Identity
| category |
inverters
|
| manufacturer |
Victron Energy B.V.
|
| market_version |
230 VAC 50 Hz
|
| model |
Quattro-II 24/5000/120-50/50
|
| product_family |
Quattro-II 230V
|
| product_status |
active
|
| region |
230V / EU
|
| release_year |
UNKNOWN
|
| sku |
UNKNOWN
|
Electrical
| ac_output_frequency |
50 Hz ± 0,1 %
|
| ac_output_voltage |
230 VAC ± 2 %
|
| battery_temperature_sensor |
Yes
|
| charge_voltage_absorption_v |
UNKNOWN
|
| charge_voltage_float_v |
UNKNOWN
|
| charge_voltage_storage_v |
UNKNOWN
|
| cont_output_power_at_25c_va |
UNKNOWN
|
| cont_output_power_at_25c_w |
4000
|
| cont_output_power_at_40c_w |
3700
|
| cont_output_power_at_65c_w |
3000
|
| dc_input_voltage_range |
19 - 33 V
|
| max_battery_charge_current_a |
120
|
| maximum_efficiency_pct |
96
|
| number_of_ac_inputs |
2
|
| peak_power_w |
9000
|
| power_assist |
Yes
|
| power_control |
Yes
|
| system_dc_voltage_v |
24
|
| transfer_switch_a |
50
|
| zero_load_power_in_aes_mode_w |
12
|
| zero_load_power_w |
18
|
Physical / mechanical
| depth_mm |
149
|
| enclosure_material |
Steel, blue RAL 5012
|
| height_mm |
607
|
| mounting_type |
['wall-mount']
|
| terminal_locations |
UNKNOWN
|
| torque_specs |
Battery terminal M8 nut: 12 Nm (shared MultiPlus-II/Quattro-II manual)
|
| weight_kg |
31
|
| width_mm |
329
|
Installation
| minimum_clearance |
at least 10cm for ventilation purposes under, above and beside the units
|
| recommended_dc_cable_cross_section |
UNKNOWN
|
Environment
| altitude |
UNKNOWN
|
| cooling |
UNKNOWN
|
| humidity |
max 95 % (non-condensing)
|
| ip_rating |
IP21
|
| operating_temperature_range |
-40 to +65 °C
|
Interfaces & connectors
| bluetooth |
UNKNOWN
|
| ethernet |
UNKNOWN
|
| modbus |
UNKNOWN
|
| relay |
Programmable relay: Yes
|
| ve_bus |
Yes
|
| ve_can |
UNKNOWN
|
| ve_direct |
UNKNOWN
|
Protection
| list |
['output short circuit', 'overload', 'battery voltage too high', 'battery voltage too low', 'temperature too high', '230 VAC on inverter output', 'input voltage ripple too high']
|
Certifications
| standards |
['EN-IEC 60335-1', 'EN-IEC 60335-2-29', 'EN-IEC 62109-1', 'EN-IEC 62109-2']
|
Documents
dimensional-drawing
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Quattro-II 24V 5000VA 230V enclosure dimensions — located, not retrieved
rev UNKNOWN