ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseInverters

Victron Energy MultiPlus-II 230V 12/4k/160-32

Official manufacturer 230V / EU verified Sept. 2, 2026

Identity

category inverters
manufacturer Victron Energy B.V.
market_version 230 VAC 50 Hz
model MultiPlus-II 230V 12/4k/160-32
product_family MultiPlus-II 230V (4k/4k5/6k5/10k family)
product_status active
region 230V / EU
release_year UNKNOWN
sku UNKNOWN

Electrical

ac_output_frequency 50 Hz ± 0.1 %
ac_output_voltage 230 VAC ± 2 %
battery_temperature_sensor Yes
charge_voltage_absorption_v 14.4
charge_voltage_float_v 13.8
charge_voltage_storage_v UNKNOWN
cont_output_power_at_25c_va UNKNOWN
cont_output_power_at_25c_w 3400
cont_output_power_at_40c_w 3100
cont_output_power_at_65c_w 2600
dc_input_voltage_range 9,5-17 V
maximum_charge_current_at_25c_a 160
maximum_efficiency_pct 93
peak_power UNKNOWN
system_dc_voltage_v 12
transfer_switch_a 32
zero_load_power_w UNKNOWN

Physical / mechanical

depth_mm 164
enclosure_material Steel, blue RAL 5012
height_mm 576
mounting_type ['wall-mount']
terminal_locations UNKNOWN
torque_specs UNKNOWN
weight_kg 22
width_mm 276

Installation

minimum_clearance UNKNOWN

Environment

altitude UNKNOWN
cooling UNKNOWN
humidity max 95 % (non-condensing)
ip_rating IP21
operating_temperature_range -40 to +65 °C

Interfaces & connectors

bluetooth UNKNOWN
ethernet UNKNOWN
modbus UNKNOWN
relay Programmable relay: Yes
ve_bus For parallel and three phase operation, remote monitoring and system integration
ve_can UNKNOWN
ve_direct UNKNOWN

Protection

list ['output short circuit', 'overload', 'battery voltage too high', 'battery voltage too low', 'temperature too high', '230 VAC on inverter output', 'input voltage ripple too high']

Certifications

standards ['EN-IEC 60335-1', 'EN-IEC 60335-2-29', 'EN-IEC 62109-1', 'EN-IEC 62109-2']

Warranty & service

summary UNKNOWN

Documents

datasheet Datasheet MultiPlus-II inverter/charger 4k 4k5 6k5 10k rev UNKNOWN

Build a system with this product