Solis (Ginlong Technologies Co., Ltd.) S6-EH1P6K-L-PLUS
Manufacturer documented EUR (manual edition fetched is EUR V1.2) verified Sept. 2, 2026
UNKNOWN
Identity
| brand | Solis |
| category | inverters |
| ean | UNKNOWN |
| generation | S6 L-PLUS |
| manufacturer | Solis (Ginlong Technologies Co., Ltd.) |
| market_version | UNKNOWN |
| model | S6-EH1P6K-L-PLUS |
| mpn | UNKNOWN |
| product_family | S6-EH1P(3-10)K-L-PLUS (3K/3.6K/4.6K/5K/6K/8K, plus 9K/10K in the (21A) variant) |
| product_revision | UNKNOWN |
| product_status | active |
| region | EUR (manual edition fetched is EUR V1.2) |
| release_year | UNKNOWN |
| sku | UNKNOWN |
Electrical
| ac_coupling_support | UNKNOWN |
| backup_eps_output_support | true (rated backup power 6 kW; overload '2 times of rated power, 10 s') |
| battery_support | True |
| battery_type | Li-ion / Lead-acid |
| battery_voltage_class | LV |
| battery_voltage_max_v | 60 |
| battery_voltage_min_v | 40 |
| communication_can | True |
| communication_ethernet | optional (LAN module) |
| communication_rs485 | True |
| communication_wifi | optional (Wi-Fi/GPRS modules) |
| ct_support | UNKNOWN |
| generator_input_support | true ('multiple generator connection methods with auto control', official product page) |
| grid_certifications | ['NRS 097-2-1', 'IEC 62116', 'IEC 61727', '(certification list from fetched datasheet copy; region-specific variants exist)'] |
| grid_export_control | true ('Grid-tied power connection export control', official product page) |
| grid_frequency_hz | 50/60 |
| grid_voltage_v | 220/230 |
| home_assistant_integration | UNKNOWN |
| max_ac_power_kw | 6 |
| max_battery_charge_current_a | 135 |
| max_battery_charge_power_kw | UNKNOWN |
| max_battery_discharge_current_a | 135 |
| max_dc_voltage_v | 500 |
| max_input_current_per_mppt_a | 32 |
| max_parallel_units | 6 |
| max_pv_input_power_w | 12000 ('Recommended max. PV array size 12 kW'; 'Max. usable PV input power 9.6 kW' per datasheet mirror) |
| max_short_circuit_current_per_mppt_a | 40 |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| mppt_max_voltage_v | 435 |
| mppt_min_voltage_v | 90 |
| num_mppt | 2 |
| officially_supported_battery_brands | ['Pylontech', 'Dyness', 'BYD', 'BSLBATT', 'WECO', 'Pytes', 'LG Energy Solution', '(LV list; Solis Battery Matching pamphlet V2.5_202511)'] |
| parallel_support | True |
| phase_type | single-phase |
| pv_inputs_per_mppt | 2 |
| rated_ac_power_kw | 6 |
| region_variant | Global (fetched datasheet copy carries NRS/IEC certs; scribd title suggests V1.2 2024-04 LKA edition of same doc) |
| smart_meter_support | UNKNOWN (export control documented; meter model not named in fetched docs) |
| sources | [{'url': 'https://liriksolar.com/image/uploads/Solis%20S6-EH1P6K-l-PLUS%20Datasheet.pdf', 'title': 'Solis S6-EH1P-L-PLUS datasheet (distributor mirror)', 'doc_type': 'datasheet', 'publisher': 'Ginlong/Solis via Lirik Solar', 'language': 'en', 'accessed': '2026-09-01', 'confidence': 'manufacturer-documented'}, {'url': 'https://www.solisinverters.com/ph/energy_storage_inverters19/S6-EH1P(3-8)K-L-PLUS_ph.html', 'title': 'S6-EH1P(3-10)K-L-PLUS official product page', 'doc_type': 'product-page', 'publisher': 'Ginlong/Solis (official)', 'language': 'en', 'accessed': '2026-09-01', 'confidence': 'officially-verified'}, {'url': 'https://cdn.shopify.com/s/files/1/0257/3103/9284/files/Solis-Battery-Matching-GLOBAL-Pamphlet_compressed.pdf?v=1765378811', 'title': 'Solis Battery Matching GLOBAL pamphlet V2.5_202511 (mirror)', 'doc_type': 'compatibility-list', 'publisher': 'Ginlong/Solis via distributor CDN', 'revision': 'V2.5_202511', 'language': 'en', 'accessed': '2026-09-01', 'confidence': 'manufacturer-documented'}] |
| startup_voltage_v | 90 |
| sunspec_support | UNKNOWN |
| topology | hybrid |
Physical / mechanical
| bracket_dimensions_mm | 407.5 x 358 x 322 for (3-6)K (manual Fig. 3.7, p.12) |
| cable_entry_positions | UNKNOWN |
| cable_gland_sizes | COM1 and COM2: 4-hole watertight cable glands, 6 mm hole diameter; COM3: 6-hole watertight cable gland, 2 mm hole diameter (manual p.22) |
| depth_mm | 253 |
| enclosure_material | UNKNOWN |
| height_mm | 560 |
| housing_color | UNKNOWN |
| mounting_bolt_size | expansion bolt, 4 supplied (manual p.04 packing list); thread size not stated |
| mounting_hole_diameter_mm |
6.8 (manual Fig. 3.7, p.12, 'PHI 6.8', '3-OB11*6.8')
Solis_Manual_S6-EH1P8K-L-PLUS_EUR_V1,2(20251030) - User Manual for S6 Series Hybrid Inverter, covering S6-EH1P(3-8)K-L-PLUS — Figure 3.7, p.12
|
| mounting_hole_spacing_mm |
177 and 222 (manual Fig. 3.7, p.12)
Solis_Manual_S6-EH1P8K-L-PLUS_EUR_V1,2(20251030) - User Manual for S6 Series Hybrid Inverter, covering S6-EH1P(3-8)K-L-PLUS — Figure 3.7, p.12
|
| mounting_plate_dimensions_mm | back plate: 407.5 wide x 358 high for the (3-6)K (360 high for the 8K), 322 deep (manual Fig. 3.7, p.12) |
| mounting_type | ['wall'] |
| screw_sizes | M4 (PE OT terminal); battery OT terminal R38-8 for (3-6)K (manual p.14, p.18) |
| shipping_weight_kg | UNKNOWN |
| terminal_locations | DC switch, PV module input, battery connection (BAT+/BAT-), Grid, Backup, Gen, COM port (manual p.13) |
| torque_specs |
AC grid terminal 4-5 N.m (C10-12, 8-6 AWG); AC backup / AC gen 4-5 N.m (C6-12, 10-6 AWG) (manual p.19); ground / PE OT terminal M4 at 2 N.m (manual p.14); cable glands 4-5 N.m (manual p.19)
Solis_Manual_S6-EH1P8K-L-PLUS_EUR_V1,2(20251030) - User Manual for S6 Series Hybrid Inverter, covering S6-EH1P(3-8)K-L-PLUS — p.19 AC wiring table; p.14 PE terminal
|
| weight_kg | 23.5 |
| width_mm | 335 |
Installation
| altitude_derating_note | 'Max. operation altitude 3000m' |
| clearance_bottom_mm | 500 |
| clearance_front_mm | 300 |
| clearance_left_mm | 150 |
| clearance_note | manual Fig. 3.5, p.11: top >=500 mm, sides >=150 mm, front >=300 mm, bottom >=800 mm above ground. p.12: '...if there is a heat source device such as the battery cabinet under the inverter, it is recommended to install it at a distance of not less than 800mm. If there is no heat source, the minimum spacing at the bottom is 500mm.' p.09: 'A minimum clearance of 150mm should be kept between each inverter and all other mounted equipment.' |
| clearance_right_mm | 150 |
| clearance_top_mm |
500
Solis_Manual_S6-EH1P8K-L-PLUS_EUR_V1,2(20251030) - User Manual for S6 Series Hybrid Inverter, covering S6-EH1P(3-8)K-L-PLUS — Figure 3.5, p.11
|
| indoor_outdoor | indoor and outdoor (IP66; 'Environmental category: Indoor and outdoor') |
| max_installation_altitude_m | 3000 |
| min_distance_between_units_mm | 150 |
| min_height_above_ground_mm | 800 |
| mounting_orientation |
vertical, maximum incline +/-5 degrees (manual p.11-12); also stated as '90 degrees, or backwards less than or equal to 15 degrees from 90 degrees straight up' (p.09)
Solis_Manual_S6-EH1P8K-L-PLUS_EUR_V1,2(20251030) - User Manual for S6 Series Hybrid Inverter, covering S6-EH1P(3-8)K-L-PLUS — p.11, 'The inverter must be mounted vertically with a maximum incline of +/- 5 degree'
|
| orientation_allowed | ['vertical'] |
| orientation_forbidden | ['incline beyond +/-5 degrees', "two units installed in one vertical line one above the other ('It is prohibited to install two units in one line up and down', manual p.12)"] |
| surface_requirements | 'Load bearing surface: Made of non-inflammable materials', 'Max. load bearing capacity >= 4 times of inverter weight' (manual p.09) |
| two_person_lift_required | UNKNOWN |
Environment
| cooling_method | natural convection (3-6K models; the 8K uses 'Intelligent cooling') |
| corrosion_class | UNKNOWN |
| fan_replaceable | n/a for the 6K (natural convection) |
| ik_rating | UNKNOWN |
| ip_rating |
IP66
Solis_Manual_S6-EH1P8K-L-PLUS_EUR_V1,2(20251030) - User Manual for S6 Series Hybrid Inverter, covering S6-EH1P(3-8)K-L-PLUS — General Data spec table, p.64, 'Ingress protection IP66'
|
| max_altitude_m | 3000 |
| nema_rating | UNKNOWN |
| noise_level_db | <35 dB(A) ('Single inverter noise is less than 35 dB(A)' - manual p.19) |
| operating_temperature_c | -40 to +60 |
| pollution_degree | 3 |
| relative_humidity | 0-95% |
| storage_temperature_c | UNKNOWN |
Interfaces & connectors
| ac_terminal_type | terminal block |
| backup_eps_terminal | yes - 'Backup' AC output to subpanel; backup switch time <4 ms |
| battery_terminal_type | terminal block / OT terminal R38-8, recommended 2 AWG for (3-6)K (manual p.18) |
| bluetooth | yes ('Display: LCD indicator & Bluetooth + APP') |
| can | yes - BMS terminal, pin 4 CAN-H (blue), pin 5 CAN-L (blue/white) (manual p.24) |
| cellular | optional GPRS module |
| cloud_api | SolisCloud |
| ct_interface | CT terminal: BLACK wire to pin 2, WHITE wire to pin 1 of the terminal block (manual p.28-29); CT supplied |
| drm_interface | yes - DRM / remote-shutdown logic interface, pin 5 Switch_input1, pin 6 Switch_input2 (manual p.26-27) |
| dry_contacts | 12-pin terminal block on COM3: pins 1-2 CT, pins 3-4 generator start-stop signal, pins 9-10 heat-pump control signal (manual p.28-29) |
| ethernet | optional LAN module |
| generator_start_contact | yes - 12-pin block pins 3-4 (manual p.28-29) |
| generator_terminal | yes - 'Gen' AC generator connection (manual p.13) |
| local_api | UNKNOWN |
| meter_interface | meter RS485 terminal: pin 1 RS485A (orange/white), pin 2 RS485B (orange) (manual p.25) |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| parallel_port | yes - parallel communication cable supplied; up to 6 units |
| protocol_notes | COM: USB for Solis data logger; COM1 and COM2: RJ45 (4-hole watertight glands); COM3: 12-pin terminal block (6-hole gland) (manual p.22). |
| pv_connector_type | MC4 plug (PV port) |
| rapid_shutdown_interface | UNKNOWN |
| relay_outputs | UNKNOWN |
| rs485 | yes (BMS/meter/3rd-party; 3rd-party RS485 on pin 5 = RS485A, pin 4 = RS485B, manual p.28) |
| smart_load_output | heat-pump control signal on 12-pin block pins 9-10 (manual p.28-29) |
| sunspec | UNKNOWN |
| usb | yes - COM port, USB, used for the Solis data logger (manual p.22) |
| wifi | optional Wi-Fi stick (WLan Stick supplied per packing list) |
| zigbee | UNKNOWN |
Controls & display
| audible_alarm | UNKNOWN |
| buttons | 4 front-panel keys: ESC, UP, DOWN, ENTER (manual p.34) |
| display_type |
7-inch colour LCD screen
Solis_Manual_S6-EH1P8K-L-PLUS_EUR_V1,2(20251030) - User Manual for S6 Series Hybrid Inverter, covering S6-EH1P(3-8)K-L-PLUS — p.03 and p.33, '7-Inch colorful LCD screen'
|
| leds | 3 - POWER, OPERATION, ALARM (red / green / orange) (manual p.33) |
| local_display | True |
| mobile_app | SolisCloud (manual p.35, p.47) |
| touchscreen | UNKNOWN |
| web_interface | SolisCloud |
Protection
| afci | optional - 'Integrated AFCI: Optional' (spec table); 'Safety protection with integrated AFCI function, which actively detects arc faults in the PV Array' (manual p.03) |
| anti_islanding | UNKNOWN |
| ground_fault_protection | yes - 'Ground fault monitoring: Yes' |
| insulation_monitoring | UNKNOWN |
| integrated_dc_switch | yes - 'DC Switch' on the unit (manual p.13) |
| over_temperature | UNKNOWN |
| overvoltage_category | II (PV and BAT), III (MAINS and BACKUP and GEN) |
| protection_class | I |
| recommended_rcd | leakage current protector Type C, Icc >= 20 kA (manual p.19) |
| residual_current_monitoring | yes - 'Residual current monitoring: Yes' |
| reverse_polarity | yes - 'DC reverse polarity protection: Yes' |
| surge_protection | UNKNOWN |
Certifications
| emc | ['EN 61000-6-2', 'EN 61000-6-3'] |
| grid_codes | ['NRS 097-2-1', 'IEC 62116', 'IEC 61727', 'IEC 60068', 'G98', 'IEC 61683', 'EN 50530', 'MEA', 'PEA', 'NBR 16149', 'NBR 16150'] |
| other | [] |
| regional | [] |
| safety | ['IEC/EN 62109-1', 'IEC/EN 62109-2'] |
Warranty & service
| conditions | 'Warranty: 5 years standard (extend to 20 years)' - manual spec table |
| design_life_years | UNKNOWN |
| extended_options_years | [20] |
| field_replaceable_parts | UNKNOWN |
| service_intervals | UNKNOWN |
| standard_years |
5
Solis_Manual_S6-EH1P8K-L-PLUS_EUR_V1,2(20251030) - User Manual for S6 Series Hybrid Inverter, covering S6-EH1P(3-8)K-L-PLUS — Features spec table, 'Warranty: 5 years standard (extend to 20 years)'
|
Documents
user-manual
Solis_Manual_S6-EH1P8K-L-PLUS_EUR_V1,2(20251030) - User Manual for S6 Series Hybrid Inverter, covering S6-EH1P(3-8)K-L-PLUS
rev V1.2 (20251030)
Documented compatibility
Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.
inverter_battery
Pylontech US3000C
COMPATIBLEmanufacturer-documented
Solis Battery Matching GLOBAL pamphlet V2.5_202511 (distributor-CDN mirror of official list)
BSLBATT B-LFP48-100E (3U Server Rack Battery)
COMPATIBLEmanufacturer-documented
Solis Battery Matching GLOBAL pamphlet V2.5_202511 (distributor-CDN mirror of official list)
WECO 5K3-XP
COMPATIBLEmanufacturer-documented
Solis Battery Matching GLOBAL pamphlet V2.5_202511 (distributor-CDN mirror of official list)
Pytes E-Box 48100R
COMPATIBLEmanufacturer-documented
Solis Battery Matching GLOBAL pamphlet V2.5_202511 (distributor-CDN mirror of official list)
BYD Battery-Box Premium LVS (4.0-24.0 family, 16.0 kWh representative)
COMPATIBLEmanufacturer-documented
Solis Battery Matching GLOBAL pamphlet V2.5_202511 (distributor-CDN mirror of official list)
Dyness Powerbox G2
COMPATIBLEmanufacturer-documented
Solis Battery Matching GLOBAL pamphlet V2.5_202511 (distributor-CDN mirror of official list)
Pytes V5 / V5-alpha (printed as V5° / V5°α)
COMPATIBLEofficially-verified
Pytes Inverter Compatibility List V.20230819, https://www.pytesess.com/ueditor/php/upload/file/20240705/1720170604646137.pdf (fetched 2026-09-01)
Dyness A48100
COMPATIBLEmanufacturer-documented
Dyness A48100 User Manual section 2.3.1 DIP master-setting table, https://www.ienergy-us.com/uploads/files/A48100%C2%A0User%C2%A0Manual.pdf (fetched 2026-09-01)
BSLBATT B-LFP48-200E (19-inch rack battery, 10.24 kWh)
COMPATIBLEmanufacturer-documented
BSLBATT B-LFP48 Rack Battery Pack User Manual V2.7 CAN/RS485 protocol tables, https://bslbatt.com/wp-content/uploads/2024/09/B-LFP48-User-Manual-V2.7-Rack-Battery-Pack.pdf (fetched 2026-09-01)
Recorded conflicts
efficiency_max_pct Review required
96.2 — existing record source (distributor datasheet mirror)
96.1 — Solis EUR manual V1.2, 6K spec table: 'Max. efficiency: 96.1%'; 'BAT discharged to AC Max. efficiency: 96.2%'
the 96.2% figure is the battery-discharge-to-AC efficiency row, not the overall max efficiency
pv_inputs_per_mppt Review required
2 — existing record (distributor datasheet mirror)
1 (2 MPPT / 2 strings total) — Solis EUR manual V1.2: 'MPPT number/Max input strings number: 2/2'
variant or revision difference; the manual's 2/2 means one string per MPPT
max_pv_input_power_w Review required
12000 — liriksolar.com datasheet mirror: 'Recommended max. PV array size 12 kW' / 'Max. usable PV input power 9.6 kW'
9600 — Solis EUR manual V1.2, 6K spec table: 'Max Usable PV Input Power: 9600W'
'recommended array size' vs 'max usable PV input power' are different rows; the manual quotes only the usable figure
max_short_circuit_current_per_mppt_a Review required
40 — liriksolar.com datasheet mirror: 'Max. short circuit current: 40 A / 40 A'
20 — Solis EUR manual V1.2, 6K spec table: 'Max. short circuit current: 20A/20A'
same variant/revision divergence as the input-current conflict
max_input_current_per_mppt_a Review required
32 — liriksolar.com datasheet mirror (existing record source): 'Max. input current: 32 A / 32 A'
16 — Solis_Manual_S6-EH1P8K-L-PLUS_EUR_V1.2(20251030), 6K spec table: 'Max. input current: 16A/16A'
different hardware/market variant or document revision - the family also has an explicit (21A) variant; the fetched EUR manual V1.2 is newer than the undated distributor datasheet mirror
backup_switch_time Review required
< 4 ms — datasheet mirror: 'Switch time < 4 ms'
< 10 ms — official product page: 'Seamless on/off-grid switching in under 10ms'
marketing rounding vs datasheet spec / doc revision
max_input_current_per_mppt_a Review required
32 — datasheet mirror: '32 A / 32 A' per MPPT (2 strings per MPPT)
up to 21 — official product page summary: 'up to 21 A per MPPT'
product-page figure likely refers to the per-string current of the (9-10)K '(21A)' variants; datasheet per-MPPT total is 32A - model-suffix confusion
efficiency_max_pct Review required
96.2 — existing record source (distributor datasheet mirror)
96.1 — Solis EUR manual V1.2, 6K spec table: 'Max. efficiency: 96.1%'; 'BAT discharged to AC Max. efficiency: 96.2%'
the 96.2% figure is the battery-discharge-to-AC efficiency row, not the overall max efficiency
pv_inputs_per_mppt Review required
2 — existing record (distributor datasheet mirror)
1 (2 MPPT / 2 strings total) — Solis EUR manual V1.2: 'MPPT number/Max input strings number: 2/2'
variant or revision difference; the manual's 2/2 means one string per MPPT
max_pv_input_power_w Review required
12000 — liriksolar.com datasheet mirror: 'Recommended max. PV array size 12 kW' / 'Max. usable PV input power 9.6 kW'
9600 — Solis EUR manual V1.2, 6K spec table: 'Max Usable PV Input Power: 9600W'
'recommended array size' vs 'max usable PV input power' are different rows; the manual quotes only the usable figure
max_short_circuit_current_per_mppt_a Review required
40 — liriksolar.com datasheet mirror: 'Max. short circuit current: 40 A / 40 A'
20 — Solis EUR manual V1.2, 6K spec table: 'Max. short circuit current: 20A/20A'
same variant/revision divergence as the input-current conflict
backup_switch_time Review required
< 4 ms — datasheet mirror: 'Switch time < 4 ms'
< 10 ms — official product page: 'Seamless on/off-grid switching in under 10ms'
marketing rounding vs datasheet spec / doc revision
max_input_current_per_mppt_a Review required
32 — datasheet mirror: '32 A / 32 A' per MPPT (2 strings per MPPT)
up to 21 — official product page summary: 'up to 21 A per MPPT'
product-page figure likely refers to the per-string current of the (9-10)K '(21A)' variants; datasheet per-MPPT total is 32A - model-suffix confusion
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Back-up switch time | <4ms |
| DC (battery) breaker recommended size | 300A |
| Heat pump control signal | 12-pin terminal block pins 9-10 |
| Inrush current | 217A 10us |
| Max. AC Passthrough current | 40.0 A / 39.0 A |
| Maximum output fault current | 80 A |
| Prohibited layout | It is prohibited to install two units in one line up and down |
| Recommended AC breaker | two-pole 100A, leakage current protector recommended Type C, Icc>=20KA |
| Topology | High frequency insolation (for battery) |