Identity

brand Victron
category inverters
manufacturer Victron Energy
model MultiPlus-II 48/5000/70-50
product_family MultiPlus-II
region GLOBAL

Electrical

ac_coupling_support True
backup_eps_output_support True
battery_support True
battery_type Lead-acid / Lithium-ion (via VE.Bus BMS or CAN-bus BMS integration)
battery_voltage_class LV
battery_voltage_max_v 66
battery_voltage_min_v 38
communication_can UNKNOWN (VE.Bus is native; CAN typically added via a Cerbo/GX device)
communication_ethernet UNKNOWN (via optional GX device)
communication_rs485 UNKNOWN
communication_wifi UNKNOWN (Bluetooth via optional VE.Bus Smart Dongle; WiFi typically via GX device)
ct_support UNKNOWN
generator_input_support True
grid_certifications ['EN-IEC 60335-1', 'EN-IEC 60335-2-29', 'EN-IEC 62109-1/2', 'EN 55014-1/2', 'EN-IEC 61000-3-2/3-3', 'IEC 61000-6-1/2/3']
grid_export_control UNKNOWN
home_assistant_integration UNKNOWN
max_ac_power_kw 9
max_battery_charge_current_a 70
max_battery_charge_power_kw UNKNOWN
max_battery_discharge_current_a UNKNOWN
max_dc_voltage_v N/A
max_input_current_per_mppt_a N/A
max_pv_input_power_w N/A
max_short_circuit_current_per_mppt_a N/A
modbus_rtu UNKNOWN
modbus_tcp UNKNOWN
mppt_max_voltage_v N/A
mppt_min_voltage_v N/A
num_mppt 0
officially_supported_battery_brands UNKNOWN (see Victron's separate Battery Compatibility wiki, in relationships/sources)
phase_type single-phase (split/stackable to 3-phase)
pv_inputs_per_mppt N/A (no integrated PV input on this model)
rated_ac_power_kw 4
smart_meter_support UNKNOWN
startup_voltage_v N/A
sunspec_support UNKNOWN
topology hybrid (inverter/charger only - no built-in PV MPPT; PV connects via external Victron MPPT solar charger DC-coupled, or an AC-coupled PV inverter)

Physical / mechanical

depth_mm 149
enclosure_material Steel
height_mm 565
housing_color blue RAL 5012
mounting_type ['wall']
terminal_locations Battery M8 bolts; AC-in / AC-out-1 / AC-out-2 terminals wired N, PE, L
torque_specs M4 1 Nm, M5 3 Nm, M6 5.5 Nm, M8 12 Nm; battery 'Recommended torque: 12 Nm (M8 nut)'; AC-out-2 max 2 Nm
weight_kg 30
width_mm 320

Installation

clearance_bottom_mm 100
clearance_left_mm 100
clearance_right_mm 100
clearance_top_mm 100
indoor_outdoor indoor only (IP22)
max_installation_altitude_m 2000
mounting_orientation Vertical wall mounting preferred; hook and two holes at the rear of the casing
surface_requirements Solid surface such as concrete or masonry; dry, well-ventilated, close to the batteries; not directly above them
ventilation_requirements 'Allow at least 10cm for ventilation purposes under, above and beside the units'

Environment

cooling_method forced air (fan assisted)
ip_rating IP22
max_altitude_m 2000
operating_temperature_c -40 to +65 (fan assisted cooling); 4000 W at 25 C, 3700 W at 40 C, 3000 W at 65 C
pollution_degree 2
relative_humidity max 95 % (non-condensing)

Interfaces & connectors

battery_terminal_type M8 bolts
modbus_tcp Only through a GX device (Cerbo GX / Venus GX etc.); disabled by default
protocol_notes Native bus is VE.Bus only. Ethernet, Wi-Fi, CAN/BMS-Can, Modbus-TCP, MQTT and VRM all require a GX device.
relay_outputs 1 programmable relay - AC 230 V / 4 A; DC 4 A up to 35 VDC, 1 A up to 60 VDC
smart_load_output AC-out-2 auxiliary output, 50 A

Protection

ground_fault_protection Ground relay (relay H) bonds neutral to chassis when no external AC source is present
integrated_dc_switch False
overvoltage_category OVC3
protection_class Safety class I

Warranty & service

conditions 'industry-leading 5-year standard warranty and global repair service' (Victron product page)
standard_years 5

Documents

compatibility-list Victron Energy battery compatibility - Pylontech
datasheet MultiPlus-II inverter/charger Datasheet (EN)
installation-manual MultiPlus-II / Quattro-II 230V Manual, Rev 14 - 07/2026 rev Rev 14
installation-manual Parallel, split- and three-phase VE.Bus systems
modbus-manual GX device Modbus-TCP manual / FAQ

Documented compatibility

Documented pairings only. A product absent here has no fetched document naming the pairing — that is not a statement that it fails.

inverter_battery

Pylontech Force H2 COMPATIBLEofficially-verified
Victron Energy official battery compatibility page for Pylontech, https://www.victronenergy.com/live/battery_compatibility:pylontech_phantom (fetched 2026-09-01)
Deye AI-W5.1-B COMPATIBLEmanufacturer-documented
Deye Approved Battery List DY-LV48-0109
Pylontech US3000C COMPATIBLEofficially-verified
Pylontech Compatibility List Ver.2.35
BSLBATT B-LFP48-100E (3U Server Rack Battery) COMPATIBLEmanufacturer-documented
BSLBATT product page
BYD Battery-Box Premium HVM 11.0 COMPATIBLEinferred-from-electrical-parameters
BYD Battery-Box Premium HVM Datasheet V1.4 (operating voltage 160-236 V) + Victron MultiPlus-II 48 V nominal rating; Victron does not appear anywhere in BYD's HVS&HVM Compatible Inverter List V2.21
Pylontech Force H3 (FH10050 module stack) COMPATIBLEinferred-from-electrical-parameters
Pylontech Force H3 datasheet (system voltage 204.8-716.8 V) + Victron MultiPlus-II 48 V nominal rating; Victron does not appear in Pylontech's HV ESS compatibility list Ver.2.40
Pytes V5 / V5-alpha (printed as V5° / V5°α) COMPATIBLEofficially-verified
Pytes Inverter Compatibility List V.20230819, https://www.pytesess.com/ueditor/php/upload/file/20240705/1720170604646137.pdf (fetched 2026-09-01)
Pytes E-Box 48100R COMPATIBLEofficially-verified
Pytes Inverter Compatibility List V.20230819, https://www.pytesess.com/ueditor/php/upload/file/20240705/1720170604646137.pdf (fetched 2026-09-01)
Dyness A48100 COMPATIBLEmanufacturer-documented
Dyness A48100 User Manual section 2.3.1 DIP master-setting table, https://www.ienergy-us.com/uploads/files/A48100%C2%A0User%C2%A0Manual.pdf (fetched 2026-09-01)
BSLBATT B-LFP48-200E (19-inch rack battery, 10.24 kWh) COMPATIBLEmanufacturer-documented
BSLBATT B-LFP48 Rack Battery Pack User Manual V2.7 CAN/RS485 protocol tables, https://bslbatt.com/wp-content/uploads/2024/09/B-LFP48-User-Manual-V2.7-Rack-Battery-Pack.pdf (fetched 2026-09-01)
EG4 LifePower4 48V (v2) COMPATIBLEmanufacturer-documented
EG4 LifePower4 48V V2 & V3 Quick Start Guide protocol tables 11.1/11.2, https://eg4electronics.com/wp-content/uploads/2024/06/EG4-LifePower4-Quick-Start-Guide.pdf (fetched 2026-09-01)
EG4 WallMount Indoor 280Ah (14.3 kWh) COMPATIBLEmanufacturer-documented
EG4 Indoor 280Ah Battery Quick Start Guide protocol tables (p.26-28), https://eg4electronics.com/wp-content/uploads/2024/04/EG4%C2%AE-Indoor-280Ah-Battery-Quick-Start-Guide.pdf (fetched 2026-09-01)
Fortress Power eVault MAX 18.5 kWh COMPATIBLEofficially-verified
Fortress Power Battery Inverter Compatibility Guide, https://www.fortresspower.com/dealers/inverter-compatibility/ (fetched 2026-09-01)

inverter_meter

Carlo Gavazzi EM24 (AV2/AV9 direct; AV5/AV6 CT-input) COMPATIBLEofficially-verified
Victron EM24 FAQ/documentation

inverter_microinverter

Enphase IQ8M COMPATIBLEinferred-from-electrical-parameters
Victron Energy datasheet (ac_coupling_support=true) + Enphase IQ8M datasheet (grid-tie AC output, standard grid-interconnection cert.)
Enphase IQ8+ COMPATIBLEinferred-from-electrical-parameters
Victron Energy datasheet (ac_coupling_support=true) + Enphase IQ8+ datasheet (grid-tie AC output, standard grid-interconnection cert.)
Hoymiles HMS-2000-4T-NA COMPATIBLEinferred-from-electrical-parameters
Victron Energy datasheet (ac_coupling_support=true) + Hoymiles HMS-2000-4T-NA datasheet (grid-tie AC output, standard grid-interconnection cert.)
APsystems QT2-208 COMPATIBLEinferred-from-electrical-parameters
Victron Energy datasheet (ac_coupling_support=true) + APsystems QT2-208 datasheet (grid-tie AC output, standard grid-interconnection cert.)
APsystems DS3 (S/L/base variants) COMPATIBLEinferred-from-electrical-parameters
Victron Energy datasheet (ac_coupling_support=true) + APsystems DS3 (S/L/base variants) datasheet (grid-tie AC output, standard grid-interconnection cert.)
Deye SUN800G3-EU-230 COMPATIBLEinferred-from-electrical-parameters
Victron Energy datasheet (ac_coupling_support=true) + Deye SUN800G3-EU-230 datasheet (grid-tie AC output, standard grid-interconnection cert.)
TSUN TSOL-MX1000 (Gen3) COMPATIBLEinferred-from-electrical-parameters
Victron Energy datasheet (ac_coupling_support=true) + TSUN TSOL-MX1000 (Gen3) datasheet (grid-tie AC output, standard grid-interconnection cert.)
NEP (Northern Electric Power) BDM-800 COMPATIBLEinferred-from-electrical-parameters
Victron Energy datasheet (ac_coupling_support=true) + NEP (Northern Electric Power) BDM-800 datasheet (grid-tie AC output, standard grid-interconnection cert.)

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Cont. output power at 25 C (apparent)5000 VA
Parallel operationup to six identical units in parallel; three-phase maximum five per phase / 15 total
Recommended DC fuse and battery cable (48/5000/70)see manual ch.4.3 table - the 48 V 5 kVA row was not transcribed in this session
Transfer switch / Maximum AC input current50 A