Knowledge Base ›
Batteries
Verified distributor
GLOBAL
verified Sept. 22, 2026
PRODUCT PHOTO
Identity
| brand |
Pytes
|
| category |
batteries
|
| ean |
—
|
| firmware |
{'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'}
|
| generation |
—
|
| manufacturer |
Pytes
|
| manufacturer_key |
pytes
|
| market_version |
Low-voltage 48 V rack battery
|
| model |
V5°α Plus
|
| model_key |
v5plus
|
| mpn |
—
|
| product_family |
V Series
|
| product_status |
active
|
| region |
GLOBAL
|
| release_year |
—
|
| series |
V5
|
| sku |
—
|
| variant |
α Plus
|
Electrical
| bms |
—
|
| cell_chemistry |
LFP
|
| cell_configuration |
—
|
| communication |
RS485, CAN, Dry Contact, WiFi
|
| cycle_life |
6000
|
| depth_of_discharge_pct |
90.0
|
| expandable_to_kwh |
—
|
| max_charge_current_a |
50
|
| max_charge_power_w |
—
|
| max_discharge_current_a |
75
|
| max_discharge_power_w |
—
|
| modules_per_stack |
—
|
| nominal_energy_kwh |
5.12
|
| nominal_voltage_v |
51.2
|
| parallel_units_max |
16 (maximum of 16 batteries)
|
| peak_discharge |
—
|
| round_trip_efficiency_pct |
—
|
| usable_energy_kwh |
—
|
| voltage_range_v |
47.5V~57.6V
|
Physical / mechanical
| ac_terminal |
—
|
| cooling |
—
|
| dc_connector |
—
|
| depth_mm |
—
|
| dimensions_mm |
484±2 x 578.2±2 x 140±2 (3.2U)
|
| display |
—
|
| enclosure_material |
—
|
| height_mm |
—
|
| mounting |
19-inch rack
|
| noise_db |
—
|
| weight_kg |
45.34 kg / 100lbs
|
| width_mm |
—
|
Installation
| cable_requirements |
—
|
| commissioning |
—
|
| installation_angle |
—
|
| mounting_clearances |
—
|
| torque |
—
|
Environment
| ingress_protection |
IP20 (module)
|
| max_altitude_m |
—
|
| operating_temperature_c |
charge 2°C ~ 57°C; discharge -18°C~57°C
|
| pollution_degree |
—
|
| protective_class |
—
|
| relative_humidity_pct |
—
|
| storage_temperature_c |
—
|
Interfaces & connectors
| app |
—
|
| communication |
['RS485', 'CAN', 'Dry Contact', 'WiFi']
|
| dry_contact |
—
|
| meter_interface |
—
|
| monitoring_portal |
—
|
| protocols |
[]
|
Protection
| anti_islanding |
—
|
| arc_fault |
—
|
| dc_switch |
—
|
| insulation_monitoring |
—
|
| overvoltage_category |
—
|
| rcmu |
—
|
| reverse_polarity |
—
|
| surge_protection_ac |
—
|
| surge_protection_dc |
—
|
Certifications
| standards |
['UN38.3', 'CE', 'UL1973', 'UL9540A', 'UL9540', 'IEC62619', 'SGIP']
|
Warranty & service
| conditions |
Cycle life ≥6000 Cycles; calendar life ≥10 Years (as printed)
|
| extension_options |
—
|
| standard_years |
—
|
Additional documented parameters
Recorded verbatim from the source; no schema field exists for these yet.
| document_demoted_to_mirror | https://www.pytesess.com/public/upload/20250821/52076beb0f72d3d7ee0529fdee9b0762.pdf |
| source_confidence_as_researched | officially-verified |