Pylontech US5000
Official manufacturer Global verified Sept. 1, 2026
UNKNOWN
Identity
| category | batteries |
| ean | UNKNOWN |
| generation | UNKNOWN |
| manufacturer | Pylontech |
| market_version | UNKNOWN |
| model | US5000 |
| mpn | UNKNOWN |
| product_family | US5000 series (US5000 / US5000-B) |
| product_revision | UNKNOWN |
| product_status | active |
| product_status_detail | active (listed on en.pylontech.com.cn product pages as of 2026-09-01) |
| region | Global |
| release_year | UNKNOWN |
| sku | UNKNOWN |
Electrical
| bms_architecture | {'type': 'distributed master/slave; the first module (Link Port 0 left empty) is master, up to 15 slaves', 'separate_master_bmu_required': False, 'external_controller': 'LV-HUB required only for multi-group CAN operation', 'modules_per_stack': '16 per battery group', 'max_parallel_groups': 'UNKNOWN (multi-group supported via LV-HUB; count not printed in this manual)'} |
| chemistry | LFP (LiFePO4) |
| communication_can | True |
| communication_rs485 | True |
| firmware_requirements | UNKNOWN |
| max_continuous_charge_current_a |
100
US5000 product page - Technical Specifications — product page spec table, 'Charge/Discharge (A) (Normal) 100'
|
| max_continuous_discharge_current_a | 100 |
| max_continuous_power_kw | UNKNOWN (no kW figure printed in datasheet, operation manual or official product page) |
| max_parallel_units |
16
Rechargeable Li-ion Battery US5000 series Operation Manual — operation manual p.6, 'Configuration (max. in 1 battery group) 16pcs'; master priority US5000>UP5000/US3000C/US2000C>US3000/US2000
|
| max_series_units | N/A (series connection explicitly forbidden - manual p.4 'Do NOT connect battery in series') |
| min_series_units_hv | N/A |
| nominal_energy_kwh | 4.8 |
| nominal_voltage_v | 48 |
| officially_supported_inverter_brands | UNKNOWN (operation manual refers only to 'inverter on compatible list' (p.28); the compatible-inverter list itself was not fetched this session) |
| officially_supported_inverter_models | ['Deye SUN-3.6/5/6/7.6/8K-SG01LP1-EU, SUN-5/6/7.6/8K-SG01LP1-US, SUN-3.6/5/6K-SG03LP1-EU, SUN-3/3.6/5/6K-SG04LP1-EU, SUN-3.6/5/6/7.6/8K-SG05LP1-EU, SUN-5/6/8/10/12K-SG04LP3-EU, SUN-12/14/16K-SG01LP1-EU (per Deye Approved Battery List DY-LV48-0109, battery setup 00, CAN)'] |
| peak_current_a |
121-200 @15s (and 101-120 @15min); official product page label 'Charge/Discharge (A) (Peak) 121-200 @15s'
US5000 product page - Technical Specifications — product page spec table, 'Charge/Discharge (A) (Peak) 121-200 @15s'
|
| supported_inverter_protocols | ['CAN 500 kbps, 120 ohm (RJ45 pin4 CAN-H, pin5 CAN-L, pin6 CAN-GND) - Pylontech native CAN', 'RS485 9600 or 115200 bps, 120 ohm (RJ45 pin7 485A, pin8 485B) - Pylontech native RS485', 'RS232 console (pin3 232-TX, pin6 232-RX, pin8 232-GND) - service/debug only'] |
| usable_energy_kwh | 4.56 |
| voltage_class | LV |
| voltage_range_v | 43.5-53.5 (discharge window); charge window 52.5-53.5 |
Physical / mechanical
| depth_mm | 420 |
| enclosure_material | UNKNOWN |
| height_mm | 161 |
| housing_color | UNKNOWN |
| mounting_bolt_size | UNKNOWN |
| mounting_hole_spacing_mm | UNKNOWN |
| mounting_type | ['rack', 'floor'] |
| rack_units | UNKNOWN (official page states '19 inch Rack Compatible'; no U figure printed. 161 mm ~ 3.6U) |
| screw_sizes | 4 screws per module for cabinet fixing (manual p.21) |
| shipping_weight_kg | UNKNOWN |
| terminal_locations | front panel: power terminals, RS232 console, RS485 x2, CAN, Link Port 0/1, DIP switch, ground stud |
| torque_specs | UNKNOWN (not documented in the operation manual) |
| weight_kg | 39.7 |
| width_mm |
442
US5000 product page - Technical Specifications — product page, 'Dimension (W*D*H mm) 442*420*161'
|
Installation
| clearance_note | UNKNOWN |
| indoor_outdoor | indoor (IP20) |
| max_installation_altitude_m | 4000 |
| max_stack_units | 3 modules maximum when stacked on brackets without a cabinet (manual p.22) |
| mounting_orientation | horizontal rack module |
Environment
| charge_temperature_c | 0 to +55 (official product page) / 0 to +50 (operation manual) |
| cooling_method | natural convection (no fan documented) |
| discharge_temperature_c | -10 to +55 (official product page) / -10 to +50 (operation manual) |
| ip_rating | IP20 |
| max_altitude_m | 4000 |
| noise_level_db | UNKNOWN |
| operating_temperature_c | charge 0 to +55, discharge -10 to +55 (official product page); optimal 10-40 (manual p.18) |
| relative_humidity | 5%-95% RH, no condensation |
| storage_temperature_c | -20 to +45 (official product page) / -20 to +60 (operation manual 'shelf temperature') |
Interfaces & connectors
| battery_terminal_type | self-locked power connectors; supplied cable kit 2 x 210 mm 4 AWG power cables, 1 x 210 mm RJ45 comm cable, 1 x 1000 mm 6 AWG grounding cable (manual p.16); external kit 2 x 2000 mm 4 AWG (peak 120 A, constant 100 A) (p.17) |
| can | yes - 500 kbps, 120 ohm; DIP2 selects CAN terminal resistance |
| dry_contacts | UNKNOWN |
| protocol_notes | Battery-to-inverter cable WI0SCAN30RJ1 (blue mark) leaves pins 1-3 empty; battery-to-battery cable WI0SCAN35RJ3 (silver mark) is pin-to-pin 1-8. Multi-group CAN operation uses the Pylontech LV-HUB. |
| rs232 | yes - console port |
| rs485 | yes - 2 x RJ45, 9600 or 115200 bps (DIP1 selects), 120 ohm recommended |
Protection
| cell_balancing | UNKNOWN (not stated in the operation manual) |
| external_disconnect_requirement |
DC breaker >=60 VDC (never an AC breaker), Type C or D; with a single pair of 4 AWG cables the breaker must be <=125 A; Icu >=10 kA for 1-4 modules, >=20 kA for 5-8 modules (manual p.23)
Rechargeable Li-ion Battery US5000 series Operation Manual — operation manual p.23
|
| integrated_breakers_fuses |
US5000-B only: Type C DC breaker, rated 60 VDC / 125 A, Icu 10 kA, to UL1077 and IEC 60947-2. Base US5000 has none.
Rechargeable Li-ion Battery US5000 series Operation Manual — operation manual, US5000-B breaker spec (Type C, 60V/DC, 125A, Icu 10kA, UL1077/IEC60947-2)
|
| over_current | yes (charge and discharge over-current) |
| over_temperature | yes (high/low temperature protection) |
| over_voltage | yes (BMS over-charge protection) |
| reverse_polarity | UNKNOWN |
| short_circuit | yes; short-circuit current <2000 A / 1 ms (manual p.8) |
| under_voltage | yes (BMS over-discharge protection) |
Certifications
| emc | ['IEC 61000-6-2', 'IEC 61000-6-3'] |
| other | ['TUV Rheinland Safety', 'TUV SUD Safety', 'CSA Safety', 'WEEE Directive 2012/19/EU'] |
| regional | ['CE', 'UKCA'] |
| safety |
['IEC 62619', 'IEC 63056', 'UL 1973', 'UL 9540A']
US5000 product page - Technical Specifications — product page, 'Certification UL1973/UL9540A/IEC62619/IEC63056/IEC61000-6-2/3/UN38.3'
|
| transport | ['UN38.3'] |
Warranty & service
| conditions | UNKNOWN |
| cycle_life | >8,000 (@25 C) per official product page; >6,000 (@25 C) per operation manual p.7 and the Energy S.p.A. datasheet - see data_conflicts |
| design_life_years | 15+ (@25 C) |
| standard_years | 10 (Energy S.p.A. distributor datasheet) |
Packaging & logistics
| gross_weight_kg | UNKNOWN |
| transport_restrictions | UN38.3 tested. Class 9 / UN3480 handling not explicitly stated in the operation manual. |
Documents
Recorded conflicts
max_continuous_charge_current_a Review required
100 A ('Normal') — official product page
80 A recommended at 10-40 C, 100 A max continuous — Operation Manual p.7; Energy S.p.A. datasheet gives 'Recommended Charge Current 80*'
the manual/datasheet split 'recommended' from 'max continuous'; the product page collapses them into 'Normal'
environment.storage_temperature_c Review required
-20 to +45 C — official product page
-20 to +60 C — Operation Manual (labelled 'shelf temperature')
different label semantics (storage vs shelf) and/or document revision
environment.charge_temperature_c Review required
0 to +55 C — official product page, accessed 2026-09-01
0 to +50 C — US5000 series Operation Manual
document revision
warranty.cycle_life Review required
>8,000 @25C — official product page en.pylontech.com.cn/products/us5000, accessed 2026-09-01
>6,000 @25C — US5000 series Operation Manual p.7; Energy S.p.A. datasheet FL065 Rev.001
cell upgrade / newer document revision; the product page is the more recent source
max_continuous_charge_current_a Review required
100 A ('Normal') — official product page
80 A recommended at 10-40 C, 100 A max continuous — Operation Manual p.7; Energy S.p.A. datasheet gives 'Recommended Charge Current 80*'
the manual/datasheet split 'recommended' from 'max continuous'; the product page collapses them into 'Normal'
environment.storage_temperature_c Review required
-20 to +45 C — official product page
-20 to +60 C — Operation Manual (labelled 'shelf temperature')
different label semantics (storage vs shelf) and/or document revision
environment.charge_temperature_c Review required
0 to +55 C — official product page, accessed 2026-09-01
0 to +50 C — US5000 series Operation Manual
document revision
warranty.cycle_life Review required
>8,000 @25C — official product page en.pylontech.com.cn/products/us5000, accessed 2026-09-01
>6,000 @25C — US5000 series Operation Manual p.7; Energy S.p.A. datasheet FL065 Rev.001
cell upgrade / newer document revision; the product page is the more recent source
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| DIP switch functions | Dip1 RS485 baud rate; Dip2 CAN terminal resistance; Dip3-4 reserved |
| Master priority in a mixed-model string | US5000>UP5000/US3000C/US2000C>U3000/US2000 |
| Short current/duration time (A) | <2000/1ms |
| Slave slot restriction | Slaves 9-16 may only be US5000/UP5000/US3000C/US2000C |
| identity.product_status | active (listed on en.pylontech.com.cn product pages as of 2026-09-01) |