Pylontech Force H3 (FH10050 module stack)
Manufacturer documented EU/global verified Sept. 1, 2026
UNKNOWN
Identity
| category | batteries |
| ean | UNKNOWN |
| generation | H3 |
| manufacturer | Pylontech (Pylon Technologies Co., Ltd.) |
| market_version | UNKNOWN |
| model | Force H3 (FH10050 module stack) |
| mpn | FH10050 |
| note | Pylontech's HV compatibility list treats Force-H1, Force-H1-V2, Force-H2, Force-H2-V2, Force-H3 and Powercube-M1C/M5 as separate, non-interchangeable products; several inverters accept only the -V2 revisions or only Force-H3. |
| product_family | Force H3 (successor to Force H1 / Force H2 / Force-H2-V2) |
| product_revision | UNKNOWN |
| product_status | active |
| region | EU/global |
| release_year | UNKNOWN |
| sku | FH10050 (module) |
Electrical
| chemistry | LFP (LiFePO4) |
| communication_can | True |
| communication_rs485 | True |
| firmware_requirements | Compatibility List of Pylontech High Voltage ESS and Inverters Ver.2.40 (2025-08-15): Deye SG01HP3 requires inverter FW 2001-X018; Sungrow SH-RT requires SAPPHIRE-H_V11_V01_A; SMA SBSE requires 04.04.03.R / 3.12.15.R and battery BMS >= 1.6; Sofar HYD TL-3PH requires FW D0110036 and DSP V010027. Disclaimer: 'Compatibility testing with various inverter brands is currently underway. The list will be updated regularly.' |
| max_continuous_charge_current_a |
50
Pylontech Force H3 datasheet — 'Charge/discharge current 50 A (normal); 55@15MIN (max)'
|
| max_continuous_discharge_current_a | 50 |
| max_continuous_power_kw | UNKNOWN (varies with stack voltage; not stated) |
| max_parallel_units |
6
Pylontech Force H3 datasheet — 'Max 6 groups in parallel'
|
| max_series_units |
7
Pylontech Force H3 datasheet — 'Modules per stack 2-7 pcs'
|
| min_series_units_hv | 2 |
| nominal_energy_kwh | 10.24-35.84 (2-7 modules of 5.12 kWh) |
| nominal_voltage_v | 102.4 per module; system 204.8 (2 modules) to 716.8 (7 modules) |
| officially_supported_inverter_brands | ['Deye (Sunsynk)', 'Kostal', 'Sungrow', 'GoodWe', 'Solis', 'SMA', 'Sofar'] |
| officially_supported_inverter_models |
['Deye (Sunsynk) SUN-5~25K-SG01HP3-EU/AU - FH3 2-6 modules, CAN, on/off-grid, inverter FW 2001-X018', 'Deye (Sunsynk) SUN-29.9~50K-SG01HP3-EU/AU - FH3 2-7 modules, CAN, inverter FW 2001-X018', 'Kostal PLENTICORE plus / plus G2 / BI xx/26 / BI xx/26 G2 / PLENTICORE G3 - FH3 2-4 (plus) or 2-5 (G2/G3/BI), RS485', 'Sungrow SH5.0/6.0/8.0/10.0RT - FH3 2-5, CAN, inverter FW SAPPHIRE-H_V11_V01_A', 'GoodWe EH/BH series - FH3 2-4, CAN', 'GoodWe ET 5-10 - FH3 2-5, CAN', "GoodWe ET 15-30 and ET 40~50 - FH3 3-7, CAN ('Only Force-H3 and Powercube-M1C are compatible with Goodwe ET 15~30KW/40KW/50KW')", 'GoodWe ET G2 series - FH3 2-6, CAN', 'Solis RHI-3P-HVES-5G series - FH3 2-5', 'Solis S6-EH3P(5-10)K-H-EU - FH3 2-5', 'Solis S6-EH1P(3.8-11.4)K-H-US - FH3 2-4', 'Solis S6-EH3P(12-20)K-H - FH3 2-7', 'Solis S6-EH3P(29.9-50)K-H and S6-EH3P(30-60)K-H-US - FH3 2-7', "SMA SBSE3.6/4.0/5.0/6.0/8.0/9.9-50 - FH3 2-4, CAN, 'Force-H3 only (BMS >= 1.6)', inverter FW 04.04.03.R / 3.12.15.R", 'Sofar HYD 10000/15000/20000 TL-3PH - FH3 2-7, CAN, FW D0110036 / DSP V010027']
Compatibility List of Pylontech High Voltage ESS and Inverters Ver.2.40 — HV ESS compatibility matrix rows
|
| peak_current_a | 55 for 15 min (datasheet '55@15MIN') |
| supported_inverter_protocols | ['CAN', 'Modbus RTU', 'RS485'] |
| usable_energy_kwh | 9.73-34.05 (95 % of nominal per datasheet 'usable capacity 95%') |
| voltage_class | HV |
| voltage_range_v | UNKNOWN exact min-max window (datasheet prints nominal per stack size 204.8-716.8 V but no operating window) |
Physical / mechanical
| depth_mm | 350 |
| height_mm | 530-1380 (varies with 2-7 modules) |
| module_energy_kwh | 5.12 |
| module_nominal_voltage_v | 102.4 |
| mounting_type | ['floor', 'wall'] |
| shipping_weight_kg | UNKNOWN |
| stack_dimensions_by_size_mm | 540 W x 350 D x 530-1380 H depending on module count |
| torque_specs | UNKNOWN |
| weight_kg | 92-287 (varies with stack size) |
| width_mm | 540 |
Installation
| indoor_outdoor | IP55 - indoor/outdoor per installation rules |
| installation_method_note | Pylontech HV compatibility list carries an 'Installation method' column with values 'Wall mounting' / 'Cabinet' per inverter pairing |
| max_installation_altitude_m | 4000 |
| maximum_modules_per_stack | 7 |
| maximum_stacks_in_parallel | 6 |
| minimum_modules_per_stack | 2 |
| mounting_orientation | upright stack |
| orientation_allowed | ['floor (cabinet)', 'wall mounting'] |
| parallel_rules | 'Max 6 groups in parallel'. Datasheet footnote: 'Only up to 6 modules per stack when connected to the Ferroamp-system'. The Pylontech HV compatibility list further constrains the module count per inverter model (see officially_supported_inverter_models). |
Environment
| charge_temperature_c | -10 to +55 |
| cooling_method | natural convection (no fan documented) |
| discharge_temperature_c | UNKNOWN (datasheet prints one range labelled for charge) |
| ip_rating | IP55 |
| max_altitude_m | 4000 |
| noise_level_db | UNKNOWN |
| operating_temperature_c | -10 to +55 (charge, per datasheet '-10~55') |
| relative_humidity | 5 % - 95 % no condensation |
| storage_temperature_c | -20 to +45 |
Interfaces & connectors
| bluetooth | UNKNOWN |
| can | yes (CAN to inverter) |
| dry_contacts | UNKNOWN |
| ethernet | UNKNOWN |
| modbus_rtu | True |
| protocol_notes | datasheet 'Communication: Modbus RTU/CAN'. Pylontech's HV list records the protocol used per inverter (CAN for Deye/Sungrow/GoodWe/Solis/SMA/Sofar; RS485 for Kostal PLENTICORE). |
| rs485 | yes |
| wifi | UNKNOWN |
Controls & display
| buttons | UNKNOWN |
| display_type | UNKNOWN |
| leds | UNKNOWN |
| local_display | UNKNOWN |
| mobile_app | UNKNOWN |
Protection
| integrated_breakers_fuses | UNKNOWN |
| integrated_dc_switch | UNKNOWN |
| over_current | UNKNOWN |
| over_temperature | UNKNOWN |
| over_voltage | UNKNOWN |
| short_circuit | UNKNOWN |
| thermal_runaway_measures | UNKNOWN (UL 9540A tested per certification list) |
| under_voltage | UNKNOWN |
Certifications
| emc | [] |
| grid_codes | ['VDE-AR-E 2510-50'] |
| other | ['UL9540A', 'UN38.3'] |
| regional | [] |
| safety | ['IEC62040-1', 'IEC62477-1', 'IEC62619', 'IEC63056', 'UL1973'] |
Warranty & service
| conditions | UNKNOWN |
| cycle_life | > 8,000 cycles at 25 C |
| design_life_years | 15+ years at 25 C |
| standard_years | UNKNOWN (datasheet gives design life, not a warranty term) |
| throughput_guarantee_mwh | UNKNOWN |
Packaging & logistics
| gross_weight_kg | UNKNOWN |
| transport_restrictions | UN38.3 certified (certification list) |
Documents
compatibility-list
Compatibility List of Pylontech High Voltage ESS and Inverters Ver.2.40
rev Ver.2.40
installation-manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Lithium Phosphate Energy Storage System Force-H3 Operation Manual — located, not retrieved
rev UNKNOWN
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| Activation & Force Charge | Yes/No column per inverter pairing |
| Installation method | Wall mounting / Cabinet, per inverter pairing |
| Only up to 6 modules per stack when connected to the Ferroamp-system | 6 modules max with Ferroamp |