BSLBATT B-LFP48-100E (3U Server Rack Battery)
Official manufacturer Global verified Aug. 31, 2026
UNKNOWN
Identity
| category | batteries |
| ean | UNKNOWN |
| generation | UNKNOWN |
| manufacturer | BSLBATT |
| market_version | UNKNOWN |
| model | B-LFP48-100E (3U Server Rack Battery) |
| mpn | B-LFP48-100E |
| product_family | B-LFP48-E rack series (52E/100E/104E/134E/156E/174E/200E/280E/300E) |
| product_revision | UNKNOWN |
| product_status | active |
| region | Global |
| release_year | UNKNOWN |
| sku | UNKNOWN |
Electrical
| bms_architecture | {'type': 'master/slave over RS485B; address 1 = master, addresses 2-63 = slaves, address 0 for single-unit use', 'separate_master_bmu_required': False, 'address_setting': '6-bit DIP dial switch (#1-#6)', 'modules_per_stack': 'UNKNOWN', 'max_parallel_groups': 'user manual V2.7 states max 15 parallel; the manufacturer product pages state up to 63 - see data_conflicts'} |
| chemistry | LFP (LiFePO4, cobalt-free) |
| communication_can | True |
| communication_rs485 | True |
| firmware_requirements | UNKNOWN (OTA updates available via BSLBATT app) |
| max_continuous_charge_current_a | 80 |
| max_continuous_discharge_current_a | 100 |
| max_continuous_power_kw | 5.12 |
| max_parallel_units | 63 |
| max_series_units | N/A (LV parallel stack) |
| min_series_units_hv | N/A |
| nominal_energy_kwh | 5.12 |
| nominal_voltage_v | 51.2 |
| officially_supported_inverter_brands | ['Victron', 'Deye', 'Growatt', 'SMA', 'GoodWe', 'Solis', 'Schneider', 'Sofar'] |
| officially_supported_inverter_models | UNKNOWN (brand-level only; manufacturer claims 30+ brands total). Default CAN ships set to Victron; default RS485 set to Pylontech-emulation, both user-configurable. |
| peak_current_a | 150 |
| protocol_dialects | {'values': ['CAN 500 Kb/s (isolated dual) - inverter link; selectable dialects: Pylon, DEYE/Sunsynk, Growatt, Victron, Luxpower, SMA, Goodwe, Studer, Sofar, Ginlong/Solis, TBB_LITHIUM, Daneng, Aiswei, SAJ, MUST, Megarevo, Afore', 'RS485A 9600 bps - monitoring / external equipment; selectable dialects: Pylon, DEYE/Sunsynk, Growatt, Voltronic, Phocos, Luxpower, WOW, Sorotec, Hypon, Afore', 'RS485B 9600 bps - parallel battery communication only', 'RS232 9600 bps (RJ11) - host PC software and firmware update', 'Factory default: CANBUS = Victron, RS485 = DEYE', 'Wi-Fi and Bluetooth (per official product page)'], 'note': 'Verbatim inverter-protocol dialect list from the manufacturer document. The flat supported_inverter_protocols field keeps the coarse physical-layer list that downstream consumers parse.', 'evidence': "BSLBATT B-LFP48 user manual V2.7 fetched 2026-09-01. Verbatim CAN protocol list: 'Pylon, DEYE/Sunsynk, Growatt, Victron, Luxpower, SMA, Goodwe, Studer, Sofar, Ginlong/Solis, TBB_LITHIUM, Daneng, Aiswei, SAJ, MUST, Megarevo, Afore'; RS485 list: 'Pylon, DEYE/Sunsynk, Growatt, Voltronic, Phocos, Luxpow"} |
| supported_inverter_protocols |
['RS232', 'RS485', 'CAN', 'Wi-Fi', 'Bluetooth']
Rack Battery Pack User Manual B-LFP48 V2.7 (52/100/104/134/156/174/200/280/300E) — user manual V2.7 CAN/RS485 protocol brand tables; 'Default Setting: CANBUS - Victron, RS485-DEYE'
|
| usable_energy_kwh | 4.864 |
| voltage_class | LV |
| voltage_range_v | 44.8-56.4 |
Physical / mechanical
| depth_mm | 538 |
| height_mm | 136 |
| mounting_bolt_size | UNKNOWN (screw-based cabinet installation with nuts) |
| mounting_type | ['rack', 'floor'] |
| rack_units | 3U |
| shipping_weight_kg | UNKNOWN |
| terminal_locations | front panel P+ / P- terminals, breaker, comm ports, 6-bit DIP switch |
| torque_specs | UNKNOWN (not printed in user manual V2.7) |
| weight_kg |
53
Rack Battery Pack User Manual B-LFP48 V2.7 (52/100/104/134/156/174/200/280/300E) — user manual V2.7 model table, '100E 53 kg, 538x442x136 mm'
|
| width_mm | 442 |
Installation
| commissioning_note | cell imbalance is flagged when the cell voltage difference exceeds 1 V |
| indoor_outdoor | indoor |
| surface_requirements | load-bearing plate, minimum 15 cm clearance from ground; unit spacing ~205 mm |
Environment
| charge_temperature_c |
0 to +55
Rack Battery Pack User Manual B-LFP48 V2.7 (52/100/104/134/156/174/200/280/300E) — user manual V2.7 environmental table
|
| cooling_method | natural convection |
| discharge_temperature_c | -20 to +55 |
| ip_rating | IPX4 (user manual V2.7); the 200E product page states IP20 for the same family |
| max_altitude_m | UNKNOWN |
| relative_humidity | UNKNOWN |
| storage_temperature_c | 0 to +35 (recommended) |
Interfaces & connectors
| battery_terminal_type | P+ / P- power terminals |
| bluetooth | yes |
| can | yes - 500 Kb/s; RJ45 pin4 CAN-H, pin5 CAN-L, pin7 GND |
| dry_contacts |
yes - dry-contact relay: pins 1-2 close on fault/protection, pins 3-4 close on low-SOC alarm
Rack Battery Pack User Manual B-LFP48 V2.7 (52/100/104/134/156/174/200/280/300E) — user manual V2.7 dry-contact relay pin table
|
| rs232 | yes - RJ11, pin3 TX, pin4 RX, pin5 GND, 9600 bps |
| rs485 | yes - RS485A (monitoring) and RS485B (parallel), 9600 bps; RS485B RJ45 pins 1/8 = B, 2/7 = A, 3/6 = GND |
| wifi | yes |
Protection
| cell_balancing | cell imbalance detected when cell voltage difference > 1 V |
| integrated_breakers_fuses | manual ON/OFF DC breaker on the front panel; rating not printed |
| over_current | yes |
| over_temperature | yes - triggers shutdown |
| over_voltage | yes (overcharge) |
| reverse_polarity | yes - reverse connection detected, operation halted |
| short_circuit | yes |
| under_voltage | yes |
Warranty & service
| design_life_years | >15 (@25 C) |
| self_discharge | UNKNOWN |
| standard_years | 10 |
Packaging & logistics
| gross_weight_kg | UNKNOWN |
| transport_restrictions | UNKNOWN (no UN38.3 or Class 9 statement in user manual V2.7) |
Documents
user-manual
Rack Battery Pack User Manual B-LFP48 V2.7 (52/100/104/134/156/174/200/280/300E)
rev V2.7
Recorded conflicts
max_parallel_units Review required
63 — bsl-battery.com product pages (existing record source, 2026-08-31; re-confirmed on the 200E page 2026-09-01)
15 — B-LFP48 user manual V2.7 (2024-09), 'Max Parallel Units 15 (Address range 2-63)'
the manual limit appears to be per communication group while the 6-bit address space allows 63
max_parallel_units Review required
63 — bsl-battery.com product pages (existing record source, 2026-08-31; re-confirmed on the 200E page 2026-09-01)
15 — B-LFP48 user manual V2.7 (2024-09), 'Max Parallel Units 15 (Address range 2-63)'
the manual limit appears to be per communication group while the 6-bit address space allows 63
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Cell configuration | 16S1P to 16S3P (varies by capacity) |
| Storage maintenance | charged every three months, and the SOC should be no less than 30%; recharge within 12 hours after fully discharging |