ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseInverters

Sungrow SH25T

Official manufacturer AU and IEC/EU editions fetched verified Sept. 3, 2026

Unresolved safety-relevant conflict
Two sources give different figures for a value on this product and nobody has resolved it. The specifications below are shown as recorded, but this product must not be treated as verified for engineering purposes until the conflict is closed.

Identity

category inverters
ean UNKNOWN
generation SH-T (successor generation to SH-RT)
grid_type 3 / N / PE
hardware_revision UNKNOWN
legacy_name UNKNOWN
manufacturer Sungrow
market_version AU + IEC editions
model SH25T
mpn UNKNOWN
order_code UNKNOWN
phase_configuration three-phase
product_family SH-T (3-phase residential hybrid, new generation)
product_status UNKNOWN
product_status_evidence Model still listed on Sungrow's official product pages / current datasheets as of 2026-09-03; no explicit lifecycle statement was located.
region AU and IEC/EU editions fetched
release_year UNKNOWN
sku UNKNOWN
subcategory residential hybrid / storage inverter
topology Transformerless (solar) / Transformerless (battery)
variant_note Three-MPPT, five-string sibling of SH5T-SH12T in the same SH-T generation. Larger chassis than SH5T-12T (620x480x245 mm vs 620x480x195 mm) and 245 mm deep.

Electrical

dc_ac_ratio 2.0
european_efficiency_pct 97.8
feed_in_phases_connection_phases 3 / 3-N-PE
frequency_range 45 Hz - 55 Hz / 55 Hz - 65 Hz
max_ac_power_from_grid_w 25000
max_ac_power_w 25000
max_apparent_power_va 25000
max_current_for_input_connector_a 30
max_dc_voltage_v 1000
max_efficiency_pct 98.2
max_input_current_per_input_a 16
max_input_current_per_mppt_a 80 A total (32 A / 32 A / 16 A) - see data_conflicts
max_output_current_a 37.9
max_pv_input_power_w UNKNOWN
max_short_circuit_current_per_input_a 20
max_short_circuit_current_per_mppt_a 100 A total (40 A / 40 A / 20 A) - see data_conflicts
mppt_voltage_max_v 950
mppt_voltage_min_v 150
mppt_voltage_range 150 V - 950 V
nominal_dc_voltage_v 600
nominal_frequency 50 Hz / 60 Hz
nominal_voltage 3 / N / PE, 220 V / 380 V; 230 V / 400 V; 240 V / 415 V
num_mppt 3
num_pv_inputs 5
oversizing_guidance Product page states DC/AC ratio up to 200 percent; datasheet recommended max PV input power 50000 Wp
power_factor_range > 0.99 at rated power / adjustable 0.8 leading to 0.8 lagging
rated_ac_power_w 25000
recommended_pv_power_w 50000
startup_voltage_v 150 V / 180 V (min. PV input voltage / startup)
string_rules No. of PV strings per MPPT = 2 / 2 / 1 (five strings across three MPPTs)
thd < 3 % (of rated power)
voltage_range 270 V - 480 V

Physical / mechanical

cooling Fan cooling
dimensions 620 mm * 480 mm * 245 mm (W * H * D)
display LED
ip_rating IP65 (product page states IP65/C5)
mounting Wall-mounting bracket
noise_db 50 dB (A)
weight_kg 40

Installation

ac_connection_type Plug and play connector (Max.16 mm2)
dc_connection_type MC4 compatible connector (PV, Max.6 mm2) / Plug and play connector (battery, Max.10 mm2)

Environment

max_altitude_m 2000
operating_temperature -25 C - 60 C
relative_humidity 0 % - 100 % (non-condensing)

Interfaces & connectors

can True
di_do DI * 4 / DO * 2 / DRM0
ethernet True
isolarcloud_dependency UNKNOWN
local_communication RS485, WLAN, Ethernet, CAN; DI * 4 / DO * 2 / DRM0
logger_support UNKNOWN
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
register_map_availability UNKNOWN
rs485 True
wifi Yes (WLAN, via WiNet-S2)
winet_support WiNet-S2 (manual states the module is included and supports Ethernet and WLAN)

Protection

afci Yes - 'AFCI2.0', product page states 200 ms arc-fault shutdown time
anti_islanding Frequency shift (active anti-islanding method, datasheet General data)
battery_reverse_polarity True
dc_reverse_polarity True
dc_switch DC switch (solar): Yes
grid_protection Grid monitoring: Yes
insulation_monitoring UNKNOWN
overvoltage_category III [AC]; II [PV]; [BATTERY]
pid_zero True
protective_class Protective class I
rcmu Leakage current protection: Yes
spd DC Type II / AC Type II

Certifications

country_of_manufacture China
standards_and_grid_codes IEC / EN 62109, IEC 61000-6, EN 62477-1, IEC 61727, IEC 62116, IEC 62920, EN 55011, CISPR 11, VDE-AR-N-4105, EN 50549-1, NRS 097, AS/NZS 4777.2:2020, TOR Type A, R25, CEI 0-21

Warranty & service

warranty_note No warranty row was present in any fetched datasheet.
warranty_years UNKNOWN

Documents

datasheet SH15/20/25T Datasheet rev Version 3
datasheet SH15/20/25T Datasheet (Version 2) - mirror on dsenergy.com.au rev Version 2
datasheet SH15/20/25T Datasheet (Version 3, IEC) - mirror on pvo-int.com rev Version 3
datasheet SH15/20/25T product page (Sungrow AU) rev UNKNOWN
datasheet SHT 15/20/25 product page rev UNKNOWN
installation_manual {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} SH5T-25T Wiring Diagram — located, not retrieved rev UNKNOWN
quick_guide {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} SH5T/6T/8T/10T/12T/15T/20T/25T Quick Installation Guide — located, not retrieved rev UNKNOWN
user_manual User Manual 3-Phase Hybrid Inverter SH5T/6T/8T/10T/12T/15T/20T/25T rev SH5_6_8_10_12_15_20_25T-UEN-Ver17-202504

Recorded conflicts

battery.max_charge_power_kw Review required
15000 W / 15000 VA (SH15T), 20000 W / 20000 VA (SH20T), 25000 W / 25000 VA (SH25T) — SH15/20/25T Datasheet Version 2 (dsenergy.com.au mirror) and Version 3 IEC (pvo-int mirror)
43000 VA (single value for all three) — SH15/20/25T Datasheet V3 EN(AU) (info-support.sungrowpower.com)
backup.on_grid_max_backup_load_power_w Review required
43000 W (same value returned for SH15T, SH20T and SH25T) — SH15/20/25T Datasheet V3 EN(AU) and V2 mirror
UNKNOWN - an identical 43000 W for three different power classes is implausible and matches no other row — self-check
electrical.max_short_circuit_current_per_mppt_a Review required
Max. PV input current = 80 A (32/32/16); Max. DC short-circuit current = 100 A (40/40/20) — Reading aligned with the identical 10-row DC block of the SH5/6/8/10/12T datasheet and the official '16 A per string' spec
Max. PV input current = 30 A; Max. DC short-circuit current = 80 A (32/32/16) for SH15T and 100 A (40/40/20) for SH20T/SH25T — SH15/20/25T Datasheet Version 2 (dsenergy.com.au mirror)

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

AFCI2.0 shutdown time200 ms
Active anti-islanding methodFrequency shift
Built-in bypassBuilt-in 63A bypass for full house backup
DC/AC Ratio200 %
Max. current for input connector30 A
Overvoltage categoryIII[AC]; II[PV]; [BATTERY]
Protective classProtective class I
documented_relationship:compatible_battery{"to_manufacturer": "Sungrow", "to_model": "SBR096 / SBR128 / SBR160 / SBR192 / SBR224 / SBR256", "relationship_type": "compatible_battery", "match_level": "series", "communication_protocol": "CAN (BMS)", "required_firmware": "SBRBCU-S_22011.01.19 or later", "required_settings": "UNKNOWN", "required_accessories": "UNKNOWN", "region": "Global", "source": "SH5T-25T User Manual Ver17", "source_url": "https://info-support.sungrowpower.com/application/pdf/2025/07/17/SH5-25T-EN-Ver17-202504.pdf", "source_page": "Compatible battery table", "confidence": "officially-verified", "status": "COMPATIBLE", "notes": ""}
manufacturer_legal_entity_as_printedSungrow Power Supply Co., Ltd.

Build a system with this product