Knowledge Base ›
Inverters
Huawei SUN2000-8K-LC0
Official manufacturer
Regional page: the certificate/grid-code list on the fetched specs page is 'ABNT16149/16150:2013, NRS 097-2-1, PEA, MEA' (Brazil / South Africa / Thailand), with no EU grid codes. Treat this record as the LATAM/APAC/Africa market version; an EU market version was not fetched.
verified Sept. 3, 2026
Identity
| category |
inverters
|
| ean |
UNKNOWN
|
| generation |
LC0 (single-phase 600 V DC platform, 40-560 V MPPT window, THREE MPPTs, IP66)
|
| hardware_revision |
UNKNOWN
|
| legacy_name |
UNKNOWN
|
| manufacturer |
Huawei
|
| manufacturer_legal_entity |
UNKNOWN
|
| market_version |
UNKNOWN
|
| model |
SUN2000-8K-LC0
|
| mpn |
UNKNOWN
|
| order_code |
UNKNOWN
|
| product_family |
SUN2000-8/10K-LC0
|
| product_status |
active
|
| product_status_evidence |
Live /specs/ page in the solar.huawei.com catalogue at https://solar.huawei.com/en/products/sun2000-8-10k-lc0/specs/ (fetched 2026-09-03).
|
| region |
Regional page: the certificate/grid-code list on the fetched specs page is 'ABNT16149/16150:2013, NRS 097-2-1, PEA, MEA' (Brazil / South Africa / Thailand), with no EU grid codes. Treat this record as the LATAM/APAC/Africa market version; an EU market version was not fetched.
|
| release_year |
UNKNOWN
|
| sku |
UNKNOWN
|
| subcategory |
single-phase high-power residential hybrid inverter (3 MPPT)
|
| variant_note |
LC0 drops the 'KTL' token: the model is 'SUN2000-10K-LC0'. It is NOT a bigger LB0: LC0 has THREE MPP trackers (LB0 and L1 have two), a 25 A battery operating current (LB0 16.5 A, L1 15 A) and cooling documented as 'Natural convection / Smart Air Cooling'. It is also NOT a three-phase unit despite its 8-10 kW rating - grid connection is single-phase.
|
Electrical
| dc_ac_ratio_guidance |
UNKNOWN
|
| european_efficiency |
97.5%
|
| max_ac_apparent_power_va |
8800
|
| max_active_power_w |
UNKNOWN (no separate max active power row on the fetched specs page)
|
| max_dc_voltage_v |
600
|
| max_efficiency |
98.1%
|
| max_input_current_per_mppt_a |
16
|
| max_output_current_a |
40.0
|
| max_recommended_pv_power_w |
12000
|
| max_short_circuit_current_per_mppt_a |
20
|
| mppt_voltage_max_v |
560
|
| mppt_voltage_min_v |
40
|
| nominal_frequency |
50 Hz / 60 Hz
|
| nominal_voltage |
220 V AC / 230 V AC / 240 V AC, L/N + PE, single-phase
|
| num_mppt |
3
|
| num_pv_inputs |
3
|
| num_pv_inputs_note |
The specs page gives 'Number of MPP trackers 3' and 'Max. number of inputs 3' -> 3 DC inputs total, i.e. one string per MPPT, on a single unit. The page does not print an explicit 'inputs per MPPT' row.
|
| oversizing_limits |
Recommended max. PV power 12000 Wp against 8000 W rated AC (1.5:1).
|
| power_factor_range |
0.8 leading ... 0.8 lagging
|
| rated_ac_power_w |
8000
|
| rated_input_voltage_v |
360
|
| rated_output_current_a |
UNKNOWN (no 'Rated output current' row on the fetched specs page)
|
| startup_voltage_v |
50
|
| string_rules |
UNKNOWN
|
| thd |
<= 3%
|
| voltage_range |
UNKNOWN
|
Physical / mechanical
| cooling |
Natural convection / Smart Air Cooling (printed as a combined value)
|
| depth_mm |
150
|
| dimensions_note |
'Dimensions (W x H x D) 425 mm x 376.5 mm x 150 mm' for both models; weight differs by model (8K = 14.5 kg, 10K = 15 kg).
|
| enclosure_material |
UNKNOWN
|
| height_mm |
376.5
|
| ip_rating |
IP66
|
| mounting_type |
UNKNOWN
|
| noise_db |
UNKNOWN
|
| weight_kg |
14.5
|
| width_mm |
425
|
Installation
| ac_connector |
UNKNOWN
|
| cable_entry |
UNKNOWN
|
| dc_connector |
UNKNOWN
|
| dc_switch |
UNKNOWN
|
| mounting |
UNKNOWN
|
Environment
| altitude_note |
'Operating altitude 0 - 4000 m (Derated above 2000 m)'
|
| max_altitude_m |
4000
|
| operating_temperature |
-25 C to +60 C (-13 F to +140 F)
|
| relative_humidity |
0% - 100% RH
|
Interfaces & connectors
| can |
UNKNOWN
|
| display |
LED indicators
|
| dongle_support |
Smart Dongle-WLAN-FE (optional)
|
| ethernet |
Optional, via Smart Dongle-WLAN-FE
|
| fe |
Optional, via Smart Dongle-WLAN-FE
|
| fusionsolar_monitoring |
Yes - 'LED indicators; integrated WLAN + FusionSolar app'
|
| local_api_availability |
UNKNOWN
|
| modbus_rtu |
UNKNOWN
|
| modbus_tcp |
UNKNOWN
|
| register_doc_availability |
UNKNOWN
|
| rs485 |
True
|
| smartlogger_compatibility |
UNKNOWN
|
| usb |
UNKNOWN
|
| wlan |
Yes, integrated WLAN
|
Protection
| ac_overcurrent_protection |
Yes
|
| ac_overvoltage_protection |
Yes
|
| ac_short_circuit_protection |
Yes
|
| afci |
Yes - 'Arc fault protection'
|
| anti_islanding |
Yes
|
| dc_reverse_polarity_protection |
Yes
|
| dc_switch |
UNKNOWN
|
| insulation_monitoring |
Yes
|
| over_heat_protection |
Yes
|
| rcmu |
Yes - 'Residual current monitoring unit'
|
| surge_protection |
DC surge protection: Yes, compatible with TYPE II protection class according to EN/IEC 61643-11; AC surge protection: same
|
Certifications
| grid_standards |
['ABNT16149/16150:2013', 'NRS 097-2-1', 'PEA', 'MEA']
|
| note |
The grid-connection list on the fetched page contains no EU/UK codes (no G98/G99, no VDE-AR-N-4105, no CEI 0-21). This is a regional catalogue page; do not assume EU grid-code compliance from it.
|
| regional_certifications |
UNKNOWN
|
| safety_standards |
['IEC62109-1', 'IEC62109-2', 'EN 61000-6 series', 'EN 62920 EMC', 'EN 55011 EMC', 'ETSI EN 301-489-1 EMC', 'ETSI EN 301 489-17 EMC', 'EN 61000 3-11', 'EN 61000 3-12', 'IEC61000 2-2']
|
Warranty & service
| extension_options |
UNKNOWN
|
| note |
No warranty row on the fetched specs page.
|
| standard_warranty |
UNKNOWN
|
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Battery charging from grid | Yes |
| Certificates | EN 62920 EMC, EN 55011 EMC, ETSI EN 301-489-1 EMC, ETSI EN 301 489-17 EMC |
| Cooling | Natural convection / Smart Air Cooling |
Build a system with this product