ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseInverters

Sungrow SG350HX

Official manufacturer EU / GL verified Sept. 3, 2026

Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.

Identity

category inverters
ean UNKNOWN
generation HX (1500 Vdc utility string platform)
grid_type 3 / PE, 800 V (no neutral)
hardware_revision UNKNOWN
legacy_name UNKNOWN
manufacturer Sungrow
manufacturer_legal_entity Sungrow Power Supply Co., Ltd.
market_version UNKNOWN
model SG350HX
mpn UNKNOWN
order_code UNKNOWN
phase_configuration three-phase (3 / PE, no neutral)
product_family SG285/320/333/350HX (HX utility-scale 1500 Vdc string inverter)
product_status active
product_status_detail active - listed on the official 2026 sungrowpower.com string-inverter index as 'SG320/350HX (320/350kW)'; datasheet Version 23 is dated 2025-06-17
product_status_evidence official product index fetched 2026-09-03
region EU / GL
release_year UNKNOWN
sku UNKNOWN
subcategory grid-tied PV string inverter (utility-scale, 1500 Vdc, no battery interface)
topology transformerless (no galvanic isolation)
variant_note Distinct from SG350HX-20 and from the US-market SG350HX-US, both separately listed on the official index. MPPT count is order-configurable (12 x 40 A, or optionally 16 x 30 A).

Electrical

dc_ac_ratio UNKNOWN
european_efficiency_pct 98.8
grid_frequency_range 45 Hz - 55 Hz / 55 Hz - 65 Hz
max_ac_power_w UNKNOWN - see data_conflicts
max_apparent_power_va UNKNOWN - see data_conflicts
max_dc_short_circuit_current_total_a UNKNOWN
max_dc_voltage_v 1500
max_efficiency_pct 99.02
max_input_current_per_input_a UNKNOWN
max_input_current_per_mppt_a 40 A (12-MPPT configuration); 30 A (optional 16-MPPT configuration)
max_input_current_total_a 480 A stated as '12 * 40 A' (optional: '16 * 30 A')
max_output_current_a UNKNOWN - see data_conflicts (the extraction returned 254 A, identical to the SG320HX)
max_pv_input_power_w UNKNOWN
max_short_circuit_current_per_mppt_a 60
min_operating_voltage_v 500
mppt_voltage_max_v 1500
mppt_voltage_min_v 500
mppt_voltage_range_for_nominal_power UNKNOWN
night_power_consumption < 6 W
nominal_dc_voltage_v 1080
nominal_frequency 50 Hz / 60 Hz
nominal_voltage 3 / PE, 800 V
num_mppt 12 (optional configuration: 16)
num_pv_inputs 24 (12 MPPTs x 2 strings) in the standard configuration
oversizing_guidance UNKNOWN
power_factor_range > 0.99 default; 0.8 leading - 0.8 lagging
rated_ac_power_w UNKNOWN - see data_conflicts. The product page headline says '320/350 kW' for the SG320/350HX pair, but the V23 datasheet's AC-output-power line came back with the SG320HX temperature-derating string, so the SG350HX rated figure is not safely established.
rated_output_current_a UNKNOWN - see data_conflicts (the extraction returned 231 A)
recommended_pv_power_w UNKNOWN
startup_voltage_v 550
string_rules 12 independent MPPTs, 2 strings per MPPT, 40 A per MPPT; optionally 16 MPPTs at 30 A
strings_per_mppt 2
thd < 3 % at nominal power
voltage_range 640 V - 920 V

Physical / mechanical

cooling smart forced air cooling
dimensions_mm 1136 mm * 870 mm * 361 mm
enclosure_material UNKNOWN
mounting_type ['UNKNOWN']
weight_kg <= 116

Installation

ac_connector OT / DT terminal
dc_connector MC4-Evo2 (max. 6 mm2, optional 10 mm2)
indoor_outdoor outdoor (IP66)
max_installation_altitude_m 4000 m
mounting_orientation UNKNOWN

Environment

cooling smart forced air cooling
corrosion_class C5
fan_replaceable UNKNOWN
ip_rating IP66
max_altitude_m 4000 m
night_power_consumption < 6 W
noise_db UNKNOWN
operating_temperature -30 C to 60 C
relative_humidity UNKNOWN

Interfaces & connectors

bluetooth yes (Bluetooth + APP)
can none documented
communication_label RS485 / PLC
display LED, Bluetooth + APP
ethernet not documented in the fetched datasheet
isolarcloud_dependency iSolarCloud used for plant monitoring; no local-operation dependency stated
local_communication RS485 / PLC
logger_support NOT_LISTED in Compatibility List 4.3
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
plc yes (power line communication)
register_map_availability UNKNOWN
rs485 yes
wifi not documented
winet_support NOT_LISTED - the Compatibility List 4.3 WiNet rows cover SGxxRS / SGxxRT / SGxxCX only

Protection

afci not stated in the fetched HX datasheet protection row - UNKNOWN
anti_islanding yes
dc_reverse_polarity yes (DC reverse connection protection)
dc_switch yes (DC and AC switches)
grid_protection grid monitoring; LVRT, HVRT, active and reactive power control, power ramp rate control, Q-U control, P-f control
insulation_monitoring ground fault monitoring yes; PV string current monitoring yes
pid anti-PID capability
q_at_night yes
rcmu leakage current protection yes
spd Type II DC and AC surge protection

Certifications

grid_codes ['IEC 62109', 'IEC 61727', 'IEC 62116', 'IEC 60068', 'IEC 61683', 'VDE-AR-N 4110:2018', 'VDE-AR-N 4120:2018', 'EN 50549-2', 'UNE 206007-1:2013', 'P.O.12.3', 'UTE C15-712-1:2013']
grid_support Q at night function, LVRT, HVRT, active and reactive power control, power ramp rate control, Q-U control, P-f control

Warranty & service

extension_options UNKNOWN
note no warranty statement appears in the fetched datasheet extraction
standard_warranty UNKNOWN

Documents

compatibility-list Sungrow Compatibility List Public 2026 (Version 4.3) rev 4.3
datasheet SG320HX Datasheet V17 EN rev Version 17
datasheet SG350HX Datasheet V23 EN rev Version 23
product-page SG320/350HX official product page rev UNKNOWN
product-page Sungrow string inverter product index (official website) rev UNKNOWN

Recorded conflicts

electrical.rated_ac_power_w / max_apparent_power_va / max_output_current_a / rated_output_current_a Review required
'352 kVA @ 30 C / 320 kVA @ 40 C / 295 kVA @ 50 C', max. AC output current 254 A, nominal output current 231 A — document[0]
the identical string '352 kVA @ 30 C / 320 kVA @ 40 C / 295 kVA @ 50 C' with max. AC output current 254 A — document[2]
'Rated Output Power 320/350 kW' for the SG320HX / SG350HX pair — document[1]

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

identity.product_statusactive - listed on the official 2026 sungrowpower.com string-inverter index as 'SG320/350HX (320/350kW)'; datasheet Version 23 is dated 2025-06-17
manufacturer_legal_entity_as_printedSungrow Power Supply Co., Ltd.

Build a system with this product