ANMASystem BuildingAutomation, Network, Monitoring & Analytics
PREMIUM

Knowledge BaseBatteries

SolaX Power T-BAT-SYS-HV-S3.6 (TP-HS36 stack)

Official manufacturer EU/global verified Sept. 1, 2026

Identity

category batteries
ean UNKNOWN
generation HS36
manufacturer SolaX Power
market_version EN datasheet V1.9; user manual Version 16.0
model T-BAT-SYS-HV-S3.6 (TP-HS36 stack)
mpn TP-HS36
note distinct from the already-recorded Triple Power T-BAT-SYS-HV 5.8 (T58): the HS36 line uses 3.6 kWh / 102.4 V modules with a TBMS-MCS0800 BMS and scales to 13 modules
product_family T-BAT-SYS-HV-S2.5 (TP-HS25) / T-BAT-SYS-HV-S3.6 (TP-HS36)
product_status active
region EU/global
release_year UNKNOWN
sku TP-HS36 (module)

Electrical

chemistry LFP (LiFePO4)
communication_can True
communication_rs485 True
firmware_requirements BMS Software V2.01; Battery Module Software V2.01 (user manual)
max_continuous_charge_current_a 35 (recommended) / 50 (maximum)
High-voltage Battery System T-BAT-SYS-HV-S3.6 7.37 kWh ~ 47.92 kWh Datasheet — 'Max continuous current: 35 A recommended / 50 A maximum'
max_continuous_discharge_current_a 35 (recommended) / 50 (maximum)
max_continuous_power_kw UNKNOWN (not printed)
max_parallel_units supported via multiple BMS units (count not stated in the fetched documents)
max_series_units 13 total modules; maximum 10 per single tower - beyond 10 modules a Series Box is required to connect two towers in series
min_series_units_hv 2
nominal_energy_kwh 7.37-47.92 (2-13 modules of 3.6 kWh)
nominal_voltage_v 102.4 per TP-HS36 module; stack nominal = N x 102.4 (N = 2-13)
officially_supported_inverter_brands ['SolaX Power']
officially_supported_inverter_models UNKNOWN (neither the datasheet V1.9 nor the user manual names inverter models; the manual only describes the BMS-to-inverter BAT+/BAT-/BMS port wiring)
peak_current_a UNKNOWN (not printed)
supported_inverter_protocols ['CAN2.0', 'RS485']
usable_energy_kwh 7.37-47.92 usable per datasheet headline (90 % DoD stated separately in the spec table)
voltage_class HV
voltage_range_v UNKNOWN per stack size. Datasheet V1.9 tabulates a 90-116 V d.c. window at module level; the manual quotes an overall system range of 90-750 V d.c. across all configurations

Physical / mechanical

bms_dimensions_mm 510 x 157 x 365
bms_weight_kg 13 +/- 0.5
cable_entry_positions UNKNOWN
depth_mm 365
height_mm stack height = 152 mm per module + 157 mm BMS + base
module_dimensions_mm 510 x 152 x 365
module_energy_kwh 3.6
module_nominal_voltage_v 102.4
module_weight_kg 34 +/- 1
mounting_bolt_size expansion bolts, minimum diameter 10 mm, embedded depth >= 50 mm; M4x14 and M4x10 Phillips screws; M6 flange nuts
mounting_type ['floor']
terminal_locations BAT+ / BAT- / BMS port on the TBMS-MCS0800 BMS unit
torque_specs M4x14 battery-mounting screws 0.9-1.1 N.m; M4x10 bracket screws 0.9-1.1 N.m; M6 flange nuts (bracket) 5 N.m; grounding terminal 4.5-5 N.m; self-tapping wall screws 4 N.m
T-BAT-SYS-HV-S2.5 / T-BAT-SYS-HV-S3.6 User Manual Version 16.0 — mechanical installation chapter, fastener torque table
weight_kg 34 (+/-1) per TP-HS36 module; 13 (+/-0.5) for the TBMS-MCS0800 BMS
width_mm 510

Installation

clearance_between_towers_mm 400-800
clearance_left_mm 400
clearance_rear_mm 30-200 (60 recommended)
clearance_right_mm 400
clearance_top_mm 100
indoor_outdoor indoor or outdoor (IP65); 'Avoid direct sunlight'
installation_humidity_range 5-95 % RH
max_installation_altitude_m 3000
maximum_modules_per_stack 10
T-BAT-SYS-HV-S2.5 / T-BAT-SYS-HV-S3.6 User Manual Version 16.0 — 'Maximum: 10 battery modules per single tower'
maximum_stacks_in_parallel UNKNOWN (parallel connection via multiple BMS units is supported)
minimum_modules_per_stack 2
mounting_orientation upright tower on a base, secured to the wall with an L-bracket and adjustable bracket
orientation_allowed ['floor tower with wall bracket']
parallel_rules 'If the battery module users purchased excesses 11 sets (including 11), a Series Box needs to be installed to connect two towers in series.' Maximum configuration 13 modules = 47.92 kWh.
T-BAT-SYS-HV-S2.5 / T-BAT-SYS-HV-S3.6 User Manual Version 16.0 — 'If the battery module users purchased excesses 11 sets (including 11), a Series Box needs to be installed to connect two towers in series.'
seismic_anchoring L-bracket + adjustable bracket with M6 flange nuts (5 N.m), expansion bolts >= 10 mm diameter and >= 50 mm depth
surface_requirements 'the bearing capacity of the ground ... must be over 500 kg/m2'
two_person_lift_required UNKNOWN (34 kg per module)

Environment

charge_temperature_c -30 to +53 (with heating); charge current reduced 0 to +25 and +45 to +53
cooling_method natural convection with integrated heating film
discharge_temperature_c -30 to +53 (with heating); discharge current reduced -20 to +10 and +45 to +53
ik_rating UNKNOWN
ip_rating IP65
max_altitude_m 3000
nema_rating UNKNOWN
noise_level_db UNKNOWN
operating_temperature_c -30 to +53 with heating; -20 to +53 discharge without heating
relative_humidity 4-100 % RH (datasheet); 5-95 % RH (manual)
storage_temperature_c -20 to +30 (12 months); +30 to +50 (6 months)

Interfaces & connectors

battery_terminal_type hot-plug power connectors with white lock buttons; DC cable 8.5-9.5 mm2 recommended at 50 A rated current; optional RNB14-5 ring terminals (10 mm2 grounding) and Phoenix male/female terminals
can yes (CAN2.0)
dry_contacts UNKNOWN
ethernet no (RJ45 carries the BMS bus)
grounding RNB5-6 terminal, 4-6 mm2 wire, heat-shrink tubing 28-30 mm
protocol_notes RJ45 8-pin BMS bus: GND, GND, BMS_H, BMS_L, 12V, A1, B1. DIP switch 4 sets the terminating resistor: open (down) for a single BMS or the last unit in a parallel chain, closed (up) for non-terminal parallel BMS units. Shielded cable required.
rs485 yes

Controls & display

audible_alarm UNKNOWN
buttons POWER button (>0.5 s start, >1 s shutdown, >5 s inverter startup mode, >20 s black start) and a rotary SWITCH (ON/OFF, lockable variant with ON/OFF/OFF+LOCK key lock)
display_type none (LED indicators only)
leds status indicator (solid green normal, solid red fault for >=10 min then 1 s on / 4 s off, yellow flash warning) plus four SOC indicators SOC1-SOC4
local_display False
mobile_app SolaX Cloud / SolaXCloud app (via inverter)
touchscreen False

Protection

fire_guidance 'keep a Class ABC fire extinguisher or a carbon dioxide extinguisher near the equipment'; 'If the battery module catches fire, please do not try to put out the fire, and evacuate immediately.'
integrated_breakers_fuses integrated DC fuse - 'Component Type DC Fuse; Fuse Type EV / HEV; Rated Voltage 750 Vdc/Vac; Rated Current 60 A'
T-BAT-SYS-HV-S2.5 / T-BAT-SYS-HV-S3.6 User Manual Version 16.0 — DC fuse specification table, 750 Vdc / 60 A
integrated_dc_switch rotary SWITCH on the BMS (not a breaker)
over_current yes (BMS_ChargeOverCurrent / BMS_DischargeOverCurrent faults at the 50 A limit)
over_temperature yes (BMS_TemHigh / BMS_TemLow, with current derating bands)
over_voltage yes (single-cell overvoltage monitoring)
short_circuit yes (DC fuse)
thermal_runaway_measures 'Do not dispose of the battery module in a fire'; 'The battery module may catch fire when heated above 302 F'
under_voltage yes

Certifications

emc []
grid_codes []
other ['UN38.3', 'UL9540A']
regional ['CE']
safety ['IEC62619', 'IEC60730', 'IEC62040']

Warranty & service

conditions recharge at least once every 12 months when stored at -20 to +30 C, or every 6 months at +30 to +50 C; minimum 50 % SOC if unused for more than 9 months
cycle_life > 6000 cycles
design_life_years UNKNOWN
standard_years UNKNOWN (not printed on datasheet V1.9 or the official product page)
throughput_guarantee_mwh UNKNOWN

Packaging & logistics

gross_weight_kg UNKNOWN
transport_restrictions 'UN number UN 3480; Hazardous materials classification Class 9; UN transportation testing requirements UN 38.3'
T-BAT-SYS-HV-S2.5 / T-BAT-SYS-HV-S3.6 User Manual Version 16.0 — transport chapter, UN 3480 / Class 9 / UN 38.3

Documents

datasheet High-voltage Battery System T-BAT-SYS-HV-S3.6 7.37 kWh ~ 47.92 kWh Datasheet rev V1.9
installation-manual T-BAT-SYS-HV-S2.5 / T-BAT-SYS-HV-S3.6 User Manual Version 16.0 rev Version 16.0
product-page SolaX HS36 official product page rev UNKNOWN

Additional documented parameters

Recorded verbatim from the source; no schema field exists for these yet.

Black startPOWER button held > 20 s
DC fuseEV/HEV type, 750 Vdc/Vac, 60 A
DIP switch 4 (terminating resistor)open for single/last BMS, closed for non-terminal parallel BMS
Ground bearing capacitymust be over 500 kg/m2
Series Boxrequired for >= 11 modules to series-connect two towers