SolaX Power X3-Hybrid G4 10.0D
Official manufacturer global verified Aug. 31, 2026
Product-page hero image, visually verified as a front three-quarter product photo
Identity
| brand | SolaX |
| category | inverters |
| ean | UNKNOWN |
| generation | G4 |
| manufacturer | SolaX Power |
| market_version | UNKNOWN |
| model | X3-Hybrid G4 10.0D |
| mpn | X3-HYBRID-10.0-D |
| product_family | X3-Hybrid G4 three-phase residential hybrid |
| product_revision | UNKNOWN |
| product_status | active |
| region | global |
| release_year | UNKNOWN |
| sku | UNKNOWN |
| suffix_meaning | D = with integrated DC switch (M = supplied with the external X3-Matebox) |
Electrical
| ac_coupling_support | UNKNOWN |
| backup_eps_output_support | True |
| battery_support | True |
| battery_type | Lithium / Lead-acid |
| battery_voltage_class | HV |
| battery_voltage_max_v | 800 |
| battery_voltage_min_v | 120 |
| communication_can | UNKNOWN |
| communication_ethernet | UNKNOWN (optional Pocket LAN) |
| communication_rs485 | True |
| communication_wifi | True |
| ct_support | True |
| generator_input_support | UNKNOWN |
| grid_certifications | ['EN/IEC62109-1/-2', 'VDE4105', 'G99', 'G98', 'AS4777', 'EN50549', 'CEI 0-21', 'IEC61727', 'NRS-097-2-1', 'RD1699', 'TOR'] |
| grid_export_control | UNKNOWN |
| home_assistant_integration | UNKNOWN |
| max_ac_power_kw | 11 |
| max_battery_charge_current_a | 30 |
| max_battery_charge_power_kw | UNKNOWN |
| max_battery_discharge_current_a | 30 |
| max_dc_voltage_v | 1000 |
| max_input_current_per_mppt_a | 28A / 16A (asymmetric between the two MPPTs) |
| max_pv_input_power_w | 20000 |
| max_short_circuit_current_per_mppt_a | 35A / 20A (asymmetric between the two MPPTs) |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| mppt_max_voltage_v | 950 |
| mppt_min_voltage_v | 180 |
| num_mppt | 2 |
| officially_supported_battery_brands | ['SolaX Power'] |
| officially_supported_battery_models |
['T-BAT SYS-HV-5.8', 'T-BAT SYS-HV-3.0', 'T-BAT-SYS-HV-R2.5', 'T-BAT-SYS-HV-R3.6', 'T-BAT-SYS-HV-S2.5', 'T-BAT-SYS-HV-S3.6', 'TSYS-HS51']
X3-Hybrid G4 User Manual (EN) — manual p.53, section 8.5 battery-compatibility table
|
| phase_type | three-phase |
| pv_inputs_per_mppt | 2 |
| rated_ac_power_kw | 10 |
| smart_meter_support | True |
| startup_voltage_v | 200 |
| sunspec_support | UNKNOWN |
| topology | hybrid |
Physical / mechanical
| bracket_dimensions_mm | UNKNOWN |
| cable_entry_positions | bottom of the unit |
| cable_gland_sizes | UNKNOWN |
| depth_mm | 199 |
| enclosure_material | UNKNOWN |
| height_mm | 503 |
| housing_color | UNKNOWN |
| mounting_bolt_size | expansion bolt with tube; M5 screw secures the inverter to the bracket |
| mounting_hole_diameter_mm | 8 |
| mounting_hole_spacing_mm | 5 bracket holes; dimensions marked '360' and '162 162' on the bracket drawing (manual p.35, Figure 7-4) |
| mounting_plate_dimensions_mm | UNKNOWN |
| mounting_type | ['wall'] |
| screw_sizes | M5 |
| shipping_weight_kg | UNKNOWN |
| terminal_locations | DC switch, PV input terminal, battery connection terminal, Dongle/Upgrade terminal, COM, Battery BMS, Meter/CT, Grid connection, grounding point, CAN1, CAN2, DRM, OFF, EPS connection (manual pp.38-39, Table 8-1) |
| torque_specs |
M5 securing screws 2.0 +/- 0.2 N.m (manual p.37, Figure 7-10)
X3-Hybrid G4 User Manual (EN) — manual p.37, Figure 7-10: '2.0 +/- 0.2 N.m'
|
| weight_kg |
30 +/- 1
X3-HYBRID G4 Three-phase Residential Hybrid Inverter Datasheet — datasheet 'Net weight: 30 +/- 1 kg'
|
| width_mm |
503
X3-HYBRID G4 Three-phase Residential Hybrid Inverter Datasheet — datasheet 'Dimensions (W x H x D): 503 x 503 x 199 mm'
|
Installation
| altitude_derating_note | manual p.25 prohibits installation where the altitude exceeds 3000 m; datasheet 'Max. operation altitude 3000 m' |
| clearance_bottom_mm | 300 |
| clearance_front_mm |
120
X3-Hybrid G4 User Manual (EN) — manual pp.27-28, Figures 7-4/7-5: '>= 300 mm' around, '120 mm' front
|
| clearance_left_mm | 300 |
| clearance_right_mm | 300 |
| clearance_top_mm | 300 |
| coastal_restriction | install at least 500 metres away from the coast (manual p.26) |
| cooling_airflow_requirements | natural cooling / smart air cooling |
| direct_sunlight_restriction | avoid direct sunlight, rain exposure and snow accumulation (manual p.26) |
| drill_hole_depth_mm |
65
X3-Hybrid G4 User Manual (EN) — manual p.36 'Use a diameter-8 drill bit. The depth of the holes should be 65 mm'
|
| drill_hole_diameter_mm | 8 |
| indoor_outdoor | indoor or outdoor (IP65); avoid rain and snow accumulation |
| installation_humidity_range | UNKNOWN |
| installation_temperature_range_c | UNKNOWN |
| max_installation_altitude_m | 3000 |
| minimum_wall_thickness_mm | UNKNOWN |
| mounting_orientation | vertical wall mount; maximum back tilt 5 degrees, no forward tilt |
| orientation_allowed | ['vertical wall', 'back tilt up to 5 degrees'] |
| orientation_forbidden | ['forward tilt', 'side tilt', 'upside down', 'horizontal'] |
| surface_requirements | installation carrier must be non-flammable material such as solid brick or concrete, capable of supporting four times the inverter's weight (manual p.27) |
| two_person_lift_required | UNKNOWN |
| ventilation_requirements | natural ventilation; keep the stated clearances free |
Environment
| cooling_method | natural cooling / smart air cooling |
| corrosion_class | UNKNOWN |
| fan_replaceable | UNKNOWN |
| ik_rating | UNKNOWN |
| ip_rating | IP65 |
| max_altitude_m | 3000 |
| nema_rating | UNKNOWN |
| noise_level_db | UNKNOWN |
| operating_temperature_c | -35 ~ 60 (> 45 C derating) |
| pollution_degree | UNKNOWN |
| relative_humidity | 4 ~ 100 % RH (condensing) |
| salt_mist_resistance | UNKNOWN (manual instead requires >=500 m distance from the coast) |
| storage_temperature_c | UNKNOWN |
| uv_resistance | UNKNOWN |
Interfaces & connectors
| ac_terminal_type | grid connection terminal with AC protective cover |
| backup_eps_terminal | EPS connection terminal |
| battery_terminal_type | supplied battery connectors (positive/negative), manual p.32 |
| bluetooth | UNKNOWN |
| can | yes (CAN1 and CAN2 ports) |
| cellular | optional Pocket 4G dongle |
| drm | yes |
| dry_contacts | OFF terminal listed in the port table |
| ethernet | optional Pocket LAN dongle |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| protocol_notes | Datasheet communication row verbatim: 'CT/Meter (optional), External control RS485, Pocket WiFi (Optional: Pocket LAN/4G), DRM'. Communication wiring uses CAT5E (RJ45). |
| pv_connector_type | supplied PV connectors (positive/negative); brand not named in the manual |
| rs485 | yes (external control RS485; Meter/CT port) |
| sunspec | UNKNOWN |
| usb | Dongle/Upgrade terminal |
| wifi | optional Pocket WiFi dongle |
Controls & display
| audible_alarm | UNKNOWN |
| buttons | ESC key referenced (manual p.44) |
| display_type | LCD panel including screen, indicators and keys (manual p.4); size not stated |
| leds | indicators on the LCD panel (details not given in the fetched pages) |
| local_display | True |
| mobile_app | UNKNOWN (SolaX Cloud ecosystem via Pocket dongles) |
| remote_display_option | UNKNOWN |
| status_indicators | UNKNOWN |
| touchscreen | False |
| web_interface | UNKNOWN |
Protection
| afci | Optional |
| anti_islanding | yes (grid monitoring) |
| back_feed_current_monitoring | yes |
| dc_injection_monitoring | yes |
| ground_fault_protection | yes (earth-fault monitoring per IEC 62109-2 clause 13.9, manual p.48) |
| insulation_monitoring | yes (DC isolation) |
| integrated_breakers_fuses | UNKNOWN |
| integrated_dc_switch | True |
| over_current | yes (AC overcurrent) |
| over_temperature | yes |
| over_voltage | yes (over/under voltage protection) |
| overvoltage_category | Mains: III, Battery: II, PV: II |
| protection_class | UNKNOWN |
| residual_current_monitoring |
yes - integrated Type-B Residual Current Monitoring Unit (RCMU)
X3-Hybrid G4 User Manual (EN) — manual pp.2-3: integrated Type-B RCMU
|
| reverse_polarity | yes (DC reverse-polarity protection) |
| short_circuit | yes (AC short-circuit) |
| surge_protection | DC: Type II, AC: Type II |
| under_voltage | yes |
Certifications
| emc | [] |
| grid_codes |
['VDE4105', 'G99', 'G98', 'AS4777', 'EN50549', 'CEI 0-21', 'IEC61727', 'PEA/MEA', 'NRS-097-2-1', 'RD1699', 'TOR']
X3-HYBRID G4 Three-phase Residential Hybrid Inverter Datasheet — datasheet certification row
|
| other | [] |
| regional | ['CE', 'TUV', 'RCM'] |
| safety | ['EN/IEC62109-1', 'EN/IEC62109-2'] |
Warranty & service
| conditions | UNKNOWN |
| cycle_life | N/A |
| design_life_years | UNKNOWN |
| extended_options_years | UNKNOWN |
| fan_replaceable | UNKNOWN |
| field_replaceable_parts | UNKNOWN |
| fuse_replaceable | UNKNOWN |
| service_intervals | UNKNOWN |
| standard_years | UNKNOWN |
Documents
Documented compatibility
Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.
inverter_battery
SolaX Power Triple Power T-BAT-SYS-HV 5.8 (T58)
COMPATIBLEofficially-verified
SolaX T-BAT-SYS-HV Datasheet
inverter_evse
go-e GmbH go-eCharger Gemini (11kW and 22kW variants)
COMPATIBLEinferred-from-electrical-parameters
go-e Gemini Datasheet (open local API/Modbus TCP/MQTT) + third-party EMS tools (evcc, openWB)
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Efficiency | Max. 98.0 %, European 97.7 % |
| PV wire / grid wire cross-section | 4-6 mm2 (PV), 5-6 mm2 (grid) |
| Parallel capability | on-grid and off-grid parallel function, up to 150kW |
| Power consumption (night) | < 40 W for standby, < 5 W for idle |
| Rated EPS output power / Peak EPS output power / Switchover time | 10 kVA / 18.0 kVA, 10 s / < 10 ms |