ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseInverters

Sungrow SH10RT-20 (also marketed as SH10RT)

Official manufacturer global (EN datasheet); AU and EU variants published separately verified Sept. 3, 2026

Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.

Identity

brand Sungrow
category inverters
ean UNKNOWN
generation RT-20 disputed
grid_type 3 / N / PE
hardware_revision -20
legacy_name SH10RT (the -20 unit is frequently marketed simply as SH10RT)
manufacturer Sungrow
market_version IEC/EN + AS/NZS 4777.2:2020 (datasheet V22 compliance line) disputed
model SH10RT-20 (also marketed as SH10RT)
mpn UNKNOWN
order_code UNKNOWN
phase_configuration three-phase
product_family SH5.0RT / SH6.0RT / SH8.0RT / SH10RT / SH5.0RT-20 / SH6.0RT-20 / SH8.0RT-20 / SH10RT-20 disputed
product_revision -20 (second-generation RT hardware; datasheet and manual treat SH10RT and SH10RT-20 as distinct columns)
product_status active
product_status_evidence Model still listed on Sungrow's official product pages / current datasheets as of 2026-09-03; no explicit lifecycle statement was located.
region global (EN datasheet); AU and EU variants published separately
release_year UNKNOWN
sku UNKNOWN
subcategory residential hybrid / storage inverter
topology Transformerless (solar) / Transformerless (battery)
variant_note DISTINCT from the base SH10RT. Product page headline for the -20 generation is 'DC 13.5A current input, compatible with high-power PV module' (base RT is 12.5 A per string). The -20 also pairs with meter DTSU666-20 rather than DTSU666. No value has been carried across from the base model.

Electrical

ac_coupling_support UNKNOWN
backup_eps_output_support True
battery_support True
battery_type Lithium battery
battery_voltage_class HV
battery_voltage_max_v 600
battery_voltage_min_v 150
communication_can True
communication_ethernet True
communication_rs485 True
communication_wifi True
ct_support true - Current Transformers (3 or 6, region dependent) are shipped in the box per user manual Ver24 package-contents list
dc_ac_ratio 1.5
dc_current_injection < 0.5 % In
european_efficiency_pct 97.9
feed_in_phases_connection_phases 3 / 3
frequency_range 45 Hz - 55 Hz
generator_input_support UNKNOWN
grid_certifications ['IEC / EN 62109-1/-2', 'IEC / EN 61000-6-1/2/3/4', 'EN 62477-1', 'IEC 61727', 'IEC 62116', 'IEC 61683', 'VDE-AR-N-4105', 'AS/NZS 4777.2:2020', 'EN 50549-1', 'NRS 097-2-1', 'TOR Generator Type A', 'OVE-Richtlinie R25', 'NC RfG', 'PTPiREE', 'PSE 2018', 'EIFS 2018:2', 'PPDS4', 'NTS 631 V2.0', 'UNE 217002', 'RD 1699', 'CEI 0-21']
SH5.0/6.0/8.0/10RT-20 Datasheet — compliance line, datasheet V22
grid_export_control UNKNOWN
home_assistant_integration UNKNOWN
max_ac_power_from_grid_w 20600
max_ac_power_kw 12
max_ac_power_w 10000
max_apparent_power_va 10000
max_battery_charge_current_a 30
max_battery_charge_power_kw 10.6
max_battery_discharge_current_a 30
max_dc_voltage_v 1000
max_efficiency_pct 98.4
max_input_current_per_input_a 13.5
max_input_current_per_mppt_a 27A (standard) / 36A (enhanced-current version) per MPPT disputed
max_output_current_a 15.2
max_pv_input_power_w 15000
max_short_circuit_current_per_input_a 18
max_short_circuit_current_per_mppt_a 54 A (18 A / 36 A) - datasheet V22/V23 label 'Max. DC short-circuit current'; split is MPPT1 / MPPT2 disputed
SH5.0/6.0/8.0/10RT-20 Datasheet — 'Max. DC short-circuit current 54 A (18 A / 36 A)'; V23 (document 4) prints the identical figure
modbus_rtu UNKNOWN
modbus_tcp True
mppt_max_voltage_v 950
mppt_min_voltage_v 200
mppt_voltage_max_v 950
mppt_voltage_min_v 200
mppt_voltage_range 200 V - 950 V
nominal_dc_voltage_v 600
nominal_frequency 50 Hz
nominal_voltage 3 / N / PE, 220 V / 380 V; 230 V / 400 V
num_mppt 2
num_pv_inputs 3
officially_supported_battery_brands ['Sungrow SBR064 (FW >= SBRBCU-S_22011.01.18; inverter FW >= SAPPHIREH_B001.V000.P007-20240223)', 'Sungrow SBR096/128/160/192/224/256 (FW >= SBRBCU-S_22011.01.16; inverter FW >= SAPPHIREH_B000.V000.P005)', 'Sungrow SBH150/200/250/300/350 (FW >= SBHBCU-S_22011.04.02; inverter FW >= SAPPHIREH_B001.V000.P007-20240223)', "BYD and Pylontech (manual: 'Li-ion battery from SUNGROW, BYD and Pylontech are compatible'; models/FW not listed in fetched excerpt)"]
oversizing_guidance Recommended max. PV input power 15000 Wp
phase_type three-phase
power_factor_range > 0.99 at rated power / adjustable 0.8 leading to 0.8 lagging
pv_inputs_per_mppt 2
rated_ac_power_kw 10
rated_ac_power_w 10000
recommended_pv_power_w 15000
smart_meter_support Sungrow DTSU666-20 (SH-RT-20 hardware) / Sungrow DTSU666 (original SH-RT) per official manual
startup_voltage_v 200 or 250 (standard vs enhanced-current version) disputed
string_rules No. of strings per MPP input = 1 / 2
sunspec_support UNKNOWN
thd < 3 % (of rated power)
topology hybrid
voltage_range 270 V - 480 V

Physical / mechanical

bracket_dimensions_mm UNKNOWN
cable_entry_positions UNKNOWN
cable_gland_sizes UNKNOWN
cooling Natural convection
depth_mm 170
dimensions 460 mm * 540 mm * 170 mm (W * H * D)
display LED
enclosure_material UNKNOWN
height_mm 540
housing_color UNKNOWN
ip_rating IP65
mounting Wall-mounting bracket
mounting_bolt_size expansion plug set x 4 supplied (size not printed in the fetched quick guide / manual)
mounting_hole_diameter_mm UNKNOWN
mounting_hole_spacing_mm UNKNOWN
mounting_plate_dimensions_mm UNKNOWN
mounting_type ['wall']
noise_db 30 dB (A)
screw_sizes M4 (wall-mount fixing screws + washers, 2 supplied); M3 in quick guide
shipping_weight_kg UNKNOWN
terminal_locations UNKNOWN
torque_specs wall-mounting M4 screw 1.5 N.m (manual p.38); AC/Backup connector 1.2-1.5 N.m (manual p.53); PV connector swivel nut 2.5-3 N.m (manual p.59); quick guide adds M3 0.5 N.m, 7-7.5 N.m and battery connector 2 N.m
weight_kg 27
SH5.0/6.0/8.0/10RT-20 Datasheet — system data, 'Weight 27kg'
width_mm 460
SH5.0/6.0/8.0/10RT-20 Datasheet — system data, 'Dimensions (W * H * D) 460mm x 540mm x 170mm' (manual p.9 gives 460/540/170, 27 kg)

Installation

ac_connection_type Plug and play connector (Grid Max.10 mm2, Backup Max.6 mm2)
altitude_derating_note UNKNOWN
clearance_bottom_mm UNKNOWN
clearance_front_mm UNKNOWN
clearance_left_mm UNKNOWN
clearance_note Quick guide clearance diagram prints the values '>= 400 mm', '>= 450 mm', '>= 600 mm' and '>= 1000 mm'; the direction each applies to could not be resolved from the fetched text extraction, so no per-direction value is stored.
clearance_right_mm UNKNOWN
clearance_top_mm UNKNOWN
dc_connection_type MC4 (PV, Max.6 mm2) / Evo2 Compatible (Battery, Max.6 mm2)
direct_sunlight_restriction manual p.30: 'Do not store the inverter in places susceptible to direct sunlight'
indoor_outdoor indoor and outdoor (IP65)
max_installation_altitude_m 4000
minimum_wall_thickness_mm UNKNOWN
mounting_orientation vertical only
SH5.0RT/SH6.0RT/SH8.0RT/SH10RT & -20 User Manual — manual p.35: 'Install the inverter vertically. Never install the inverter horizontally, or at forward/backward tilted, or upside down.'
orientation_allowed ['vertical']
orientation_forbidden ['horizontal', 'forward tilt', 'backward tilt', 'upside down']
surface_requirements UNKNOWN
two_person_lift_required manual p.37: 'Move the inverter by one or two people or by using a proper transport tool'
ventilation_requirements reserve clearance for heat dissipation (manual)

Environment

cooling_method natural convection
fan_replaceable N/A (fanless)
ik_rating UNKNOWN
ip_rating IP65
max_altitude_m 4000
nema_rating UNKNOWN
noise_level_db 30 dB(A) (typical)
SH5.0/6.0/8.0/10RT-20 Datasheet — 'Noise (Typical) 30 dB(A)'
operating_temperature -25 C - 60 C
operating_temperature_c -25 to 60
SH5.0/6.0/8.0/10RT-20 Datasheet — 'Operating ambient temperature range -25 C ~ 60 C'
relative_humidity 0 % - 100 % (datasheet); manual storage spec '0 and 95 %, non-condensing' disputed
storage_temperature_c -30 to +70

Interfaces & connectors

ac_terminal_type plug-and-play connector (AC/Backup connector set, cable 6-10 mm2)
backup_eps_terminal dedicated Backup connector (AC/Backup connector set x 2 in the box)
battery_terminal_type MC4-Evo2 compatible connector
bluetooth UNKNOWN
can yes - BMS/CAN for battery communication disputed
di_do DI * 4 / DO * 1 / DRM
digital_inputs 4 x DI (DI/DRM, DRM0-DRM8 supported)
dry_contacts 1 x DO
ethernet yes (LAN connector supplied) disputed
isolarcloud_dependency UNKNOWN
local_communication RS485, WLAN, Ethernet, CAN, 4 x DI, 1 x DO
logger_support UNKNOWN
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
protocol_notes Datasheet V22 'Communication: RS485, WLAN, Ethernet, CAN, 4 x DI, 1 x DO'. Cable sizes (manual p.44): AC 6-10 mm2, DC 4-6 mm2, communication 2 x (0.5-1.0) mm2.
pv_connector_type MC4 (datasheet 'DC connection type: MC4 (PV) / Evo2 Compatible (Battery)')
SH5.0/6.0/8.0/10RT-20 Datasheet — 'DC connection type MC4 (PV) / Evo2 Compatible (Battery)'
register_map_availability Communication Protocol of Residential and Small Industrial Hybrid Inverter (located on product page, not fetched)
relay_outputs 1 x DO (multi-function dry contact relay, manual p.23)
rs485 yes - COM2 RS485 (A1,B1) default EV charger / parallel; COM2 Meter (A2,B2) for Smart Energy Meter disputed
usb UNKNOWN
wifi yes via WiNet-S module (supplied) disputed
winet_support WiNet-S / WiNet-S2

Controls & display

display_type LED
leds LED indicator
local_display True
mobile_app iSolarCloud
touchscreen False

Protection

afci Not mentioned in the fetched datasheet V23 or user manual Ver24
anti_islanding yes (manual p.21 'anti-islanding protection')
battery_reverse_polarity True
dc_overcurrent_protection_battery True
dc_reverse_polarity True
dc_switch DC switch (solar): Yes
grid_protection Grid monitoring: Yes
insulation_monitoring yes ('grounding insulation resistance surveillance', manual p.21)
integrated_dc_switch True
over_current yes ('DC overvoltage / over-current protection', manual p.21)
over_voltage yes ('DC overvoltage ... protection', manual p.21)
rcmu Leakage current protection: Yes
residual_current_monitoring yes ('residual current protection', manual p.21)
reverse_polarity yes (DC reverse connection protection, datasheet)
short_circuit yes (manual p.21 'short circuit protection')
spd Surge protection: Yes
surge_protection Type II (datasheet V22 protection section; DC/AC split not resolved in fetched excerpt)

Certifications

standards_and_grid_codes IEC / EN 62109-1/-2, IEC / EN 61000-6-1/2/3/4, EN 62477-1, IEC 61727, IEC 62116, IEC 61683, VDE-AR-N-4105, AS/NZS 4777.2:2020, EN 50549-1, NRS 097-2-1, TOR Generator Type A, OVE-Richtlinie R25, NC RfG, PTPiREE, PSE 2018, EIFS 2018:2, PPDS4, NTS 631 V2.0, UNE 217002, RD 1699, CEI 0-21

Warranty & service

warranty_note No warranty row was present in any fetched datasheet.
warranty_years UNKNOWN

Documents

datasheet SH5.0/6.0/8.0/10RT-20 Datasheet rev V22
datasheet SH5.0/6.0/8.0/10RT-20 Datasheet rev Version 23
datasheet SH5.0/6.0/8.0/10RT-20 Datasheet V23 (mirror) rev V23
product-page SH5.0/6.0/8.0/10RT-20 product page rev live page
quick-start SH5.0-10RT / SH5.0-10RT-20 Quick Installation Guide rev QIMUL-Ver21-202212
user-manual SH5.0RT/SH6.0RT/SH8.0RT/SH10RT & -20 User Manual rev SH5.0-10RT&SH5.0-10RT-20-UEN-Ver24

Documented compatibility

Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.

inverter_battery

Sungrow SBR128 COMPATIBLEofficially-verified
Sungrow SBR Datasheet + SBR/SBH Cross Reference Chart
BYD Battery-Box Premium HVS 12.8 COMPATIBLEmanufacturer-documented
BYD Battery-Box Premium HVS&HVM Compatible Inverter List V2.21 (2025-08-20)
BYD Battery-Box Premium HVM 11.0 COMPATIBLEmanufacturer-documented
BYD Battery-Box Premium HVS&HVM Compatible Inverter List V2.21 (2025-08-20)
Pylontech Force H3 (FH10050 module stack) COMPATIBLEmanufacturer-documented
Compatibility List of Pylontech High Voltage ESS and Inverters Ver.2.40 (2025-08-15)
Pylontech Force H2 COMPATIBLEmanufacturer-documented
Compatibility List of Pylontech High Voltage ESS and Inverters Ver.2.40 (2025-08-15)
Sungrow SBH200 COMPATIBLEofficially-verified
Sungrow High Voltage LFP Battery (SBH) User Manual p.45 and p.54

inverter_meter

CHINT DTSU666 (and DTSU666-CT variant) COMPATIBLEmanufacturer-documented
Sungrow distributor listing (Sungrow DTSU666-20 CT)
Sungrow DTSU666-20 COMPATIBLEofficially-verified
Sungrow SHRT User Manual Ver24 2025-03 (info-support.sungrowpower.com, fetched 2026-09-01)

inverter_evse

go-e GmbH go-eCharger Gemini (11kW and 22kW variants) COMPATIBLEinferred-from-electrical-parameters
go-e Gemini Datasheet (open local API/Modbus TCP/MQTT) + third-party EMS tools (evcc, openWB)

Recorded conflicts

electrical.max_ac_power_from_grid_w Review required
20600 W (per-model column) — SH5.0/6.0/8.0/10RT-20 Datasheet V23 EN (info-support)
16500 W (single value returned when the same row was read from the storyblok mirror of V23) — V23 mirror on a.storyblok.com
electrical.max_short_circuit_current_per_mppt_a Review required
54 A (18 A / 36 A) - datasheet V22/V23 label 'Max. DC short-circuit current'; split is MPPT1 / MPPT2 — stored value
54 A (18 A / 36 A) — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
electrical.max_input_current_per_mppt_a Review required
27A (standard) / 36A (enhanced-current version) per MPPT — stored value
40.5 A (13.5 A / 27 A) — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
parallel.max_parallel_units Review required
5 ('Parallel operation on grid port / Max. No of inverters' = 'Master-slave mode / 5') — SH5.0/6.0/8.0/10RT-20 Datasheet V23 EN
2 ('Maximum two hybrid inverters with the same type can be connected in parallel') — SH5.0-10RT&SH5.0-10RT-20 User Manual Ver24-202503
interfaces.can Review required
yes - BMS/CAN for battery communication — stored value
True — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
interfaces.wifi Review required
yes via WiNet-S module (supplied) — stored value
Yes (WLAN, via WiNet-S / WiNet-S2) — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
interfaces.ethernet Review required
yes (LAN connector supplied) — stored value
True — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
interfaces.rs485 Review required
yes - COM2 RS485 (A1,B1) default EV charger / parallel; COM2 Meter (A2,B2) for Smart Energy Meter — stored value
True — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
environment.relative_humidity Review required
0 % - 100 % (datasheet); manual storage spec '0 and 95 %, non-condensing' — stored value
0 % - 100 % — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
electrical.startup_voltage_v Review required
200 or 250 (standard vs enhanced-current version) — stored value
200 V / 250 V — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
identity.generation Review required
RT-20 — stored value
SH-RT -20 (higher DC current) — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
identity.market_version Review required
IEC/EN + AS/NZS 4777.2:2020 (datasheet V22 compliance line) — stored value
-20 hardware generation — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
identity.product_family Review required
SH5.0RT / SH6.0RT / SH8.0RT / SH10RT / SH5.0RT-20 / SH6.0RT-20 / SH8.0RT-20 / SH10RT-20 — stored value
SH-RT-20 (3-phase residential hybrid) — incoming package
Detected during import sungrow-full-portfolio-2026-09-03
pv_inputs_per_mppt Review required
2 — existing ANMA record
1 / 2 — Sungrow datasheet V22, 'No. of PV strings per MPP input', SH10RT-20 column
SH10RT-20 has an asymmetric tracker layout: MPPT1 takes one string, MPPT2 takes two.
max_input_current_per_mppt_a Review required
27 A (standard) / 36 A (enhanced-current version) per MPPT — existing ANMA record, sourced from irishellas.com distributor PDF
Max. PV input current 40.5 A (13.5 A / 27 A); Max. DC short-circuit current 54 A (18 A / 36 A) — Sungrow datasheet V22 (2023-03-01) and V23 (2024-01-11), SH10RT-20 column
the existing record appears to have merged the MPPT2 input-current figure (27 A) with the MPPT2 short-circuit figure (36 A) and read them as two hardware versions. Sungrow prints 40.5 A total split 13.5 A (MPPT1, 1 string) / 27 A (MPPT2, 2 strings), and 54 A Isc split 18 A / 36 A.
pv_inputs_per_mppt Review required
2 — existing ANMA record
1 / 2 — Sungrow datasheet V22, 'No. of PV strings per MPP input', SH10RT-20 column
SH10RT-20 has an asymmetric tracker layout: MPPT1 takes one string, MPPT2 takes two.
max_input_current_per_mppt_a Review required
27 A (standard) / 36 A (enhanced-current version) per MPPT — existing ANMA record, sourced from irishellas.com distributor PDF
Max. PV input current 40.5 A (13.5 A / 27 A); Max. DC short-circuit current 54 A (18 A / 36 A) — Sungrow datasheet V22 (2023-03-01) and V23 (2024-01-11), SH10RT-20 column
the existing record appears to have merged the MPPT2 input-current figure (27 A) with the MPPT2 short-circuit figure (36 A) and read them as two hardware versions. Sungrow prints 40.5 A total split 13.5 A (MPPT1, 1 string) / 27 A (MPPT2, 2 strings), and 54 A Isc split 18 A / 36 A.

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

DC current injection< 0.5 % In
Installation clearance diagram>= 400 mm, >= 450 mm, >= 600 mm, >= 1000 mm
Master-slave / parallelmaster-slave capable, 5 inverters max
Max. AC power from grid20600 W
Max. PV input current40.5 A (13.5 A / 27 A)
Max. efficiency / European efficiency98.4 % / 97.9 %
No. of PV strings per MPP input1 / 2
Overload capacity (5 min)12000 W / 12000 VA, 5 min
Package contentsInverter, wall-mounting bracket, expansion plug set x4, M4 screws+washers x2, AC/Backup connector set x2, PV connector x2 or 3, LAN connector set, COM connector set, WiNet-S module, Smart Energy Meter, Current Transformer x3 or x6, 120 Ohm resistor
Product page headlineDC 13.5A current input, compatible with high-power PV module
Rated backup output power / peak10000 W / 10000 VA rated; 12000 W for 5 min; 20600 W peak
Rated output current for backup load / minimum battery energy3400 VA (>= 12.8 kWh)
documented_relationship:compatible_battery{"to_manufacturer": "Sungrow", "to_model": "SBR096 / SBR128 / SBR160 / SBR192 / SBR224 / SBR256", "relationship_type": "compatible_battery", "match_level": "series", "communication_protocol": "CAN (BMS)", "required_firmware": "SBRBCU-S_22011.01.16 or later per manual battery table", "required_settings": "UNKNOWN", "required_accessories": "UNKNOWN", "region": "Global", "source": "SH5.0-10RT&SH5.0-10RT-20 User Manual Ver24", "source_url": "https://info-support.sungrowpower.com/application/pdf/2025/07/17/SHRT%20User%20Manual.pdf", "source_page": "Compatible battery table", "confidence": "officially-verified", "status": "COMPATIBLE", "notes": "Listed as a series row in the manual; kept at series match_level."}
identity.model_as_researchedSH10RT-20
identity.region_as_researchedIEC / EU (datasheet V23 EN)
manufacturer_legal_entity_as_printedSungrow Power Supply Co., Ltd.

Build a system with this product