKNOWN
datasheet SUN2000-5/6/8/10/12K-MAP0 product page rev UNKNOWN

Recorded conflicts

battery.supported_battery_families Review required
LUNA2000-5/10/15-S0 / LUNA2000-7/14/21-S1 — MAP0 specs page, row 'Compatible battery model'
LUNA2000-5/10/15-S0 and LUNA2000-5/7/10/12/14/15/17/19/21-S1 — MAP0 product page accessory list

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

110% overload (off grid)Continuous
150% overload (off grid)5 min (3-phase) / 5 min (Single-phase)
200% overload (off grid)10 seconds
Asymmetric load support100% three-phase
Connector temperature detectionPV & Battery
Engineered service life (product page)25-year engineered service life with enhanced protection
Nighttime power< 5.5 W
Overload capability (on grid)110%
Ripple receiver controlYes
identity.product_statusactive - new