ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseInverters

Sungrow SG320HX

Official manufacturer EU / GL verified Sept. 3, 2026

Identity

category inverters
ean UNKNOWN
generation HX (1500 Vdc utility string platform)
grid_type 3 / PE, 800 V (no neutral) - designed for an MV step-up transformer
hardware_revision UNKNOWN
legacy_name UNKNOWN
manufacturer Sungrow
manufacturer_legal_entity Sungrow Power Supply Co., Ltd.
market_version UNKNOWN
model SG320HX
mpn UNKNOWN
order_code UNKNOWN
phase_configuration three-phase (3 / PE, no neutral)
product_family SG285/320/333/350HX (HX utility-scale 1500 Vdc string inverter)
product_status active
product_status_detail active - listed on the official 2026 sungrowpower.com string-inverter index as 'SG320/350HX (320/350kW)'; a separate 'SG320/350HX-20' listing also exists, which is a different generation
product_status_evidence official product index fetched 2026-09-03
region EU / GL
release_year UNKNOWN
sku UNKNOWN
subcategory grid-tied PV string inverter (utility-scale, 1500 Vdc, no battery interface)
topology transformerless (no galvanic isolation)
variant_note Do NOT collapse with SG320HX-20 (a separate listed product) or with the US-market SG350HX-US / SG200HX-US. The MPPT count is order-configurable: 12 MPPTs at 40 A each, or optionally 16 MPPTs at 30 A each - these are different DC machines and should be treated as configuration variants.

Electrical

dc_ac_ratio UNKNOWN
european_efficiency_pct 98.8
grid_frequency_range 45 Hz - 55 Hz / 57 Hz - 63 Hz
max_ac_power_w 352000
max_apparent_power_va 352000
max_dc_short_circuit_current_total_a UNKNOWN
max_dc_voltage_v 1500
max_efficiency_pct 99.02
max_input_current_per_input_a UNKNOWN
max_input_current_per_mppt_a 40 A (12-MPPT configuration); 30 A (optional 16-MPPT configuration)
max_input_current_total_a UNKNOWN
max_output_current_a 254
max_pv_input_power_w UNKNOWN
max_short_circuit_current_per_mppt_a 60
min_operating_voltage_v 500
mppt_voltage_max_v 1500
mppt_voltage_min_v 500
mppt_voltage_range_for_nominal_power UNKNOWN
night_power_consumption < 6 W
nominal_dc_voltage_v 1080
nominal_frequency 50 Hz / 60 Hz
nominal_voltage 3 / PE, 800 V
num_mppt 12 (optional configuration: 16)
num_pv_inputs 24 (12 MPPTs x 2 strings); the 16-MPPT option changes this - not stated in the fetched extraction
oversizing_guidance UNKNOWN
power_factor_range > 0.99 default; 0.8 leading - 0.8 lagging
rated_ac_power_w 352 kVA @ 30 C / 320 kVA @ 40 C / 295 kVA @ 50 C (temperature-derated)
rated_output_current_a UNKNOWN
recommended_pv_power_w UNKNOWN
startup_voltage_v 550
string_rules 12 independent MPPTs with 2 strings each at 40 A per MPPT; optionally 16 MPPTs at 30 A per MPPT
strings_per_mppt 2
thd < 3 % at nominal power
voltage_range 640 V - 920 V

Physical / mechanical

cooling smart forced air cooling
dimensions_mm 1136 mm * 870 mm * 361 mm
enclosure_material UNKNOWN
mounting_type ['UNKNOWN']
weight_kg <= 116

Installation

ac_connector OT / DT terminal (max. 400 mm2)
dc_connector MC4-Evo2 (max. 6 mm2, optional 10 mm2)
indoor_outdoor outdoor (IP66)
max_installation_altitude_m 4000 m
mounting_orientation UNKNOWN

Environment

cooling smart forced air cooling
corrosion_class C5
fan_replaceable UNKNOWN
ip_rating IP66
max_altitude_m 4000 m
night_power_consumption < 6 W
noise_db UNKNOWN
operating_temperature -30 C to 60 C
relative_humidity UNKNOWN

Interfaces & connectors

bluetooth yes (Bluetooth + APP)
can none documented
communication_label RS485 / PLC
display LED, Bluetooth + APP
ethernet not documented in the fetched datasheet
isolarcloud_dependency iSolarCloud used for plant monitoring; no local-operation dependency stated
local_communication RS485 / PLC
logger_support NOT_LISTED in Compatibility List 4.3
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
plc yes (power line communication)
register_map_availability UNKNOWN
rs485 yes
wifi not documented
winet_support NOT_LISTED - the Compatibility List 4.3 WiNet rows cover SGxxRS / SGxxRT / SGxxCX only

Protection

afci not stated in the fetched HX datasheet protection row - UNKNOWN
anti_islanding yes
dc_reverse_polarity yes (DC reverse connection protection)
dc_switch yes (DC and AC switches)
grid_protection grid monitoring; LVRT, HVRT, active and reactive power control, power ramp rate control, Q-U control, P-f control
insulation_monitoring ground fault monitoring yes; PV string current monitoring yes
pid anti-PID capability
q_at_night yes
rcmu leakage current protection yes
spd Type II DC and AC surge protection

Certifications

grid_codes ['IEC 62109', 'IEC 61727', 'IEC 62116', 'IEC 60068', 'IEC 61683', 'EN 50549-1/2', 'UNE 206007-1:2013', 'UTE C15-712-1:2013']

Warranty & service

extension_options UNKNOWN
note no warranty statement appears in the fetched datasheet extraction
standard_warranty UNKNOWN

Documents

compatibility-list Sungrow Compatibility List Public 2026 (Version 4.3) rev 4.3
datasheet SG320HX Datasheet V17 EN rev Version 17
product-page SG320/350HX official product page rev UNKNOWN
product-page Sungrow string inverter product index (official website) rev UNKNOWN

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

identity.product_statusactive - listed on the official 2026 sungrowpower.com string-inverter index as 'SG320/350HX (320/350kW)'; a separate 'SG320/350HX-20' listing also exists, which is a different generation
manufacturer_legal_entity_as_printedSungrow Power Supply Co., Ltd.

Build a system with this product