Solis (Ginlong Technologies Co., Ltd.) S6-GR1P5K
Manufacturer documented EUR (manual edition fetched is FN EUR V1.2) verified Sept. 2, 2026
Identity
| brand | Solis |
| category | inverters |
| ean | UNKNOWN |
| generation | S6 |
| manufacturer | Solis (Ginlong Technologies Co., Ltd.) |
| market_version | UNKNOWN |
| model | S6-GR1P5K |
| mpn | UNKNOWN |
| product_family | S6-GR1P(2.5-6)K (2.5K / 3K / 3.6K / 4K / 4.6K / 5K / 6K) |
| product_revision | UNKNOWN |
| product_status | superseded |
| product_status_detail | superseded (the current Solis global site lists only the S6-GR1P(2.5-6)K-S variant; no live official product page for the non-S S6-GR1P5K was found on 2026-09-02) |
| region | EUR (manual edition fetched is FN EUR V1.2) |
| release_year | UNKNOWN |
| sku | UNKNOWN |
Electrical
| ac_coupling_support | UNKNOWN |
| backup_eps_output_support | False |
| battery_support | False |
| battery_type | N/A |
| battery_voltage_class | N/A |
| battery_voltage_max_v | N/A |
| battery_voltage_min_v | N/A |
| communication_can | False |
| communication_ethernet | UNKNOWN |
| communication_rs485 | True |
| communication_wifi | optional (DLS-W WiFi datalogger; DLS-G GPRS) |
| ct_support | UNKNOWN |
| generator_input_support | False |
| grid_certifications | ['IEC 61683', 'IEC 60068', 'IEC 61727', 'IEC 62116', 'EN 50530', 'IS 16169 / IS 16221 (BIS)', '(fetched copy appears to be IND/global edition; UK -DC variant lists G98/G99)'] |
| grid_export_control | UNKNOWN |
| grid_frequency_hz | 50/60 |
| grid_voltage_v | 1/N/PE, 220/230 |
| home_assistant_integration | UNKNOWN |
| max_ac_power_kw | 5 (Max. apparent output power 5 kVA per fetched datasheet; but 'Max. output current 25.0A' in same doc implies 5.5 kVA-class - see notes) |
| max_battery_charge_current_a | N/A |
| max_battery_charge_power_kw | N/A |
| max_battery_discharge_current_a | N/A |
| max_dc_voltage_v | 600 |
| max_input_current_per_mppt_a | 14 |
| max_parallel_units | UNKNOWN |
| max_pv_input_power_w | 7500 |
| max_short_circuit_current_per_mppt_a | 22 |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| mppt_max_voltage_v | 520 |
| mppt_min_voltage_v | 90 |
| num_mppt | 2 |
| officially_supported_battery_brands | N/A |
| parallel_support | UNKNOWN |
| phase_type | single-phase |
| pv_inputs_per_mppt | 1 |
| pv_oversizing_ratio | 1.5 (7.5 kW recommended max PV on 5 kW) |
| rated_ac_power_kw | 5 |
| region_variant | IND/Global datasheet edition (BIS certs); UK variant S6-GR1P5K-DC differs (90-550V MPPT, 16A input, 22.7A output) |
| smart_meter_support | UNKNOWN |
| sources | [{'url': 'https://green-energy.bg/wp-content/uploads/2023/09/data-sheet-solis-s6-gr1p5k.pdf', 'title': 'Solis S6-GR1P(4-5)K datasheet (distributor mirror)', 'doc_type': 'datasheet', 'publisher': 'Ginlong/Solis via Green Energy BG', 'doc_date': '2023-09 (upload path)', 'language': 'en', 'accessed': '2026-09-01', 'confidence': 'manufacturer-documented'}, {'url': 'https://voltaconsolar.com/products/solis-5kw-grid-tied-s6-gr1p5k-dc', 'title': 'Solis S6-GR1P5K-DC product page (UK distributor)', 'doc_type': 'distributor-page', 'publisher': 'Voltacon', 'language': 'en', 'region': 'UK', 'accessed': '2026-09-01', 'confidence': 'distributor-verified'}] |
| startup_voltage_v | 120 |
| sunspec_support | UNKNOWN |
| topology | grid-tie |
Physical / mechanical
| bracket_dimensions_mm | UNKNOWN |
| cable_entry_positions | UNKNOWN |
| cable_gland_sizes | UNKNOWN |
| depth_mm | 160 |
| dimension_note | '310W*543H*160D (mm)' - manual p.53; datasheet mirror prints '310*543*160 mm' |
| enclosure_material | UNKNOWN |
| height_mm | 543 |
| housing_color | UNKNOWN |
| mounting_bolt_size | UNKNOWN (not stated in manual V1.2) |
| mounting_hole_diameter_mm | UNKNOWN |
| mounting_hole_spacing_mm | UNKNOWN |
| mounting_plate_dimensions_mm | UNKNOWN (Figure 4.5 p.11 shows a mounting layout but the extracted numbers - 300/300/300 and 500/500 - could not be assigned to specific dimensions with confidence) |
| mounting_type | ['wall'] |
| screw_sizes | UNKNOWN |
| shipping_weight_kg | UNKNOWN |
| terminal_locations | DC+, DC-, GRID, DC SWITCH, COM (manual p.13) |
| torque_specs |
AC terminals 0.8 N.m; AC connector nut 2.5 +/- 0.5 N.m; external ground 2 N.m (manual p.16-17)
Installation and Operation Manual - Solis S6 Single Phase Inverter, S6-GR1P(2,5-6)K FN EUR V1.2 — p.16-17, AC terminal 'Torque 0.8N.m', nut '2.5+/-0.5 N.m', external ground '2N.m'
|
| weight_kg |
12
Installation and Operation Manual - Solis S6 Single Phase Inverter, S6-GR1P(2,5-6)K FN EUR V1.2 — p.53 spec table, '12kg'
|
| width_mm |
310
Installation and Operation Manual - Solis S6 Single Phase Inverter, S6-GR1P(2,5-6)K FN EUR V1.2 — p.53 spec table, '310W*543H*160D (mm)'
|
Installation
| clearance_bottom_mm | 305 (same source) |
| clearance_front_mm | UNKNOWN |
| clearance_left_mm | 305 ('minimum 12 inches clearance should be kept between each inverter or other object' - manual p.10; 12 in = 304.8 mm) |
| clearance_right_mm | 305 (same source) |
| clearance_top_mm | 305 (same source) |
| indoor_outdoor | indoor and outdoor (IP66) |
| max_installation_altitude_m | 4000 |
| min_distance_between_units_mm | 305 (12 inches, manual p.10) |
| min_height_above_ground_mm |
508 ('The bottom of the inverter should be 20 inches clearance to the ground' - manual p.10; 20 in = 508 mm)
Installation and Operation Manual - Solis S6 Single Phase Inverter, S6-GR1P(2,5-6)K FN EUR V1.2 — p.10, 'The bottom of the inverter should be 20inchs clearance to the ground'
|
| mounting_orientation |
vertical, maximum incline +/-5 degrees (manual p.10-11)
Installation and Operation Manual - Solis S6 Single Phase Inverter, S6-GR1P(2,5-6)K FN EUR V1.2 — p.10-11, 'The inverter shall be mounted vertically' with 'maximum incline of +/-5 degrees'
|
| orientation_allowed | ['vertical'] |
| orientation_forbidden | UNKNOWN |
| surface_requirements | 'a wall or strong structure capable of bearing the weight' (manual p.10-11) |
Environment
| cooling_method | natural convection |
| corrosion_class | UNKNOWN |
| fan_replaceable | n/a (fanless) |
| ik_rating | UNKNOWN |
| ip_rating |
IP66
Installation and Operation Manual - Solis S6 Single Phase Inverter, S6-GR1P(2,5-6)K FN EUR V1.2 — p.49/p.53, 'IP66'
|
| max_altitude_m | 4000 |
| nema_rating | UNKNOWN |
| noise_level_db | <20 dB(A) |
| operating_temperature_c | -25 to +60 |
| pollution_degree | UNKNOWN |
| relative_humidity | 0-100% |
| storage_temperature_c | UNKNOWN |
Interfaces & connectors
| ac_terminal_type | quick connection plug / AC connector (supplied) |
| battery_terminal_type | N/A (grid-tie inverter) |
| bluetooth | UNKNOWN |
| can | no (not listed) |
| cellular | optional - DLS-G GPRS datalogger stick |
| drm_interface | yes - DRM logic interface on the RJ45: Pin 5 Switch_input1, Pin 6 Switch_input2 (manual p.24) |
| ethernet | UNKNOWN |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| protocol_notes | COM port carries RS485 and the DRM logic interface (manual p.13, p.24). |
| pv_connector_type | MC4 connector |
| rs485 | yes |
| sunspec | UNKNOWN |
| usb | UNKNOWN |
| wifi | optional - DLS-W Wi-Fi datalogger stick |
| zigbee | UNKNOWN |
Controls & display
| audible_alarm | UNKNOWN |
| buttons | 4 - ESC, UP, DOWN, ENTER (manual p.8-9) |
| display_type | two-line LCD (manual p.8-9); datasheet mirror prints 'LCD' |
| leds | 3 - POWER, OPERATION, ALARM (manual p.8-9) |
| local_display | True |
| mobile_app | UNKNOWN (not named in the fetched manual V1.2) |
| touchscreen | False |
| web_interface | UNKNOWN |
Protection
| afci | yes - 'Yes (1)' (datasheet); arc-fault detection described in manual p.6-7 |
| anti_islanding | yes |
| insulation_monitoring | UNKNOWN |
| integrated_dc_switch | True |
| over_temperature | yes |
| overvoltage_category | UNKNOWN |
| protection_class | UNKNOWN |
| residual_current_monitoring | leakage current protection described (manual p.6-7); explicit RCMU row ABSENT from the datasheet |
| reverse_polarity | yes |
| surge_protection | UNKNOWN (no SPD type row on the fetched datasheet) |
Certifications
| emc | ['IEC 61000-6-2', 'IEC 61000-6-3'] |
| grid_codes | ['IEC 61683', 'IEC 60068', 'IEC 61727', 'IEC 62116', 'EN 50530', 'IS 16169 (BIS)', 'IS 16221 (BIS)'] |
| other | [] |
| regional | [] |
| safety | ['IEC 62109-1', 'IEC 62109-2'] |
Warranty & service
| conditions | UNKNOWN |
| design_life_years | UNKNOWN |
| extended_options_years | UNKNOWN |
| field_replaceable_parts | UNKNOWN |
| service_intervals | UNKNOWN |
| standard_years | UNKNOWN (row ABSENT from the fetched datasheet and manual) |
Documents
installation-manual
Installation and Operation Manual - Solis S6 Single Phase Inverter, S6-GR1P(2,5-6)K FN EUR V1.2
rev V1.2 (20221116)
Recorded conflicts
max_input_current_per_mppt_a Review required
14 — green-energy.bg datasheet mirror: 14 A per MPPT
16 — Voltacon S6-GR1P5K-DC page: '16 A / 16 A'
regional/hardware variant (-DC UK model) or doc revision
mppt_max_voltage_v Review required
520 — green-energy.bg datasheet mirror: 'MPPT voltage range 90-520 V'
550 — Voltacon S6-GR1P5K-DC page: 'MPPT Voltage Range 90-550 V'
regional/hardware variant (-DC UK model) or doc revision
max_input_current_per_mppt_a Review required
14 — green-energy.bg datasheet mirror: 14 A per MPPT
16 — Voltacon S6-GR1P5K-DC page: '16 A / 16 A'
regional/hardware variant (-DC UK model) or doc revision
mppt_max_voltage_v Review required
520 — green-energy.bg datasheet mirror: 'MPPT voltage range 90-520 V'
550 — Voltacon S6-GR1P5K-DC page: 'MPPT Voltage Range 90-550 V'
regional/hardware variant (-DC UK model) or doc revision
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Max input current (manual p.53 spec table) | 120A |
| identity.product_status | superseded (the current Solis global site lists only the S6-GR1P(2.5-6)K-S variant; no live official product page for the non-S S6-GR1P5K was found on 2026-09-02) |