Jinko Solar JKM665N-66QL6-BDV-AntiGlare
Official manufacturer GLOBAL verified Sept. 3, 2026
Identity
| category | pv_modules |
| generation | Tiger Neo 3.0 |
| manufacturer | Jinko Solar |
| market_version | IEC 1500 V |
| model | JKM665N-66QL6-BDV-AntiGlare |
| mpn | UNKNOWN |
| product_family | JKM645-665N-66QL6-BDV-AntiGlare (Tiger Neo 3.0, bifacial dual glass, anti-glare front glass) |
| product_status | active |
| region | GLOBAL |
| release_year | UNKNOWN |
| series | 66QL6-BDV-AntiGlare |
| sku | UNKNOWN |
| variant | Anti-Glare front glass (2.0 mm Anti-Glare Glass instead of anti-reflection coated glass) |
Electrical
| application_class | UNKNOWN |
| bifacial | True |
| bifaciality_factor_pct | 85 |
| cell_technology | N-type Mono-crystalline (datasheet wording); 264 quarter cells (66x4); bifacial dual glass with anti-glare front glass |
| extra | {'power_bins_w': [645, 650, 655, 660, 665], 'power_bin_table': [{'pmax_w': 645, 'model': 'JKM645N-66QL6-BDV-AntiGlare', 'voc_v': 49.88, 'vmp_v': 42.27, 'isc_a': 15.98, 'imp_a': 15.26, 'efficiency_pct': 23.88}, {'pmax_w': 650, 'model': 'JKM650N-66QL6-BDV-AntiGlare', 'voc_v': 50.26, 'vmp_v': 42.57, 'isc_a': 15.98, 'imp_a': 15.27, 'efficiency_pct': 24.06}, {'pmax_w': 655, 'model': 'JKM655N-66QL6-BDV-AntiGlare', 'voc_v': 50.44, 'vmp_v': 42.7, 'isc_a': 16.04, 'imp_a': 15.34, 'efficiency_pct': 24.25}, {'pmax_w': 660, 'model': 'JKM660N-66QL6-BDV-AntiGlare', 'voc_v': 50.5, 'vmp_v': 42.78, 'isc_a': 16.14, 'imp_a': 15.43, 'efficiency_pct': 24.43}, {'pmax_w': 665, 'model': 'JKM665N-66QL6-BDV-AntiGlare', 'voc_v': 50.55, 'vmp_v': 42.85, 'isc_a': 16.24, 'imp_a': 15.52, 'efficiency_pct': 24.62}], 'bnpi_table': [{'pmax_w': 718, 'voc_v': 50.0, 'vmp_v': 42.15, 'isc_a': 17.79, 'imp_a': 17.04}, {'pmax_w': 724, 'voc_v': 50.38, 'vmp_v': 42.52, 'isc_a': 17.8, 'imp_a': 17.04}, {'pmax_w': 729, 'voc_v': 50.56, 'vmp_v': 42.69, 'isc_a': 17.87, 'imp_a': 17.1}, {'pmax_w': 735, 'voc_v': 50.7, 'vmp_v': 42.7, 'isc_a': 17.98, 'imp_a': 17.21}, {'pmax_w': 741, 'voc_v': 50.75, 'vmp_v': 42.75, 'isc_a': 18.09, 'imp_a': 17.32}], 'bnpi_conditions': 'BNPI: front 1000 W/m2, rear 135 W/m2, 25 degC, AM1.5', 'cell_count': '264 (66x4)', 'cell_layout': '66x4 quarter cells', 'fire_type': 'IEC Fire Type Class C', 'operating_temperature_class': 'Level T98 <= 70 degC', 'bifaciality_coefficients': 'Bifacial Factor 85+-5%; phiVoc: 98+-5 %, phiIsc: 85+-5 %, phiPmax: 85+-5 %', 'bifacial_gain_note': 'UNKNOWN'} |
| imp_a | 15.52 |
| isc_a | 16.24 |
| max_reverse_current_a | UNKNOWN |
| max_series_fuse_rating_a | 35 |
| max_system_voltage_label | 1500 VDC (IEC) |
| max_system_voltage_v | 1500 |
| module_efficiency_pct | 24.62 |
| nmot | {'pmax_w': 'UNKNOWN', 'voc_v': 'UNKNOWN', 'vmp_v': 'UNKNOWN', 'isc_a': 'UNKNOWN', 'imp_a': 'UNKNOWN', 'conditions': 'UNKNOWN', 'note': "No NMOT/NOCT table printed. Datasheet prints 'Level T98 <= 70 degC' instead."} |
| nmot_c | UNKNOWN |
| pmax_w | 665 |
| power_tolerance | UNKNOWN |
| protection_class | Class II |
| rated_power_w | 665 |
| stc_conditions | STC: 1000 W/m2, AM1.5, cell temperature 25 degC |
| temp_coeff_isc | 0.046 %/degC |
| temp_coeff_pmax | -0.26 %/degC |
| temp_coeff_voc | -0.24 %/degC |
| vmp_v | 42.85 |
| voc_v | 50.55 |
Physical / mechanical
| backsheet | not applicable - dual glass |
| bypass_diodes | UNKNOWN |
| cable_cross_section_mm2 | 4.0 |
| cable_length_mm | (+): 500 mm, (-): 400 mm or Customized Length |
| connector_type | JK03M / JK03M2 / Others (MC4-EVO2 available upon request) |
| depth_mm | 30 |
| dimensions_mm | 2382x1134x30 |
| frame | Anodized Aluminium Alloy |
| frame_colour | UNKNOWN |
| glass | Front: 2.0 mm Anti-Glare Glass; Back: 2.0 mm Heat Strengthened Glass |
| glass_construction | dual glass |
| glass_thickness_mm | 2.0 |
| junction_box | IP68 Rated |
| length_mm | 2382 |
| weight_kg | 32.5 |
| width_mm | 1134 |
Installation
| clamp_requirements | Length of the clamp (a) >= 50 mm, thickness >= 3 mm, frame overlap (d) 10-11 mm, torque 16-20 Nm (M8 bolt) |
| grounding | 4 mm grounding holes on the long side of the back frame; copper AWG 6-12 (4-14 mm2) |
| max_installation_altitude_m | 2000 |
| mounting_methods | Fixed installation with bolts, fixed installation with clamps, tracker installation (JinkoSolar Global Installation Manual) |
Environment
| ammonia | IEC62716 listed among certifications |
| fire_rating | IEC Fire Type Class C |
| hail | UNKNOWN |
| max_static_load_front_pa | 5400 |
| max_static_load_rear_pa | 2400 |
| operating_temperature_c | -40 to +70 |
| pid | IEC62804 listed among certifications |
| salt_mist | IEC61701 listed among certifications |
| snow_load | UNKNOWN |
| wind_load | UNKNOWN |
Certifications
| standards | ['IEC61215:2021', 'IEC61730:2023', 'IEC61701', 'IEC62716', 'IEC60068', 'IEC62804', 'ISO9001:2015', 'ISO14001:2015', 'ISO45001:2018'] |
Warranty & service
| annual_degradation_pct | 0.35 |
| first_year_degradation_pct | 1.0 |
| performance_years | 30 |
| product_years | 12 |
| retained_power_at_year | 30 |
| retained_power_end_pct | 88.85 |
Documents
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Antiglare feature | Significant reduction on glare intensity and ideal for common glare scenarios such as airports and residential areas, etc. |
| Bifaciality Coefficents | φVoc: 98±5 %, φIsc: 85±5 %, φPmax: 85±5 % |
| Power Measurement Tolerance | ±3% |
| manufacturer_legal_entity_as_printed | Jinko Solar Co., Ltd. |