Identity
| category | inverters |
| ean | UNKNOWN |
| generation | SH-RT -20 (higher DC current) |
| grid_type | 3 / N / PE |
| hardware_revision | -20 |
| legacy_name | UNKNOWN |
| manufacturer | Sungrow |
| market_version | -20 hardware generation |
| model | SH8.0RT-20 |
| mpn | UNKNOWN |
| order_code | UNKNOWN |
| phase_configuration | three-phase |
| product_family | SH-RT-20 (3-phase residential hybrid) |
| product_status | UNKNOWN |
| product_status_evidence | Model still listed on Sungrow's official product pages / current datasheets as of 2026-09-03; no explicit lifecycle statement was located. |
| region | IEC / EU (datasheet V23 EN) |
| release_year | UNKNOWN |
| sku | UNKNOWN |
| subcategory | residential hybrid / storage inverter |
| topology | Transformerless (solar) / Transformerless (battery) |
| variant_note | DISTINCT from the base SH8.0RT. Product page headline for the -20 generation is 'DC 13.5A current input, compatible with high-power PV module' (base RT is 12.5 A per string). The -20 also pairs with meter DTSU666-20 rather than DTSU666. No value has been carried across from the base model. |
Electrical
| dc_ac_ratio | 1.5 |
| dc_current_injection | < 0.5 % In |
| european_efficiency_pct | 97.9 |
| feed_in_phases_connection_phases | 3 / 3 |
| frequency_range | 45 Hz - 55 Hz |
| max_ac_power_from_grid_w | 18600 |
| max_ac_power_w | 8000 |
| max_apparent_power_va | 8000 |
| max_dc_voltage_v | 1000 |
| max_efficiency_pct | 98.4 |
| max_input_current_per_input_a | 13.5 |
| max_input_current_per_mppt_a | 27 A (13.5 A / 13.5 A) |
| max_output_current_a | 12.1 |
| max_pv_input_power_w | UNKNOWN |
| max_short_circuit_current_per_input_a | 18 |
| max_short_circuit_current_per_mppt_a | 36 A (18 A / 18 A) |
| mppt_voltage_max_v | 950 |
| mppt_voltage_min_v | 200 |
| mppt_voltage_range | 200 V - 950 V |
| nominal_dc_voltage_v | 600 |
| nominal_frequency | 50 Hz |
| nominal_voltage | 3 / N / PE, 220 V / 380 V; 230 V / 400 V |
| num_mppt | 2 |
| num_pv_inputs | 2 |
| oversizing_guidance | Recommended max. PV input power 12000 Wp |
| power_factor_range | > 0.99 at rated power / adjustable 0.8 leading to 0.8 lagging |
| rated_ac_power_w | 8000 |
| recommended_pv_power_w | 12000 |
| startup_voltage_v | 200 V / 250 V |
| string_rules | No. of strings per MPP input = 1 / 1 |
| thd | < 3 % (of rated power) |
| voltage_range | 270 V - 480 V |
Physical / mechanical
| cooling | Natural convection |
| dimensions | 460 mm * 540 mm * 170 mm (W * H * D) |
| display | LED |
| ip_rating | IP65 |
| mounting | Wall-mounting bracket |
| noise_db | 30 dB (A) |
| weight_kg | 27 |
Installation
| ac_connection_type | Plug and play connector (Grid Max.10 mm2, Backup Max.6 mm2) |
| dc_connection_type | MC4 (PV, Max.6 mm2) / Evo2 Compatible (Battery, Max.6 mm2) |
Environment
| max_altitude_m | 4000 |
| operating_temperature | -25 C - 60 C |
| relative_humidity | 0 % - 100 % |
Interfaces & connectors
| can | True |
| di_do | DI * 4 / DO * 1 / DRM |
| ethernet | True |
| isolarcloud_dependency | UNKNOWN |
| local_communication | RS485, WLAN, Ethernet, CAN, 4 x DI, 1 x DO |
| logger_support | UNKNOWN |
| modbus_rtu | UNKNOWN |
| modbus_tcp | UNKNOWN |
| register_map_availability | Communication Protocol of Residential and Small Industrial Hybrid Inverter (located on product page, not fetched) |
| rs485 | True |
| wifi | Yes (WLAN, via WiNet-S / WiNet-S2) |
| winet_support | WiNet-S / WiNet-S2 |
Protection
| afci | Not mentioned in the fetched datasheet V23 or user manual Ver24 |
| anti_islanding | UNKNOWN |
| battery_reverse_polarity | True |
| dc_overcurrent_protection_battery | True |
| dc_reverse_polarity | True |
| dc_switch | DC switch (solar): Yes |
| grid_protection | Grid monitoring: Yes |
| insulation_monitoring | UNKNOWN |
| rcmu | Leakage current protection: Yes |
| spd | Surge protection: Yes |
Certifications
| standards_and_grid_codes | IEC / EN 62109-1/-2, IEC / EN 61000-6-1/2/3/4, EN 62477-1, IEC 61727, IEC 62116, IEC 61683, VDE-AR-N-4105, AS/NZS 4777.2:2020, EN 50549-1, NRS 097-2-1, TOR Generator Type A, OVE-Richtlinie R25, NC RfG, PTPiREE, PSE 2018, EIFS 2018:2, PPDS4, NTS 631 V2.0, UNE 217002, RD 1699, CEI 0-21 |
Warranty & service
| warranty_note | No warranty row was present in any fetched datasheet. |
| warranty_years | UNKNOWN |
Documents
user_manual
User Manual 3-Phase Hybrid Inverter SH5.0RT/SH6.0RT/SH8.0RT/SH10RT/SH5.0RT-20/SH6.0RT-20/SH8.0RT-20/SH10RT-20
rev SH5.0-10RT&SH5.0-10RT-20-UEN-Ver24-202503
Recorded conflicts
electrical.max_ac_power_from_grid_w Review required
18600 W (per-model column) — SH5.0/6.0/8.0/10RT-20 Datasheet V23 EN (info-support)
16500 W (single value returned when the same row was read from the storyblok mirror of V23) — V23 mirror on a.storyblok.com
parallel.max_parallel_units Review required
5 ('Parallel operation on grid port / Max. No of inverters' = 'Master-slave mode / 5') — SH5.0/6.0/8.0/10RT-20 Datasheet V23 EN
2 ('Maximum two hybrid inverters with the same type can be connected in parallel') — SH5.0-10RT&SH5.0-10RT-20 User Manual Ver24-202503
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| DC current injection | < 0.5 % In |
| Max. AC power from grid | 18600 W |
| Overload capacity (5 min) | 12000 W / 12000 VA, 5 min |
| Product page headline | DC 13.5A current input, compatible with high-power PV module |
| Rated output current for backup load / minimum battery energy | 2700 VA (>= 12.8 kWh) |
| documented_relationship:compatible_battery | {"to_manufacturer": "Sungrow", "to_model": "SBR096 / SBR128 / SBR160 / SBR192 / SBR224 / SBR256", "relationship_type": "compatible_battery", "match_level": "series", "communication_protocol": "CAN (BMS)", "required_firmware": "SBRBCU-S_22011.01.16 or later per manual battery table", "required_settings": "UNKNOWN", "required_accessories": "UNKNOWN", "region": "Global", "source": "SH5.0-10RT&SH5.0-10RT-20 User Manual Ver24", "source_url": "https://info-support.sungrowpower.com/application/pdf/2025/07/17/SHRT%20User%20Manual.pdf", "source_page": "Compatible battery table", "confidence": "officially-verified", "status": "COMPATIBLE", "notes": "Listed as a series row in the manual; kept at series match_level."} |
| manufacturer_legal_entity_as_printed | Sungrow Power Supply Co., Ltd. |