ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseInverters

SolaX Power X3-Hybrid G4 10.0D

Official manufacturer global verified Aug. 31, 2026

Identity

brand SolaX
category inverters
ean UNKNOWN
generation G4
manufacturer SolaX Power
market_version UNKNOWN
model X3-Hybrid G4 10.0D
mpn X3-HYBRID-10.0-D
product_family X3-Hybrid G4 three-phase residential hybrid
product_revision UNKNOWN
product_status active
region global
release_year UNKNOWN
sku UNKNOWN
suffix_meaning D = with integrated DC switch (M = supplied with the external X3-Matebox)

Electrical

ac_coupling_support UNKNOWN
backup_eps_output_support True
battery_support True
battery_type Lithium / Lead-acid
battery_voltage_class HV
battery_voltage_max_v 800
battery_voltage_min_v 120
communication_can UNKNOWN
communication_ethernet UNKNOWN (optional Pocket LAN)
communication_rs485 True
communication_wifi True
ct_support True
generator_input_support UNKNOWN
grid_certifications ['EN/IEC62109-1/-2', 'VDE4105', 'G99', 'G98', 'AS4777', 'EN50549', 'CEI 0-21', 'IEC61727', 'NRS-097-2-1', 'RD1699', 'TOR']
grid_export_control UNKNOWN
home_assistant_integration UNKNOWN
max_ac_power_kw 11
max_battery_charge_current_a 30
max_battery_charge_power_kw UNKNOWN
max_battery_discharge_current_a 30
max_dc_voltage_v 1000
max_input_current_per_mppt_a 28A / 16A (asymmetric between the two MPPTs)
max_pv_input_power_w 20000
max_short_circuit_current_per_mppt_a 35A / 20A (asymmetric between the two MPPTs)
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
mppt_max_voltage_v 950
mppt_min_voltage_v 180
num_mppt 2
officially_supported_battery_brands ['SolaX Power']
officially_supported_battery_models ['T-BAT SYS-HV-5.8', 'T-BAT SYS-HV-3.0', 'T-BAT-SYS-HV-R2.5', 'T-BAT-SYS-HV-R3.6', 'T-BAT-SYS-HV-S2.5', 'T-BAT-SYS-HV-S3.6', 'TSYS-HS51']
X3-Hybrid G4 User Manual (EN) — manual p.53, section 8.5 battery-compatibility table
phase_type three-phase
pv_inputs_per_mppt 2
rated_ac_power_kw 10
smart_meter_support True
startup_voltage_v 200
sunspec_support UNKNOWN
topology hybrid

Physical / mechanical

bracket_dimensions_mm UNKNOWN
cable_entry_positions bottom of the unit
cable_gland_sizes UNKNOWN
depth_mm 199
enclosure_material UNKNOWN
height_mm 503
housing_color UNKNOWN
mounting_bolt_size expansion bolt with tube; M5 screw secures the inverter to the bracket
mounting_hole_diameter_mm 8
mounting_hole_spacing_mm 5 bracket holes; dimensions marked '360' and '162 162' on the bracket drawing (manual p.35, Figure 7-4)
mounting_plate_dimensions_mm UNKNOWN
mounting_type ['wall']
screw_sizes M5
shipping_weight_kg UNKNOWN
terminal_locations DC switch, PV input terminal, battery connection terminal, Dongle/Upgrade terminal, COM, Battery BMS, Meter/CT, Grid connection, grounding point, CAN1, CAN2, DRM, OFF, EPS connection (manual pp.38-39, Table 8-1)
torque_specs M5 securing screws 2.0 +/- 0.2 N.m (manual p.37, Figure 7-10)
X3-Hybrid G4 User Manual (EN) — manual p.37, Figure 7-10: '2.0 +/- 0.2 N.m'
weight_kg 30 +/- 1
X3-HYBRID G4 Three-phase Residential Hybrid Inverter Datasheet — datasheet 'Net weight: 30 +/- 1 kg'
width_mm 503
X3-HYBRID G4 Three-phase Residential Hybrid Inverter Datasheet — datasheet 'Dimensions (W x H x D): 503 x 503 x 199 mm'

Installation

altitude_derating_note manual p.25 prohibits installation where the altitude exceeds 3000 m; datasheet 'Max. operation altitude 3000 m'
clearance_bottom_mm 300
clearance_front_mm 120
X3-Hybrid G4 User Manual (EN) — manual pp.27-28, Figures 7-4/7-5: '>= 300 mm' around, '120 mm' front
clearance_left_mm 300
clearance_right_mm 300
clearance_top_mm 300
coastal_restriction install at least 500 metres away from the coast (manual p.26)
cooling_airflow_requirements natural cooling / smart air cooling
direct_sunlight_restriction avoid direct sunlight, rain exposure and snow accumulation (manual p.26)
drill_hole_depth_mm 65
X3-Hybrid G4 User Manual (EN) — manual p.36 'Use a diameter-8 drill bit. The depth of the holes should be 65 mm'
drill_hole_diameter_mm 8
indoor_outdoor indoor or outdoor (IP65); avoid rain and snow accumulation
installation_humidity_range UNKNOWN
installation_temperature_range_c UNKNOWN
max_installation_altitude_m 3000
minimum_wall_thickness_mm UNKNOWN
mounting_orientation vertical wall mount; maximum back tilt 5 degrees, no forward tilt
orientation_allowed ['vertical wall', 'back tilt up to 5 degrees']
orientation_forbidden ['forward tilt', 'side tilt', 'upside down', 'horizontal']
surface_requirements installation carrier must be non-flammable material such as solid brick or concrete, capable of supporting four times the inverter's weight (manual p.27)
two_person_lift_required UNKNOWN
ventilation_requirements natural ventilation; keep the stated clearances free

Environment

cooling_method natural cooling / smart air cooling
corrosion_class UNKNOWN
fan_replaceable UNKNOWN
ik_rating UNKNOWN
ip_rating IP65
max_altitude_m 3000
nema_rating UNKNOWN
noise_level_db UNKNOWN
operating_temperature_c -35 ~ 60 (> 45 C derating)
pollution_degree UNKNOWN
relative_humidity 4 ~ 100 % RH (condensing)
salt_mist_resistance UNKNOWN (manual instead requires >=500 m distance from the coast)
storage_temperature_c UNKNOWN
uv_resistance UNKNOWN

Interfaces & connectors

ac_terminal_type grid connection terminal with AC protective cover
backup_eps_terminal EPS connection terminal
battery_terminal_type supplied battery connectors (positive/negative), manual p.32
bluetooth UNKNOWN
can yes (CAN1 and CAN2 ports)
cellular optional Pocket 4G dongle
drm yes
dry_contacts OFF terminal listed in the port table
ethernet optional Pocket LAN dongle
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
protocol_notes Datasheet communication row verbatim: 'CT/Meter (optional), External control RS485, Pocket WiFi (Optional: Pocket LAN/4G), DRM'. Communication wiring uses CAT5E (RJ45).
pv_connector_type supplied PV connectors (positive/negative); brand not named in the manual
rs485 yes (external control RS485; Meter/CT port)
sunspec UNKNOWN
usb Dongle/Upgrade terminal
wifi optional Pocket WiFi dongle

Controls & display

audible_alarm UNKNOWN
buttons ESC key referenced (manual p.44)
display_type LCD panel including screen, indicators and keys (manual p.4); size not stated
leds indicators on the LCD panel (details not given in the fetched pages)
local_display True
mobile_app UNKNOWN (SolaX Cloud ecosystem via Pocket dongles)
remote_display_option UNKNOWN
status_indicators UNKNOWN
touchscreen False
web_interface UNKNOWN

Protection

afci Optional
anti_islanding yes (grid monitoring)
back_feed_current_monitoring yes
dc_injection_monitoring yes
ground_fault_protection yes (earth-fault monitoring per IEC 62109-2 clause 13.9, manual p.48)
insulation_monitoring yes (DC isolation)
integrated_breakers_fuses UNKNOWN
integrated_dc_switch True
over_current yes (AC overcurrent)
over_temperature yes
over_voltage yes (over/under voltage protection)
overvoltage_category Mains: III, Battery: II, PV: II
protection_class UNKNOWN
residual_current_monitoring yes - integrated Type-B Residual Current Monitoring Unit (RCMU)
X3-Hybrid G4 User Manual (EN) — manual pp.2-3: integrated Type-B RCMU
reverse_polarity yes (DC reverse-polarity protection)
short_circuit yes (AC short-circuit)
surge_protection DC: Type II, AC: Type II
under_voltage yes

Certifications

emc []
grid_codes ['VDE4105', 'G99', 'G98', 'AS4777', 'EN50549', 'CEI 0-21', 'IEC61727', 'PEA/MEA', 'NRS-097-2-1', 'RD1699', 'TOR']
X3-HYBRID G4 Three-phase Residential Hybrid Inverter Datasheet — datasheet certification row
other []
regional ['CE', 'TUV', 'RCM']
safety ['EN/IEC62109-1', 'EN/IEC62109-2']

Warranty & service

conditions UNKNOWN
cycle_life N/A
design_life_years UNKNOWN
extended_options_years UNKNOWN
fan_replaceable UNKNOWN
field_replaceable_parts UNKNOWN
fuse_replaceable UNKNOWN
service_intervals UNKNOWN
standard_years UNKNOWN

Documents

datasheet X3-HYBRID G4 Three-phase Residential Hybrid Inverter Datasheet rev UNKNOWN
product-page X3 HYBRID G4 product page rev UNKNOWN
user-manual X3-Hybrid G4 User Manual (EN) rev UNKNOWN

Documented compatibility

Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.

inverter_battery

SolaX Power Triple Power T-BAT-SYS-HV 5.8 (T58) COMPATIBLEofficially-verified
SolaX T-BAT-SYS-HV Datasheet

inverter_evse

go-e GmbH go-eCharger Gemini (11kW and 22kW variants) COMPATIBLEinferred-from-electrical-parameters
go-e Gemini Datasheet (open local API/Modbus TCP/MQTT) + third-party EMS tools (evcc, openWB)

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

EfficiencyMax. 98.0 %, European 97.7 %
PV wire / grid wire cross-section4-6 mm2 (PV), 5-6 mm2 (grid)
Parallel capabilityon-grid and off-grid parallel function, up to 150kW
Power consumption (night)< 40 W for standby, < 5 W for idle
Rated EPS output power / Peak EPS output power / Switchover time10 kVA / 18.0 kVA, 10 s / < 10 ms

Build a system with this product