ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseInverters

Victron Energy MultiPlus-II 48/3000/35-32

Official manufacturer 230V / EU verified Sept. 2, 2026

Identity

category inverters
manufacturer Victron Energy B.V.
market_version 230 VAC 50 Hz
model MultiPlus-II 48/3000/35-32
product_family MultiPlus-II 230V
product_status active
region 230V / EU
release_year UNKNOWN
sku UNKNOWN

Electrical

ac_output_frequency 50 Hz ± 0,1 %
ac_output_voltage 230 VAC ± 2 %
charge_voltage_absorption_v 57.6
charge_voltage_float_v 55.2
charge_voltage_storage_v 52.8
cont_output_power_at_25c_va 3000
cont_output_power_at_25c_w 2400
cont_output_power_at_40c_w 2200
cont_output_power_at_65c_w 1700
dc_input_voltage_range 38 - 66 V
maximum_ac_input_current_a 32
maximum_charge_current_a 35
maximum_efficiency_pct 95
peak_power_duration UNKNOWN
peak_power_w 5500
power_assist Yes
power_control Yes
system_dc_voltage_v 48
transfer_switch_a 32
zero_load_power_in_aes_mode_w UNKNOWN
zero_load_power_w 11

Physical / mechanical

depth_mm 141
enclosure_material Steel, blue RAL 5012
height_mm 499
mounting_type ['wall-mount']
terminal_locations Battery-connection: M8 bolts. 230 V AC-connection: Screw terminals 13 mm2 (6 AWG)
torque_specs Battery terminal M8 nut: 12 Nm; AC terminal M8 bolts: 12 Nm
weight_kg 19
width_mm 268

Installation

minimum_clearance at least 10cm for ventilation purposes under, above and beside the units
recommended_dc_cable_cross_section 0-5 m: 35 mm2; 5-10 m: 70 mm2
remote_on_off Yes

Environment

altitude UNKNOWN
cooling UNKNOWN
humidity max 95 % non-condensing
ip_rating IP22
operating_temperature_range -40 to +65 °C

Interfaces & connectors

bluetooth UNKNOWN
ethernet UNKNOWN
general_purpose_com_port Yes, 2x
modbus UNKNOWN
relay Programmable relay: Yes — AC rating: 230V / 4 A, DC rating: 4 A up to 35VDC and 1 A up to 60VDC
ve_bus For parallel and three phase operation, remote monitoring and system integration
ve_can UNKNOWN
ve_direct UNKNOWN

Protection

list ['Output short circuit', 'Overload', 'Battery voltage too high', 'Battery voltage too low', 'Temperature too high', '230 VAC on inverter output', 'Input voltage ripple too high']

Certifications

standards ['EN-IEC 60335-1', 'EN-IEC 60335-2-29', 'EN-IEC 62109-1', 'EN-IEC 62109-2', 'EN 55014-1', 'EN 55014-2', 'EN-IEC 61000-3-2', 'EN-IEC 61000-3-3', 'IEC 61000-6-1', 'IEC 61000-6-2', 'IEC 61000-6-3']

Warranty & service

summary UNKNOWN

Documents

datasheet Datasheet MultiPlus-II inverter/charger (230V, 3k/5k/8k/10k/15k) rev UNKNOWN
installation-manual MultiPlus-II / Quattro-II 230V manual rev doc id 32424
product-page MultiPlus-II official product page rev UNKNOWN

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Anti-islandingPlease consult the certificates on our website.
General purpose com. portYes, 2x
Material & ColourSteel, blue RAL 5012
PowerControl & PowerAssistYes
Remote on-offYes

Build a system with this product