ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseInverters

Sungrow SG6.0RT-P2

Official manufacturer EU / GL verified Sept. 3, 2026

Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.

Identity

category inverters
ean UNKNOWN
generation RT-P2 (2nd generation of the RT platform)
grid_type TN / TT
hardware_revision UNKNOWN
legacy_name UNKNOWN
manufacturer Sungrow
manufacturer_legal_entity Sungrow Power Supply Co., Ltd.
market_version UNKNOWN
model SG6.0RT-P2
mpn UNKNOWN
order_code UNKNOWN
phase_configuration three-phase (3 / N / PE)
product_family SG5.0-12RT-P2 (RT-P2 three-phase residential/small-commercial string inverter)
product_status active
product_status_detail active - listed on the official 2026 sungrowpower.com string-inverter index as 'SG5/6/7/8/10/12RT-P2 (5~12kW)'
product_status_evidence official product index fetched 2026-09-03
region EU / GL
release_year UNKNOWN
sku UNKNOWN
subcategory grid-tied PV string inverter (three-phase, no battery interface)
topology transformerless (no galvanic isolation)
variant_note '-P2' is a distinct generation, not a trim level: vs the non-P2 SG6.0RT it changes the AC voltage range (175-276 V vs 180-276 V), the European efficiency and the DC input current rating. Never collapse the two.

Electrical

dc_ac_ratio 1.5
european_efficiency_pct 97.4
grid_frequency_range 45 Hz - 55 Hz / 55 Hz - 65 Hz
max_ac_power_w 6600
max_apparent_power_va 6600
max_dc_short_circuit_current_total_a UNKNOWN - see verification_notes
max_dc_voltage_v 1100
max_efficiency_pct 98.4
max_input_current_per_input_a 16 A per string (official product page headline: '16A Single String Input Current')
max_input_current_per_mppt_a UNKNOWN - see verification_notes
max_input_current_total_a UNKNOWN - see verification_notes (row-offset defect; two independent extractions of the same file disagreed)
max_output_current_a 10.0
max_pv_input_power_w UNKNOWN
max_short_circuit_current_per_mppt_a UNKNOWN - see verification_notes
min_operating_voltage_v 160
mppt_voltage_max_v 1000
mppt_voltage_min_v 160
mppt_voltage_range_for_nominal_power UNKNOWN
night_power_consumption UNKNOWN
nominal_dc_voltage_v 600
nominal_frequency 50 Hz / 60 Hz
nominal_voltage 3 / N / PE, 220/380 V; 230/400 V; 240/415 V (product page headline: 415 V)
num_mppt 2
num_pv_inputs 2
oversizing_guidance recommended max PV input power 9.0 kWp vs 6000 W rated AC (1.5x)
power_factor_range > 0.99 default; 0.8 leading - 0.8 lagging
rated_ac_power_w 6000
rated_output_current_a UNKNOWN
recommended_pv_power_w 9000
regional_derate footnote flags separate limits for Belgium, Germany and Jordan; the per-country figures were not resolvable from the fetched extraction
startup_voltage_v 160
string_rules 1 / 1 strings on MPPT1 / MPPT2 respectively (2 PV inputs on 2 MPPTs); each string limited to 16 A per the product page
strings_per_mppt 1 / 1 (MPPT1 / MPPT2)
thd < 3 %
voltage_range 175 V - 276 V (phase) / 304 V - 478 V (line)

Physical / mechanical

cooling natural cooling (fanless)
depth_mm 195
dimensions_mm 370 (W) * 480 (H) * 195 (D)
enclosure_material UNKNOWN
height_mm 480
mounting_type ['wall-mounting bracket']
weight_kg 18
width_mm 370

Installation

ac_connector plug and play
dc_connector MC4 (max. 6 mm2)
indoor_outdoor indoor and outdoor (IP65)
max_installation_altitude_m 4000
mounting_orientation UNKNOWN

Environment

cooling natural cooling
corrosion_class C5 (official product page: 'IP65/C5 Protection')
ip_rating IP65
max_altitude_m 4000
noise_db UNKNOWN
operating_temperature -25 C to 60 C
relative_humidity UNKNOWN

Interfaces & connectors

bluetooth UNKNOWN
can none documented
communication_label WLAN / Ethernet / RS485 / DI / DO
display UNKNOWN
ethernet yes
isolarcloud_dependency iSolarCloud for monitoring; no local-operation dependency stated
local_communication RS485 / DI / DO
logger_support NOT_LISTED for SGxxRT-P2 in Compatibility List 4.3
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
register_map_availability UNKNOWN
rs485 yes
wifi yes (WLAN)
winet_support yes - Compatibility List 4.3 lists WiNet-S/S2 for SGxxRT-P2 (max. 1 device)

Protection

afci yes - AFCI 2.0 per the official product page, with 0.2 s max. shutdown time
anti_islanding yes
dc_reverse_polarity yes
dc_switch UNKNOWN
grid_protection grid monitoring
insulation_monitoring yes
pid PID recovery function yes
rcmu leakage current protection yes
spd built-in DC Type II and AC Type II

Certifications

grid_codes IEC, EN, AS/NZS, VDE, UTE and other regional standards (extraction returned the list only at standards-body granularity)
safety UNKNOWN

Warranty & service

extension_options UNKNOWN
note no warranty statement appears in the fetched datasheet extraction
standard_warranty UNKNOWN

Documents

compatibility-list Sungrow Compatibility List Public 2026 (Version 4.3) rev 4.3
datasheet SG5.0/6.0/7.0/8.0/10/12RT-P2 Datasheet V2 EN rev Version 2
product-page SG5/6/7/8/10/12RT-P2 official product page rev UNKNOWN
product-page Sungrow string inverter product index (official website) rev UNKNOWN
user-manual {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} SG RT / RT-P2 User Manual (official CMS) — located, not retrieved rev UNKNOWN

Recorded conflicts

electrical.max_input_current_per_mppt_a / max_short_circuit_current_per_mppt_a Review required
attempt 1: 32 A (16/16) | 40 A (20/20) | 48 A (32/16) | 60 A (40/20) | 48 A (32/16) | 60 A (40/20) — document[0]
attempt 2 on the identical URL: '37.5 A, 48 A, 25 A, 32 A' — document[0]

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

identity.product_statusactive - listed on the official 2026 sungrowpower.com string-inverter index as 'SG5/6/7/8/10/12RT-P2 (5~12kW)'
manufacturer_legal_entity_as_printedSungrow Power Supply Co., Ltd.

Build a system with this product